← Commit history
package.json+375−4@@ -1,6 +1,6 @@ { "slug": "mp6400dj-01-lf-z",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Monolithic Power Systems Monitors & Reset Circuits, TSOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "mp6400dj-01-lf-z-hero.glb", "mp6400dj-01-lf-z-hero.overlay.json",- "mp6400dj-01-lf-z-etched.glb"+ "mp6400dj-01-lf-z-etched.glb",+ "mp6400dj-01-lf-z-etched.step" ], "component": { "mpn": "MP6400DJ-01-LF-Z",@@ -43,7 +44,7 @@ "symbol": "mp6400dj-01-lf-z.kicad_sym", "footprint": "mp6400dj-01-lf-z.kicad_mod", "model_3d": "mp6400dj-01-lf-z-hero.glb",- "model_3d_plain": "mp6400dj-01-lf-z-etched.glb",+ "model_3d_plain": "mp6400dj-01-lf-z.glb", "model_3d_step": "mp6400dj-01-lf-z-etched.step", "model_3d_step_plain": "mp6400dj-01-lf-z.step", "lbr": "mp6400dj-01-lf-z.lbr"@@ -179,5 +180,375 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "MP6400DJ-01-LF-Z",+ "brief": "Monolithic Power Systems Monitors & Reset Circuits, TSOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Monolithic Power Systems",+ "Package": "TSOT-23-6",+ "Category": "Power Management",+ "Pins": "6"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "0d075db4e48b0d2d05e78ddc83ce92b358315e180c8e36180422a2eab8377fe8",+ "rows": [+ {+ "name": "Input Supply Range",+ "symbol": "VCC",+ "kind": "electrical",+ "unit": "V",+ "min": 1.8,+ "typ": null,+ "max": 6,+ "conditions": "1.8V≤VCC≤6V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply Current",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 1.6,+ "max": 3.5,+ "conditions": "VCC = 3.3V, RESET not asserted, MR, RESET, CDELAY open",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply Current",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 1.85,+ "max": 12,+ "conditions": "VCC = 6V, RESET not asserted, MR, RESET, CDELAY open",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Low-level Output Voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.3,+ "conditions": "1.3V ≤ VCC < 1.8V, IOL = 0.4mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Low-level Output Voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.4,+ "conditions": "1.8V ≤ VCC ≤ 6V, IOL = 1.0mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Power-up Reset Voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.8,+ "conditions": "VOL (max) = 0.2V, IRESET = 15uA, Trise(Vcc)≥15µs/V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Negative-going Input Threshold Accuracy",+ "symbol": "VIT",+ "kind": "electrical",+ "unit": "%",+ "min": -2,+ "typ": 1,+ "max": 2,+ "conditions": "VSENSE falling slowly",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hysteresis on VIT Pin",+ "symbol": "VHYS",+ "kind": "electrical",+ "unit": "VIT%",+ "min": 1.5,+ "typ": null,+ "max": 3.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "MR Internal Pull-up Resistance",+ "symbol": "RMR",+ "kind": "electrical",+ "unit": "kΩ",+ "min": 50,+ "typ": null,+ "max": 110,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Current at SENSE Pin",+ "symbol": "ISENSE",+ "kind": "electrical",+ "unit": "nA",+ "min": -25,+ "typ": null,+ "max": 25,+ "conditions": "MP6400DJ-01, VSENSE = VIT",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "RESET Leakage Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "nA",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "VRESET = 6V, RESET not asserted",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "MR Logic Low Input",+ "symbol": "VIL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.25,+ "conditions": "0.25VCC",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "MR Logic High Input",+ "symbol": "VIH",+ "kind": "electrical",+ "unit": "V",+ "min": 0.7,+ "typ": null,+ "max": null,+ "conditions": "0.7VCC",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "SENSE Maximum Transient Duration",+ "symbol": "tw",+ "kind": "timing",+ "unit": "µs",+ "min": null,+ "typ": 17.5,+ "max": null,+ "conditions": "VIH = 1.05 VIT, VIL = 0.95 VIT",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "RESET Delay Time",+ "symbol": "td",+ "kind": "timing",+ "unit": "ms",+ "min": 15,+ "typ": 24,+ "max": 34,+ "conditions": "CDELAY = Open",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "RESET Delay Time",+ "symbol": "td",+ "kind": "timing",+ "unit": "ms",+ "min": 230,+ "typ": 380,+ "max": 530,+ "conditions": "CDELAY = VCC (guaranteed by design)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "RESET Delay Time",+ "symbol": "td",+ "kind": "timing",+ "unit": "ms",+ "min": 1.3,+ "typ": 2.1,+ "max": 3,+ "conditions": "CDELAY = 150pF",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "RESET Delay Time",+ "symbol": "td",+ "kind": "timing",+ "unit": "ms",+ "min": 61,+ "typ": 102,+ "max": 142,+ "conditions": "CDELAY = 10nF (guaranteed by design)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "MR to RESET Propagation Delay",+ "symbol": "tpHL1",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": 160,+ "max": null,+ "conditions": "VIH = 0.7 VCC, VIL = 0.25 VCC",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "High to Low Level RESET Delay, SENSE to RESET",+ "symbol": "tpHL2",+ "kind": "timing",+ "unit": "µs",+ "min": null,+ "typ": 17.5,+ "max": null,+ "conditions": "VIH = 1.05 VIT, VIL = 0.95 VIT",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage",+ "symbol": "VCC",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "SENSE Voltage",+ "symbol": "VSENSE",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "All Other Pins",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "RESET Current",+ "symbol": "IRESET",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 1.8,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance Junction to Case",+ "symbol": "θJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 110,+ "conditions": "TSOT23-6, JESD51-7 4-layer board",+ "source_page": 3,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "mp6400dj-01-lf-z"+ ],+ "discovery_pitch": "MP6400DJ-01-LF-Z (Monolithic Power Systems) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "mp6400dj-01-lf-z", "title": "MP6400DJ-01-LF-Z", "brief": "Monolithic Power Systems Monitors & Reset Circuits, TSOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "mp6400dj-01-lf-z.kicad_sym", "footprint": "mp6400dj-01-lf-z.kicad_mod", "model_3d": "mp6400dj-01-lf-z-hero.glb",- "model_3d_plain": "mp6400dj-01-lf-z-etched.glb",+ "model_3d_plain": "mp6400dj-01-lf-z.glb", "model_3d_step": "mp6400dj-01-lf-z-etched.step", "model_3d_step_plain": "mp6400dj-01-lf-z.step", "lbr": "mp6400dj-01-lf-z.lbr"@@ -560,9 +560,10 @@ "viewers/footprint.html", "mp6400dj-01-lf-z-hero.glb", "mp6400dj-01-lf-z-hero.overlay.json",- "mp6400dj-01-lf-z-etched.glb"+ "mp6400dj-01-lf-z-etched.glb",+ "mp6400dj-01-lf-z-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Monolithic Power Systems Monitors & Reset Circuits, TSOT-23-6. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }