← Commit history
package.json+541−4@@ -1,6 +1,6 @@ { "slug": "max6635msa",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Maxim Integrated Temperature Sensors, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "max6635msa-hero.glb", "max6635msa-hero.overlay.json",- "max6635msa-etched.glb"+ "max6635msa-etched.glb",+ "max6635msa-etched.step" ], "component": { "mpn": "MAX6635MSA+",@@ -43,7 +44,7 @@ "symbol": "max6635msa.kicad_sym", "footprint": "max6635msa.kicad_mod", "model_3d": "max6635msa-hero.glb",- "model_3d_plain": "max6635msa-etched.glb",+ "model_3d_plain": "max6635msa.glb", "model_3d_step": "max6635msa-etched.step", "model_3d_step_plain": "max6635msa.step", "lbr": "max6635msa.lbr"@@ -188,5 +189,541 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "MAX6635MSA+",+ "brief": "Maxim Integrated Temperature Sensors, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Maxim Integrated",+ "Package": "SOIC-8",+ "Category": "Sensors",+ "Pins": "8"+ },+ "appearance": {+ "contacts": {+ "quote": "plastic packages primarily through the leads. Short, wide copper traces leading to the temperature monitor ensure",+ "page": 12,+ "doc": "ds.pdf",+ "material": "copper"+ },+ "version": 1,+ "datasheet_sha256": "f5bdd44a15b9a26dc676fa6a41048bb263d19d364ec433f158f3455ffd8799f8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "f5bdd44a15b9a26dc676fa6a41048bb263d19d364ec433f158f3455ffd8799f8",+ "rows": [+ {+ "name": "Supply Range",+ "symbol": "VCC",+ "kind": "electrical",+ "unit": "V",+ "min": 3,+ "typ": null,+ "max": 5.5,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Accuracy 0°C to +50°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": -1,+ "typ": 0.4,+ "max": 1,+ "conditions": "0°C ≤ TA ≤ +50°C, VCC = +3.3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Accuracy -20°C to +85°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": -1.5,+ "typ": 0.6,+ "max": 1.5,+ "conditions": "-20°C ≤ TA ≤ +85°C, VCC = +3.3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Accuracy -40°C to +125°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": -2.5,+ "typ": 1,+ "max": 2.5,+ "conditions": "-40°C ≤ TA ≤ 125°C, VCC = +3.3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Accuracy at -55°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": -2.8,+ "typ": 1.5,+ "max": 2.8,+ "conditions": "TA = -55°C, VCC = +3.3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Accuracy at +150°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": null,+ "typ": 2.5,+ "max": null,+ "conditions": "TA = +150°C, VCC = +3.3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power-Supply Rejection Ratio",+ "symbol": "PSRR",+ "kind": "electrical",+ "unit": "°C/V",+ "min": null,+ "typ": 0.2,+ "max": 0.5,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "POR Threshold Hysteresis",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 90,+ "max": null,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Supply Current in Shutdown",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 12,+ "max": 20,+ "conditions": "VCC = +3.0V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Supply Current in Shutdown",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 20,+ "max": 30,+ "conditions": "VCC = +5.5V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Average Operating Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 150,+ "max": null,+ "conditions": "VCC = +3.0V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Average Operating Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 200,+ "max": null,+ "conditions": "VCC = +5.5V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Peak Operating Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 270,+ "max": 350,+ "conditions": "VCC = +3.0V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Peak Operating Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 350,+ "max": 700,+ "conditions": "VCC = +5.5V, SMBus inactive",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Conversion Rate",+ "symbol": "",+ "kind": "electrical",+ "unit": "Hz",+ "min": 1.4,+ "typ": 2,+ "max": 2.4,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Logic Input Low Voltage",+ "symbol": "VIL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.65,+ "conditions": "VCC = +3.0V to +5.5V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Logic Input High Voltage",+ "symbol": "VIH",+ "kind": "electrical",+ "unit": "V",+ "min": 2.2,+ "typ": null,+ "max": null,+ "conditions": "VCC = +3V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Logic Input High Voltage",+ "symbol": "VIH",+ "kind": "electrical",+ "unit": "V",+ "min": 2.4,+ "typ": null,+ "max": null,+ "conditions": "VCC = +5.5V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input Leakage Current",+ "symbol": "II_LEAK",+ "kind": "electrical",+ "unit": "µA",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "VIN = GND or VCC",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output Low Sink Current",+ "symbol": "IOL",+ "kind": "electrical",+ "unit": "mA",+ "min": 6,+ "typ": null,+ "max": null,+ "conditions": "VOL = 0.6V (SMBDATA, ALERT, OVERT)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Output Leakage Current",+ "symbol": "IO_LEAK",+ "kind": "electrical",+ "unit": "µA",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "ALERT, OVERT at VCC",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Input Capacitance",+ "symbol": "CIN",+ "kind": "electrical",+ "unit": "pF",+ "min": null,+ "typ": 5,+ "max": null,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Serial Clock Frequency",+ "symbol": "fSCL",+ "kind": "timing",+ "unit": "kHz",+ "min": 10,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Bus Free Time Between STOP and START Condition",+ "symbol": "tBUF",+ "kind": "timing",+ "unit": "µs",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "START Condition Setup Time",+ "symbol": "",+ "kind": "timing",+ "unit": "µs",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Repeat START Condition Setup Time",+ "symbol": "tSU:STA",+ "kind": "timing",+ "unit": "µs",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "90% to 90%",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "START Condition Hold Time",+ "symbol": "tHD:STA",+ "kind": "timing",+ "unit": "µs",+ "min": 4,+ "typ": null,+ "max": null,+ "conditions": "10% of SMBDATA to 90% of SMBCLK",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "STOP Condition Setup Time",+ "symbol": "tSU:STO",+ "kind": "timing",+ "unit": "µs",+ "min": 4,+ "typ": null,+ "max": null,+ "conditions": "90% of SMBCLK to 10% of SMBDATA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Data Setup Time",+ "symbol": "tSU:DAT",+ "kind": "timing",+ "unit": "ns",+ "min": 250,+ "typ": null,+ "max": null,+ "conditions": "90% of SMBDATA to 10% of SMBCLK",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Data Hold Time",+ "symbol": "tHD:DAT",+ "kind": "timing",+ "unit": "ns",+ "min": 300,+ "typ": null,+ "max": null,+ "conditions": "Note 4",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Receive SCL/SDA Rise Time",+ "symbol": "tR",+ "kind": "timing",+ "unit": "µs",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "SCL/SDA Fall Time",+ "symbol": "tF",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "Note 4",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Clock Low Period",+ "symbol": "tLOW",+ "kind": "timing",+ "unit": "µs",+ "min": 4.7,+ "typ": null,+ "max": null,+ "conditions": "10% to 10%",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Clock High Period",+ "symbol": "tHIGH",+ "kind": "timing",+ "unit": "µs",+ "min": 4,+ "typ": null,+ "max": null,+ "conditions": "90% to 90%",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "SMBus Timeout",+ "symbol": "",+ "kind": "timing",+ "unit": "ms",+ "min": 25,+ "typ": null,+ "max": 48,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage (VCC, SDA, SCL)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "VCC, SDA, SCL",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "SDA, ALERT, OVERT Current",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -1,+ "typ": null,+ "max": 50,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Temperature Range",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Lead Temperature (soldering, 10s)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance Junction to Ambient",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 170,+ "max": null,+ "conditions": "8-pin SO package",+ "source_page": 12,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "max6635msa+"+ ],+ "discovery_pitch": "MAX6635MSA+ (Maxim Integrated) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "max6635msa", "title": "MAX6635MSA+", "brief": "Maxim Integrated Temperature Sensors, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "max6635msa.kicad_sym", "footprint": "max6635msa.kicad_mod", "model_3d": "max6635msa-hero.glb",- "model_3d_plain": "max6635msa-etched.glb",+ "model_3d_plain": "max6635msa.glb", "model_3d_step": "max6635msa-etched.step", "model_3d_step_plain": "max6635msa.step", "lbr": "max6635msa.lbr"@@ -735,9 +735,10 @@ "viewers/footprint.html", "max6635msa-hero.glb", "max6635msa-hero.overlay.json",- "max6635msa-etched.glb"+ "max6635msa-etched.glb",+ "max6635msa-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Maxim Integrated Temperature Sensors, SOIC-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }