  "component": {
    "mpn": "nSMD100",
    "manufacturer": "TECHFUSE",
    "package": "1206",
    "pin_count": 2,
    "category": "Circuit Protection",
    "subcategory": "Resettable Fuses",
    "datasheet": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8586175912668356608",
    "parts": {
      "symbol": "nsmd100.kicad_sym",
      "footprint": "nsmd100.kicad_mod",
      "model_3d": "nsmd100-hero.glb",
      "model_3d_plain": "nsmd100-etched.glb",
      "model_3d_step": "nsmd100-etched.step",
      "model_3d_step_plain": "nsmd100.step",
      "lbr": "nsmd100.lbr"
    },
    "distributor_links": {
      "lcsc": "C66453"
    },
    "distributor_check": {
      "checked_at": "2026-10-18T11:09:15Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": null,
        "status": "quota"
      },
      "mouser": {
        "pn": null,
        "status": "quota"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "1",
        "type": "passive",
        "description": "One of two interchangeable, non-polarized tin-plated nickel-copper terminations of the PPTC; rated Vmax 6.0 Vdc, Ihold 1.00 A, Itrip 1.80 A, Imax 100 A."
      },
      {
        "number": "2",
        "name": "2",
        "type": "passive",
        "description": "Second of two interchangeable, non-polarized tin-plated nickel-copper terminations of the PPTC; rated Vmax 6.0 Vdc, Ihold 1.00 A, Itrip 1.80 A, Imax 100 A."
      }
    ],
    "provenance": {
      "extractor": "extract_pins 0.3",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins 0.3",
        "primary_model": "claude-sonnet-5-5",
        "primary_mode": "text+vision",
        "consensus_model": "claude-opus-5-5",
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "extractor flagged: The datasheet drawing shows two end terminations and two solder pads (1.0 mm wide, 2.0 mm gap, 1.9 m; The 1206 package (3216 mm) comes from the package hint and the datasheet's 'Size 3216 mm / 1206 inch",
          "vision extraction: provenance cannot be text-verified; needs consensus"
        ],
        "pages_sent": 3,
        "cost_usd": 0.1218,
        "at": "2026-10-18T11:07:24"
      },
      "datasheet": {
        "url": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8586175912668356608",
        "pages": 3,
        "sha256": "986063e150e61039",
        "source_tier": "lcsc"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 2,
        "described": 2,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "nsmd100.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          3.2,
          1.6,
          0.55
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "5e6dcbe286696143d35a8ea37d91eef4b54ff3d1bd7c2c2b4dedda83d3f8e203",
        "checked": "2026-10-18",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "nsmd100-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          3.2,
          1.6,
          0.55
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "61203c74def8ba49f8983e916c7df8476aa5ec3e70851c2a8614409ede9ab321",
        "checked": "2026-10-18",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "specs": {
      "Manufacturer": "TECHFUSE",
      "Package": "1206",
      "Category": "Circuit Protection",
      "Pins": "2"
    },
    "appearance": {
      "contacts": {
        "quote": "Terminal pad materials: Tin-plated Nickel-Copper",
        "page": 2,
        "doc": "ds.pdf",
        "material": "Copper",
        "plating": "tin"
      },
      "version": 1,
      "datasheet_sha256": "986063e150e610391436a6d903fd7fd7acad2d0b0aeb4e52c29c5a43314cb00f"
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "986063e150e610391436a6d903fd7fd7acad2d0b0aeb4e52c29c5a43314cb00f",
      "rows": [
        {
          "name": "Minimum device resistance prior to tripping (Rimin)",
          "symbol": "Rimin",
          "kind": "electrical",
          "unit": "Ω",
          "min": 0.055,
          "typ": null,
          "max": null,
          "conditions": "25°C still air, prior to tripping",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum device resistance one hour post reflow (R1max)",
          "symbol": "R1max",
          "kind": "electrical",
          "unit": "Ω",
          "min": null,
          "typ": null,
          "max": 0.27,
          "conditions": "measured one hour post reflow",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current (Ihold)",
          "symbol": "Ihold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 1,
          "conditions": "25°C still air; maximum current device will not trip",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Trip current (Itrip)",
          "symbol": "Itrip",
          "kind": "electrical",
          "unit": "A",
          "min": 1.8,
          "typ": null,
          "max": null,
          "conditions": "25°C still air; minimum current at which device will always trip",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum operating voltage (Vmax)",
          "symbol": "Vmax",
          "kind": "absolute_maximum",
          "unit": "Vdc",
          "min": null,
          "typ": null,
          "max": 6,
          "conditions": "at rated current (Imax)",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum fault current (Imax)",
          "symbol": "Imax",
          "kind": "absolute_maximum",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 100,
          "conditions": "at rated voltage (Vmax)",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Power dissipation in tripped state (Pd)",
          "symbol": "Pd",
          "kind": "electrical",
          "unit": "W",
          "min": null,
          "typ": 0.6,
          "max": null,
          "conditions": "tripped state, 25°C still air, at rated voltage",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Max. Current (table column)",
          "symbol": "",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": 8,
          "max": null,
          "conditions": "table column 'Max. Current' paired with 'Time' 0.30 Sec",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Time (table column)",
          "symbol": "",
          "kind": "electrical",
          "unit": "Sec",
          "min": null,
          "typ": 0.3,
          "max": null,
          "conditions": "table column 'Time' paired with 'Max. Current' 8.00 A",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Passive aging resistance change",
          "symbol": "",
          "kind": "electrical",
          "unit": "%",
          "min": -5,
          "typ": null,
          "max": 5,
          "conditions": "+85°C, 1000 hrs; printed ±5% typical",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Humidity aging resistance change",
          "symbol": "",
          "kind": "electrical",
          "unit": "%",
          "min": -5,
          "typ": null,
          "max": 5,
          "conditions": "+85°C, 85% R.H., 168 hours; printed ±5% typical",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Thermal shock resistance change",
          "symbol": "",
          "kind": "electrical",
          "unit": "%",
          "min": -33,
          "typ": null,
          "max": 33,
          "conditions": "+85°C to -40°C, 20 times; printed ±33% typical",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Ambient operating temperature",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 85,
          "conditions": "ambient operating conditions",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum surface temperature in tripped state",
          "symbol": "",
          "kind": "thermal",
          "unit": "°C",
          "min": null,
          "typ": null,
          "max": 125,
          "conditions": "device in tripped state",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 1.45,
          "max": null,
          "conditions": "ambient -40°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 1.31,
          "max": null,
          "conditions": "ambient -20°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 1.15,
          "max": null,
          "conditions": "ambient 0°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 1,
          "max": null,
          "conditions": "ambient 25°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 0.84,
          "max": null,
          "conditions": "ambient 40°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 0.77,
          "max": null,
          "conditions": "ambient 50°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 0.69,
          "max": null,
          "conditions": "ambient 60°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 0.61,
          "max": null,
          "conditions": "ambient 70°C",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Hold current vs ambient temperature",
          "symbol": "Ihold",
          "kind": "temperature_coefficient",
          "unit": "A",
          "min": null,
          "typ": 0.48,
          "max": null,
          "conditions": "ambient 85°C",
          "source_page": 1,
          "source": "datasheet"
        }
      ]
    }
  },
  "variants": [],
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "nsmd100"
  ],
  "discovery_pitch": "nSMD100 (TECHFUSE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "author": {
    "name": "Ray",
    "email": "[email protected]"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "nsmd100.kicad_sym",
    "nsmd100.kicad_mod",
    "nsmd100.glb",
    "nsmd100.step",
    "nsmd100.lbr",
    "docs/hero.png",
    "docs/nsmd100-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "nsmd100-hero.glb",
    "nsmd100-hero.overlay.json",
    "nsmd100-etched.glb"
  ],
  "visibility": {
    "public": true
  }
}