package.json+663−4@@ -1,6 +1,6 @@ { "slug": "mp4059gs-z",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Monolithic Power Systems LED Drivers, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "mp4059gs-z-hero.glb", "mp4059gs-z-hero.overlay.json",- "mp4059gs-z-etched.glb"+ "mp4059gs-z-etched.glb",+ "mp4059gs-z-etched.step" ], "component": { "mpn": "MP4059GS-Z",@@ -43,7 +44,7 @@ "symbol": "mp4059gs-z.kicad_sym", "footprint": "mp4059gs-z.kicad_mod", "model_3d": "mp4059gs-z-hero.glb",- "model_3d_plain": "mp4059gs-z-etched.glb",+ "model_3d_plain": "mp4059gs-z.glb", "model_3d_step": "mp4059gs-z-etched.step", "model_3d_step_plain": "mp4059gs-z.step", "lbr": "mp4059gs-z.lbr"@@ -239,5 +240,663 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "MP4059GS-Z",+ "brief": "Monolithic Power Systems LED Drivers, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Monolithic Power Systems",+ "Package": "SOIC-8",+ "Category": "LED Drivers",+ "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "b86541f2fff2cf74826505975800e68f7bb88fa0eec870332ad814ffa3a20587",+ "rows": [+ {+ "name": "Operating range VCC",+ "symbol": "VCC",+ "kind": "electrical",+ "unit": "V",+ "min": 6,+ "typ": null,+ "max": 27,+ "conditions": "After turn on",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC LFM level: LFM is triggered",+ "symbol": "VCCLFM",+ "kind": "electrical",+ "unit": "V",+ "min": 7.95,+ "typ": 8.25,+ "max": 8.5,+ "conditions": "VCC falling edge",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC regulate value at CV",+ "symbol": "VCCregulate",+ "kind": "electrical",+ "unit": "V",+ "min": 7.1,+ "typ": 7.5,+ "max": 7.9,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC upper level: internal charging stops and IC turns on",+ "symbol": "VCCH",+ "kind": "electrical",+ "unit": "V",+ "min": 10,+ "typ": 10.5,+ "max": 11,+ "conditions": "VCC rising edge",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC lower level: internal charging circuit triggers",+ "symbol": "VCCL",+ "kind": "electrical",+ "unit": "V",+ "min": 5.2,+ "typ": 5.5,+ "max": 5.8,+ "conditions": "VCC falling edge",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC charging current from D",+ "symbol": "ID-charge",+ "kind": "electrical",+ "unit": "mA",+ "min": 3.7,+ "typ": 5.7,+ "max": 7.2,+ "conditions": "VD = 16V, VCC = 10.5V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating current, CC operation",+ "symbol": "Ioperating",+ "kind": "electrical",+ "unit": "µA",+ "min": 370,+ "typ": 440,+ "max": 620,+ "conditions": "Switch frequency is 60kHz, CC operation",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating current under fault condition",+ "symbol": "Ifault",+ "kind": "electrical",+ "unit": "µA",+ "min": 205,+ "typ": 265,+ "max": 360,+ "conditions": "Fault condition, IC latch, VCC = 15V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Pull-down current during UVLO",+ "symbol": "Ipull_down_UVLO",+ "kind": "electrical",+ "unit": "mA",+ "min": 0.85,+ "typ": 1.25,+ "max": 1.8,+ "conditions": "VCC = 5V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DIM high level",+ "symbol": "Vdim_H",+ "kind": "electrical",+ "unit": "V",+ "min": 1.08,+ "typ": 1.2,+ "max": 1.33,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "DIM low level",+ "symbol": "Vdim_L",+ "kind": "electrical",+ "unit": "V",+ "min": 0.26,+ "typ": 0.3,+ "max": 0.33,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum DIM detect time, to determine the frequency of PWM dimming signal",+ "symbol": "tdim_detect",+ "kind": "electrical",+ "unit": "ms",+ "min": 8,+ "typ": 9.4,+ "max": 12,+ "conditions": "PWM dimming frequency should be higher than 200Hz",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Feedback voltage",+ "symbol": "VFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.186,+ "typ": 0.193,+ "max": 0.2,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Max source current",+ "symbol": "ICOMP+",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "CC",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Max sink current",+ "symbol": "ICOMP-",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": -200,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Upper clamp voltage for CV",+ "symbol": "VCOMP_H_CV",+ "kind": "electrical",+ "unit": "V",+ "min": 2.5,+ "typ": 2.65,+ "max": 2.8,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Lower clamp voltage",+ "symbol": "VCOMP_L",+ "kind": "electrical",+ "unit": "V",+ "min": 1.15,+ "typ": 1.21,+ "max": 1.27,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Comp voltage where min-off time changes",+ "symbol": "VCOMP_MID",+ "kind": "electrical",+ "unit": "V",+ "min": 1.3,+ "typ": 1.39,+ "max": 1.47,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Slope rate of normal operation",+ "symbol": "α",+ "kind": "electrical",+ "unit": "V/µs",+ "min": 0.24,+ "typ": 0.28,+ "max": 0.3,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Minimum on time (CV)",+ "symbol": "Tmin_ON_time",+ "kind": "electrical",+ "unit": "ns",+ "min": 310,+ "typ": 480,+ "max": 620,+ "conditions": "CV",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Minimum on time (CC)",+ "symbol": "Tmin_ON_time",+ "kind": "electrical",+ "unit": "ns",+ "min": 900,+ "typ": 1100,+ "max": 1400,+ "conditions": "CC",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Bias current of ZCD",+ "symbol": "Ibias_ZCD",+ "kind": "electrical",+ "unit": "μA",+ "min": 255,+ "typ": 315,+ "max": 355,+ "conditions": "During turn on",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Brown-out protection threshold",+ "symbol": "Vbrown out",+ "kind": "electrical",+ "unit": "V",+ "min": 0.16,+ "typ": 0.185,+ "max": 0.21,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Brown-out detection time",+ "symbol": "Tbrown out",+ "kind": "electrical",+ "unit": "ms",+ "min": 11,+ "typ": 18.5,+ "max": 33,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Zero-current detect threshold",+ "symbol": "VZCD_T",+ "kind": "electrical",+ "unit": "V",+ "min": 0.265,+ "typ": 0.29,+ "max": 0.32,+ "conditions": "VZCD falling edge",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Zero-current hysteresis for CV",+ "symbol": "VZCD_hys",+ "kind": "electrical",+ "unit": "V",+ "min": 0.26,+ "typ": 0.3,+ "max": 0.34,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Zero-current hysteresis for CC",+ "symbol": "VZCD_hys",+ "kind": "electrical",+ "unit": "V",+ "min": 0.56,+ "typ": 0.6,+ "max": 0.64,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "ZCD blanking time (CC)",+ "symbol": "tLEB_ZCD",+ "kind": "electrical",+ "unit": "μs",+ "min": 1.2,+ "typ": 1.6,+ "max": 2,+ "conditions": "CC, after turn off, Vs_peak > 0.15V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "ZCD blanking time (CC and CV)",+ "symbol": "tLEB_ZCD",+ "kind": "electrical",+ "unit": "μs",+ "min": 0.6,+ "typ": 0.8,+ "max": 1.1,+ "conditions": "CC and CV, after turn off, Vs_peak < 0.15V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Over-voltage blanking time (CC)",+ "symbol": "tLEB_OVP",+ "kind": "electrical",+ "unit": "μs",+ "min": 1.2,+ "typ": 1.6,+ "max": 2,+ "conditions": "CC, after turn off, Vs_peak > 0.15V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Over-voltage blanking time (CC and CV)",+ "symbol": "tLEB_OVP",+ "kind": "electrical",+ "unit": "μs",+ "min": 0.6,+ "typ": 0.8,+ "max": 1.1,+ "conditions": "CC and CV, after turn off, Vs_peak < 0.15V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Over-voltage threshold",+ "symbol": "VZCD_OVP",+ "kind": "electrical",+ "unit": "V",+ "min": 4.7,+ "typ": 4.9,+ "max": 5.2,+ "conditions": "1.6μs delay after turn-off",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Continue drain current",+ "symbol": "ID_D_VCC",+ "kind": "electrical",+ "unit": "mA",+ "min": 9.5,+ "typ": 13.5,+ "max": 18.5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Minimum off time in CC mode",+ "symbol": "Tmin_OFF_CC",+ "kind": "electrical",+ "unit": "µs",+ "min": 4.4,+ "typ": 5,+ "max": 6.2,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum min off time depending on COMP",+ "symbol": "Tmax_OFF_CC",+ "kind": "electrical",+ "unit": "µs",+ "min": 165,+ "typ": 210,+ "max": 270,+ "conditions": "COMP = VCOMP_L",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Start timer period",+ "symbol": "tSTART",+ "kind": "electrical",+ "unit": "µs",+ "min": 150,+ "typ": 175,+ "max": 215,+ "conditions": "ZCD not detected in CC",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CV mode current limit",+ "symbol": "Vcv_limit",+ "kind": "electrical",+ "unit": "V",+ "min": 0.38,+ "typ": 0.45,+ "max": 0.5,+ "conditions": "With S pin blanking 450ns",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CC mode current limit",+ "symbol": "VCC_limit",+ "kind": "electrical",+ "unit": "V",+ "min": 1.4,+ "typ": 1.47,+ "max": 1.55,+ "conditions": "With S pin blanking 450ns",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CV mode current limit foldback",+ "symbol": "Vcv_limit_foldback",+ "kind": "electrical",+ "unit": "V",+ "min": 0.15,+ "typ": 0.2,+ "max": 0.235,+ "conditions": "With S pin blanking 450ns",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Primary over-current protection",+ "symbol": "Vprimary_OCP",+ "kind": "electrical",+ "unit": "V",+ "min": 1.9,+ "typ": 2,+ "max": 2.1,+ "conditions": "With S pin blanking 350ns",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Leading edge blanking time",+ "symbol": "Tblank_S",+ "kind": "electrical",+ "unit": "ns",+ "min": 310,+ "typ": 480,+ "max": 620,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage (VCC)",+ "symbol": "VCC",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 28,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "ZCD",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Low-side MOSFET drain-to-source voltage",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.7,+ "typ": null,+ "max": 28,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "All other pins",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous power dissipation (SOIC-8)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 1.3,+ "conditions": "TA = 25°C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Lead temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage (VCC)",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 6,+ "typ": null,+ "max": 27,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temp. (TJ)",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance SOIC-8 junction-to-ambient",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 96,+ "max": null,+ "conditions": "JESD51-7, 4-layer PCB",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance SOIC-8 junction-to-case",+ "symbol": "θJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 45,+ "max": null,+ "conditions": "JESD51-7, 4-layer PCB",+ "source_page": 3,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "mp4059gs-z"+ ],+ "discovery_pitch": "MP4059GS-Z (Monolithic Power Systems) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "mp4059gs-z", "title": "MP4059GS-Z", "brief": "Monolithic Power Systems LED Drivers, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "mp4059gs-z.kicad_sym", "footprint": "mp4059gs-z.kicad_mod", "model_3d": "mp4059gs-z-hero.glb",- "model_3d_plain": "mp4059gs-z-etched.glb",+ "model_3d_plain": "mp4059gs-z.glb", "model_3d_step": "mp4059gs-z-etched.step", "model_3d_step_plain": "mp4059gs-z.step", "lbr": "mp4059gs-z.lbr"@@ -908,9 +908,10 @@ "viewers/footprint.html", "mp4059gs-z-hero.glb", "mp4059gs-z-hero.overlay.json",- "mp4059gs-z-etched.glb"+ "mp4059gs-z-etched.glb",+ "mp4059gs-z-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Monolithic Power Systems LED Drivers, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }