main
Ray
Publish 0.1.1
718f1c4
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211
{
"slug": "ncv7341d21r2g",
"version": "0.1.1",
"type": "component",
"description": "onsemi CAN Controllers, SOIC-14. Datasheet-verified pinout, KiCad symbol/footprint/3D.",
"tags": [
"component",
"interface",
"ncv7341d21r2g"
],
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"ncv7341d21r2g.kicad_sym",
"ncv7341d21r2g.kicad_mod",
"ncv7341d21r2g.glb",
"ncv7341d21r2g.step",
"ncv7341d21r2g.lbr",
"docs/hero.png",
"docs/ncv7341d21r2g-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"ncv7341d21r2g-etched.step",
"ncv7341d21r2g-etched.glb"
],
"visibility": "public",
"author": {
"name": "Ray"
},
"component": {
"mpn": "NCV7341D21R2G",
"manufacturer": "onsemi",
"package": "SOIC-14",
"pin_count": 14,
"category": "CAN Controllers",
"datasheet": "https://www.onsemi.com/pdf/datasheet/ncv7341d21r2-d.pdf",
"parts": {
"symbol": "ncv7341d21r2g.kicad_sym",
"footprint": "ncv7341d21r2g.kicad_mod",
"model_3d": "ncv7341d21r2g-etched.glb",
"model_3d_plain": "ncv7341d21r2g.glb",
"model_3d_step": "ncv7341d21r2g-etched.step",
"model_3d_step_plain": "ncv7341d21r2g.step",
"lbr": "ncv7341d21r2g.lbr"
},
"pins": [
{
"number": "1",
"name": "TxD",
"type": "input",
"description": "Transmit data input from the CAN controller. Low level drives a dominant state on the bus; has an internal pull-up current so the pin defaults high (recessive) if disconnected. A TxD dominant time-out disables the transmitter after tdom(TxD) = 300-1000 us to prevent bus lockup."
},
{
"number": "2",
"name": "GND",
"type": "power_in",
"description": "Ground reference for the device. All voltages in the datasheet are referenced to GND (Pin 2)."
},
{
"number": "3",
"name": "VCC",
"type": "power_in",
"description": "Supply voltage for the core circuitry and the CAN transceiver output stage. Operating range 4.75 V to 5.25 V; absolute max +7 V."
},
{
"number": "4",
"name": "RxD",
"type": "output",
"description": "Receive data output to the CAN controller. Dominant bus state produces a low output; recessive bus state produces a high output. Output levels are referenced to VIO for controller interface flexibility."
},
{
"number": "5",
"name": "VIO",
"type": "power_in",
"description": "Supply voltage for the digital interface to the CAN controller / microcontroller, allowing interfacing to controllers with 3 V or 5 V I/O. Operating range 2.8 V to 5.25 V; absolute max +7 V."
},
{
"number": "6",
"name": "EN",
"type": "input",
"description": "Enable / mode-control input (together with STB selects Normal, Receive-only, Standby, Go-to-Sleep, or Sleep modes). Has an internal pull-down current so pin defaults low if disconnected. Levels referenced to VIO."
},
{
"number": "7",
"name": "INH",
"type": "output",
"description": "High-voltage inhibit output for controlling external voltage regulators. Pulled high (near VBAT, with typ 200 mV drop at 180 uA) in Normal/Receive-only/Standby/Go-to-Sleep modes; floats in Sleep mode to switch off the external regulators. Rated up to VBAT+0.3 V."
},
{
"number": "8",
"name": "ERR",
"type": "output",
"description": "Active-low digital output that indicates internal flag conditions (power-up, wake-up, failure, and bus failure on the D20 version). Uses negative logic - pulled low when a signaled flag is set. Levels referenced to VIO."
},
{
"number": "9",
"name": "WAKE",
"type": "input",
"description": "Local wake-up input. A stable High-to-Low or Low-to-High transition longer than tWAKE (5-50 us) is detected as a local wake-up event in Standby/Go-to-Sleep/Sleep modes. Internal current source (~5 uA pull-up or pull-down following the pin state). Rated up to 58 V; connect to GND or VBAT if unused."
},
{
"number": "10",
"name": "VBAT",
"type": "power_in",
"description": "Battery supply connection (12 V or 24 V systems). Operating range 5 V to 50 V (6 V to 50 V guaranteed in Sleep mode); absolute max 58 V. Supplies the low-power wake circuitry and the INH output."
},
{
"number": "11",
"name": "VSPLIT",
"type": "output",
"description": "Common-mode stabilization output providing VCC/2 (0.3*VCC to 0.7*VCC) in Normal and Receive-only modes for use with split termination to reduce EME. High-impedance (floating) in Standby and Sleep modes. Protected against short-circuit to battery/ground; rated -58 V to +58 V DC and +/-300 V transient."
},
{
"number": "12",
"name": "CANL",
"type": "bidirectional",
"description": "Low-level CAN bus line (driven low in dominant state, typ 1.4 V). Differential pair with CANH; rated -58 V to +58 V DC and +/-300 V transient (ISO 7637). Short-circuit protected and thermally protected."
},
{
"number": "13",
"name": "CANH",
"type": "bidirectional",
"description": "High-level CAN bus line (driven high in dominant state, typ 3.6 V). Differential pair with CANL; rated -58 V to +58 V DC and +/-300 V transient (ISO 7637). Short-circuit protected and thermally protected."
},
{
"number": "14",
"name": "STB",
"type": "input",
"description": "Active-low stand-by mode control input (together with EN selects operating mode). Has an internal pull-down current so pin defaults low if disconnected. Levels referenced to VIO."
}
],
"provenance": {
"rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction",
"cad": "KiCad official (CC-BY-SA 4.0)",
"cad_basis": {
"from": [
"README CAD section (factory cad_wording)",
".kicad_mod model path agrees"
],
"missing": []
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"distributor_links": {
"lcsc": "C559409",
"digikey": "NCV7341D21R2GOSTR-ND",
"mouser": "863-NCV7341D21R2G"
},
"distributor_check": {
"checked_at": "2026-10-05T19:11:54Z",
"source": "Component Ocean /api/assign-pns + lcsc_map",
"digikey": {
"pn": "NCV7341D21R2GOSTR-ND",
"status": "found"
},
"mouser": {
"pn": "863-NCV7341D21R2G",
"status": "found"
}
},
"models_3d": [
{
"file": "ncv7341d21r2g.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
8.7,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "3b9a775da256c8afcc28dcddfbc2eb3f266107fe61ce8446d96f2c52b6f44a70",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "ncv7341d21r2g-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
8.7,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "0d384746613654b91b3a2247c30d733dd2239fb9636ce3e3e01f9b9adac2074f",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"org": "adom"
}