← Commit history

nvf5p03t3g: specified limits as data (metadata.characteristics, 39 rows from the datasheet)

Ray ·4b06dad982 ·25d ago ·parent fde518e
2 files changed +522−1
README.md+46
@@ -28,6 +28,52 @@ Same part, different packaging or reel option.  - `NVF5P03T3G` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-to-Source Voltage | VDSS |  |  | -30 | V |  | 2 |+| Drain-to-Gate Voltage | VDGR |  |  | -30 | V | RGS = 1.0 M | 2 |+| Gate-to-Source Voltage - Continuous | VGS | -20 |  | 20 | V |  | 2 |+| Thermal Resistance - Junction to Ambient | RTHJA |  |  | 40 | °C/W | 1 sq in FR-4 or G-10 PCB, 10 seconds | 2 |+| Total Power Dissipation @ TA = 25°C | PD |  |  | 3.13 | Watts | TA = 25°C, 1 sq in FR-4 or G-10 PCB, 10 seconds | 2 |+| Linear Derating Factor | PD |  |  | 25 | mW/°C | 1 sq in FR-4 or G-10 PCB, 10 seconds | 2 |+| Drain Current - Continuous @ TA = 25°C | ID |  |  | -5.2 | A | TA = 25°C, 1 sq in FR-4 or G-10 PCB, 10 seconds | 2 |+| Drain Current - Continuous @ TA = 70°C | ID |  |  | -4.1 | A | TA = 70°C, 1 sq in FR-4 or G-10 PCB, 10 seconds | 2 |+| Pulsed Drain Current | IDM |  |  | -26 | A | 1 sq in FR-4 or G-10 PCB, 10 seconds; Note 1 | 2 |+| Thermal Resistance - Junction to Ambient (minimum pad) | RTHJA |  |  | 80 | °C/W | Minimum FR-4 or G-10 PCB, 10 seconds | 2 |+| Total Power Dissipation @ TA = 25°C (minimum pad) | PD |  |  | 1.56 | Watts | TA = 25°C, Minimum FR-4 or G-10 PCB, 10 seconds | 2 |+| Linear Derating Factor (minimum pad) | PD |  |  | 12.5 | mW/°C | Minimum FR-4 or G-10 PCB, 10 seconds | 2 |+| Drain Current - Continuous @ TA = 25°C (minimum pad) | ID |  |  | -3.7 | A | TA = 25°C, Minimum FR-4 or G-10 PCB, 10 seconds | 2 |+| Drain Current - Continuous @ TA = 70°C (minimum pad) | ID |  |  | -2.9 | A | TA = 70°C, Minimum FR-4 or G-10 PCB, 10 seconds | 2 |+| Pulsed Drain Current (minimum pad) | IDM |  |  | -19 | A | Minimum FR-4 or G-10 PCB, 10 seconds; Note 1 | 2 |+| Operating and Storage Temperature Range | TJ, Tstg | -55 |  | 150 | °C |  | 2 |+| Single Pulse Drain-to-Source Avalanche Energy - Starting TJ = 25°C | EAS |  |  | 250 | mJ | VDD = −30 Vdc, VGS = −10 Vdc, Peak IL = −12 Apk, L = 3.5 mH, RG = 25 | 2 |+| Drain-to-Source Breakdown Voltage | V(BR)DSS | -30 |  |  | Vdc | VGS = 0 Vdc, ID = −250 Adc | 3 |+| Zero Gate Voltage Drain Current | IDSS |  |  | -1 | Adc | VDS = −24 Vdc, VGS = 0 Vdc | 3 |+| Zero Gate Voltage Drain Current | IDSS |  |  | -25 | Adc | VDS = −24 Vdc, VGS = 0 Vdc, TJ = 125°C | 3 |+| Gate-Body Leakage Current | IGSS | -100 |  | 100 | nAdc | VGS = ± 20 Vdc, VDS = 0 Vdc | 3 |+| Gate Threshold Voltage | VGS(th) | -1 | -1.75 | -3 | Vdc | VDS = VGS, ID = −250 Adc | 3 |+| Static Drain-to-Source On-Resistance | RDS(on) |  | 76 | 107 | m | VGS = −10 Vdc, ID = −5.2 Adc | 3 |+| Static Drain-to-Source On-Resistance | RDS(on) |  | 100 | 150 | m | VGS = −4.5 Vdc, ID = −2.6 Adc | 3 |+| Forward Transconductance | gfs | 2 | 3.9 |  | Mhos | VDS = −15 Vdc, ID = −2.0 Adc | 3 |+| Input Capacitance | Ciss |  | 500 | 950 | pF | VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz | 3 |+| Output Capacitance | Coss |  | 153 | 440 | pF | VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz | 3 |+| Transfer Capacitance | Crss |  | 58 | 140 | pF | VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz | 3 |+| Turn-On Delay Time | td(on) |  | 10 | 24 | ns | VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Rise Time | tr |  | 33 | 48 | ns | VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Turn-Off Delay Time | td(off) |  | 38 | 94 | ns | VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Fall Time | tf |  | 20 | 92 | ns | VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Turn-On Delay Time | td(on) |  | 16 | 38 | ns | VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Rise Time | tr |  | 45 | 110 | ns | VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Turn-Off Delay Time | td(off) |  | 23 | 60 | ns | VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Fall Time | tf |  | 24 | 80 | ns | VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2) | 3 |+| Total Gate Charge | QT |  | 15 | 38 | nC | VDS = −24 Vdc, ID = −4.0 Adc, VGS = −10 Vdc (Note 2) | 3 |+| Forward On-Voltage | VSD |  |  | -1.1 | Vdc | IS = −4.0 Adc, VGS = 0 Vdc | 3 |+| Forward On-Voltage | VSD |  | -0.89 | -1.5 | Vdc | IS = −4.0 Adc, VGS = 0 Vdc, TJ = 125°C (Note 2) | 3 |+ ## CAD (KiCad official)  - Symbol: `NVF5P03T3G`
page.json+476−1
@@ -80,6 +80,481 @@       "Package": "SOT-223-3",       "Category": "Transistors/Thyristors",       "Pins": "4"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "14001d34020757a1",+      "rows": [+        {+          "name": "Drain-to-Source Voltage",+          "symbol": "VDSS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": -30,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-to-Gate Voltage",+          "symbol": "VDGR",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": -30,+          "conditions": "RGS = 1.0 M",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Source Voltage - Continuous",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance - Junction to Ambient",+          "symbol": "RTHJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "1 sq in FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Power Dissipation @ TA = 25°C",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "Watts",+          "min": null,+          "typ": null,+          "max": 3.13,+          "conditions": "TA = 25°C, 1 sq in FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Linear Derating Factor",+          "symbol": "PD",+          "kind": "thermal",+          "unit": "mW/°C",+          "min": null,+          "typ": null,+          "max": 25,+          "conditions": "1 sq in FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain Current - Continuous @ TA = 25°C",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -5.2,+          "conditions": "TA = 25°C, 1 sq in FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain Current - Continuous @ TA = 70°C",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -4.1,+          "conditions": "TA = 70°C, 1 sq in FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Drain Current",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -26,+          "conditions": "1 sq in FR-4 or G-10 PCB, 10 seconds; Note 1",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance - Junction to Ambient (minimum pad)",+          "symbol": "RTHJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "Minimum FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Power Dissipation @ TA = 25°C (minimum pad)",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "Watts",+          "min": null,+          "typ": null,+          "max": 1.56,+          "conditions": "TA = 25°C, Minimum FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Linear Derating Factor (minimum pad)",+          "symbol": "PD",+          "kind": "thermal",+          "unit": "mW/°C",+          "min": null,+          "typ": null,+          "max": 12.5,+          "conditions": "Minimum FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain Current - Continuous @ TA = 25°C (minimum pad)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -3.7,+          "conditions": "TA = 25°C, Minimum FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain Current - Continuous @ TA = 70°C (minimum pad)",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -2.9,+          "conditions": "TA = 70°C, Minimum FR-4 or G-10 PCB, 10 seconds",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Drain Current (minimum pad)",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -19,+          "conditions": "Minimum FR-4 or G-10 PCB, 10 seconds; Note 1",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating and Storage Temperature Range",+          "symbol": "TJ, Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Single Pulse Drain-to-Source Avalanche Energy - Starting TJ = 25°C",+          "symbol": "EAS",+          "kind": "absolute_maximum",+          "unit": "mJ",+          "min": null,+          "typ": null,+          "max": 250,+          "conditions": "VDD = −30 Vdc, VGS = −10 Vdc, Peak IL = −12 Apk, L = 3.5 mH, RG = 25",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-to-Source Breakdown Voltage",+          "symbol": "V(BR)DSS",+          "kind": "electrical",+          "unit": "Vdc",+          "min": -30,+          "typ": null,+          "max": null,+          "conditions": "VGS = 0 Vdc, ID = −250 Adc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Zero Gate Voltage Drain Current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "Adc",+          "min": null,+          "typ": null,+          "max": -1,+          "conditions": "VDS = −24 Vdc, VGS = 0 Vdc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Zero Gate Voltage Drain Current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "Adc",+          "min": null,+          "typ": null,+          "max": -25,+          "conditions": "VDS = −24 Vdc, VGS = 0 Vdc, TJ = 125°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate-Body Leakage Current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nAdc",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VGS = ± 20 Vdc, VDS = 0 Vdc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Gate Threshold Voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "Vdc",+          "min": -1,+          "typ": -1.75,+          "max": -3,+          "conditions": "VDS = VGS, ID = −250 Adc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-to-Source On-Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "m",+          "min": null,+          "typ": 76,+          "max": 107,+          "conditions": "VGS = −10 Vdc, ID = −5.2 Adc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-to-Source On-Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "m",+          "min": null,+          "typ": 100,+          "max": 150,+          "conditions": "VGS = −4.5 Vdc, ID = −2.6 Adc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Forward Transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "Mhos",+          "min": 2,+          "typ": 3.9,+          "max": null,+          "conditions": "VDS = −15 Vdc, ID = −2.0 Adc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input Capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 500,+          "max": 950,+          "conditions": "VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output Capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 153,+          "max": 440,+          "conditions": "VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Transfer Capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 58,+          "max": 140,+          "conditions": "VDS = −25 Vdc, VGS = 0 V, f = 1.0 MHz",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 10,+          "max": 24,+          "conditions": "VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rise Time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 33,+          "max": 48,+          "conditions": "VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 38,+          "max": 94,+          "conditions": "VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Fall Time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 20,+          "max": 92,+          "conditions": "VDD = −15 Vdc, ID = −4.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 16,+          "max": 38,+          "conditions": "VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Rise Time",+          "symbol": "tr",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 45,+          "max": 110,+          "conditions": "VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 23,+          "max": 60,+          "conditions": "VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Fall Time",+          "symbol": "tf",+          "kind": "timing",+          "unit": "ns",+          "min": null,+          "typ": 24,+          "max": 80,+          "conditions": "VDD = −15 Vdc, ID = −2.0 Adc, VGS = −10 Vdc, RG = 6.0 (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Total Gate Charge",+          "symbol": "QT",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 15,+          "max": 38,+          "conditions": "VDS = −24 Vdc, ID = −4.0 Adc, VGS = −10 Vdc (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Forward On-Voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": -1.1,+          "conditions": "IS = −4.0 Adc, VGS = 0 Vdc",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Forward On-Voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "Vdc",+          "min": null,+          "typ": -0.89,+          "max": -1.5,+          "conditions": "IS = −4.0 Adc, VGS = 0 Vdc, TJ = 125°C (Note 2)",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [@@ -125,4 +600,4 @@     "public": true   },   "updated_at": "2026-09-25T03:22:33.083Z"-}\ No newline at end of file+}