main
Ray Publish 0.1.0 fdf71d6 9d ago
{
  "slug": "max6751ka29-t",
  "version": "0.1.0",
  "type": "component",
  "description": "Maxim Integrated Monitors & Reset Circuits, SOT-23-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
  "tags": [
    "component",
    "power management ics",
    "max6751ka29+t",
    "factory-2.0.0",
    "extractor-text"
  ],
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "max6751ka29-t.kicad_sym",
    "max6751ka29-t.kicad_mod",
    "max6751ka29-t.glb",
    "max6751ka29-t.step",
    "max6751ka29-t.lbr",
    "docs/hero.png",
    "docs/max6751ka29-t-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "max6751ka29-t-hero.glb",
    "max6751ka29-t-hero.overlay.json",
    "max6751ka29-t-etched.glb"
  ],
  "component": {
    "mpn": "MAX6751KA29+T",
    "manufacturer": "Maxim Integrated",
    "package": "SOT-23-8",
    "pin_count": 8,
    "category": "Power Management ICs",
    "subcategory": "Monitors & Reset Circuits",
    "datasheet": "https://www.analog.com/media/en/technical-documentation/data-sheets/max6746-max6753.pdf",
    "parts": {
      "symbol": "max6751ka29-t.kicad_sym",
      "footprint": "max6751ka29-t.kicad_mod",
      "model_3d": "max6751ka29-t-hero.glb",
      "model_3d_plain": "max6751ka29-t-etched.glb",
      "model_3d_step": "max6751ka29-t-etched.step",
      "model_3d_step_plain": "max6751ka29-t.step",
      "lbr": "max6751ka29-t.lbr"
    },
    "distributor_links": {
      "lcsc": "C2067116",
      "digikey": "MAX6751KA29+TTR-ND",
      "mouser": "700-MAX6751KA29T"
    },
    "distributor_check": {
      "checked_at": "2026-10-31T09:30:12Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": "MAX6751KA29+TTR-ND",
        "status": "found"
      },
      "mouser": {
        "pn": "700-MAX6751KA29T",
        "status": "found"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "RESET IN",
        "type": "input",
        "description": "High-impedance input to the adjustable reset comparator (threshold 1.235V typ); connect to the center point of an external resistor divider to set the monitored voltage threshold."
      },
      {
        "number": "2",
        "name": "SWT",
        "type": "passive",
        "description": "Watchdog timeout input; a capacitor to ground sets tWD = 4.94 x 10^6 x CSWT (seconds, Farads), and connecting SWT to ground disables the watchdog timer."
      },
      {
        "number": "3",
        "name": "SRT",
        "type": "passive",
        "description": "Reset timeout input; a capacitor from SRT to GND sets tRP = 4.94 x 10^6 x CSRT (seconds, Farads)."
      },
      {
        "number": "4",
        "name": "GND",
        "type": "power_in",
        "description": "Ground."
      },
      {
        "number": "5",
        "name": "WDS",
        "type": "input",
        "description": "Watchdog select input; connect to ground for normal mode or to VCC for extended mode (basic timeout multiplied by 128), and a change of state clears the watchdog timer."
      },
      {
        "number": "6",
        "name": "WDI",
        "type": "input",
        "description": "Watchdog input; a falling transition must occur within the selected watchdog timeout period or a reset pulse occurs, it must not be left floating, and a 100k resistor to ground is recommended when the watchdog is unused."
      },
      {
        "number": "7",
        "name": "RESET",
        "type": "output",
        "description": "Open-drain active-low reset output (MAX6751) that asserts when VCC or RESET IN drops below its threshold or on a watchdog fault, and stays low for the reset timeout period after all reset conditions deassert; may be pulled up to 0 to 6V."
      },
      {
        "number": "8",
        "name": "VCC",
        "type": "power_in",
        "description": "Supply voltage input and input for the fixed-threshold VCC monitor; operates from 1.0V to 5.5V (1.2V to 5.5V for TA = -40°C to 0°C)."
      }
    ],
    "provenance": {
      "extractor": "extract_pins 0.3",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins 0.3",
        "primary_model": "claude-sonnet-5-5",
        "primary_mode": "text",
        "consensus_model": "claude-sonnet-5-5",
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "extractor flagged: MAX6751 is the open-drain RESET variant per the Selector Guide; the pin table shows a single shared ; SWT and SRT are capacitor-programming pins; 'passive' type chosen as the closest KiCad class."
        ],
        "pages_sent": 15,
        "cost_usd": 0.0871,
        "at": "2026-10-31T09:30:02"
      },
      "datasheet": {
        "url": "https://www.analog.com/media/en/technical-documentation/data-sheets/max6746-max6753.pdf",
        "pages": 15,
        "sha256": "144a666c7b8478b6",
        "source_tier": "mfr"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 8,
        "described": 8,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "max6751ka29-t.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.8,
          2.9,
          1.2
        ],
        "zmin_mm": -0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "b9dc5b435d49868df7491668d5322debfe5d699dbb41c2ad93a41518ec9b5007",
        "checked": "2026-10-31",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "max6751ka29-t-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.8,
          2.9,
          1.2
        ],
        "zmin_mm": -0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "021fcd108ddaec0b40f2b2ae5a38415ad050be678a8c008c9bad492634f01bd8",
        "checked": "2026-10-31",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  }
}