component
MAL214066221E3
Public Made by Adomby adom
Vishay Intertech Aluminum Electrolytic Capacitors - Leaded, CP_Radial_D10.0mm_P5.00mm. Polarised capacitor: pin 1 is + by the KiCad polarised-footprint convention, KiCad symbol/footprint/3D.
← Commit history
mal214066221e3: factory component page (tier=lcsc)
2 files changed
+37−222
mal214066221e3-etched.step+1−1@@ -1,7 +1,7 @@ ISO-10303-21; HEADER; FILE_DESCRIPTION(('Open CASCADE Model'),'2;1');-FILE_NAME('Open CASCADE Shape Model','2026-11-07T02:43:37',('Author'),(+FILE_NAME('Open CASCADE Shape Model','2026-11-11T18:51:37',('Author'),( 'Open CASCADE'),'Open CASCADE STEP processor 7.8','Open CASCADE 7.8' ,'Unknown'); FILE_SCHEMA(('AUTOMOTIVE_DESIGN { 1 0 10303 214 1 1 1 1 }'));
page.json+36−221@@ -3,7 +3,7 @@ "type": "component", "slug": "mal214066221e3", "title": "MAL214066221E3",- "brief": "Vishay Intertech Aluminum Electrolytic Capacitors - Leaded, 插件. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "brief": "Vishay Intertech Aluminum Electrolytic Capacitors - Leaded, CP_Radial_D10.0mm_P5.00mm. Polarised capacitor: pin 1 is + by the KiCad polarised-footprint convention, KiCad symbol/footprint/3D.", "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [@@ -105,12 +105,12 @@ "origin": "footprint origin = pad-pattern centre", "seat": "body on z = 0, through-hole leads below", "extents_mm": [- 10,- 10,- 12+ 10.0,+ 10.0,+ 12.0 ],- "zmin_mm": -2,- "centre_offset_mm": 0,+ "zmin_mm": -2.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "7367f35dd5439e325ba3912de65e9200831fdc6698080ffd056cd268649ba41d", "checked": "2026-11-11",@@ -124,12 +124,12 @@ "origin": "footprint origin = pad-pattern centre", "seat": "body on z = 0, through-hole leads below", "extents_mm": [- 10,- 10,- 12+ 10.0,+ 10.0,+ 12.0 ],- "zmin_mm": -2,- "centre_offset_mm": 0,+ "zmin_mm": -2.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "35f0e19bf06123162364bf501e513ad72ee09d30329f31fc634052278f853eff", "checked": "2026-11-11",@@ -154,7 +154,7 @@ ] }, "e": {- "nom_mm": 5,+ "nom_mm": 5.0, "range_mm": [ 4.5, 5.5@@ -191,8 +191,8 @@ "datasheet_sha256": "a81c9710d31a808c5b20d2eb62800356dfb63e4a2838e67b1fb1aedded0e06bb", "rows": [ {- "name": "Tolerance on rated capacitance CR",- "symbol": "",+ "name": "Tolerance on rated capacitance",+ "symbol": "CR", "kind": "tolerance", "unit": "%", "min": -20,@@ -202,18 +202,6 @@ "source_page": 1, "source": "datasheet" },- {- "name": "Max. leakage current after 1 min at UR (IL1)",- "symbol": "IL1",- "kind": "electrical",- "unit": "µA",- "min": null,- "typ": null,- "max": 58,- "conditions": "after 1 min at UR",- "source_page": 3,- "source": "datasheet"- }, { "name": "Max. dissipation factor", "symbol": "tan δ",@@ -251,135 +239,39 @@ "source": "datasheet" }, {- "name": "Endurance test capacitance change",- "symbol": "C/C",- "kind": "tolerance",- "unit": "%",- "min": -15,- "typ": null,- "max": 15,- "conditions": "Tamb = 125 °C; UR applied; 2000 h",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Endurance test dissipation factor limit",- "symbol": "tan δ",- "kind": "electrical",- "unit": "x spec. limit",- "min": null,- "typ": null,- "max": 1.3,- "conditions": "Tamb = 125 °C; UR applied; 2000 h",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Endurance test impedance limit",- "symbol": "Z",- "kind": "electrical",- "unit": "x spec. limit",- "min": null,- "typ": null,- "max": 2,- "conditions": "Tamb = 125 °C; UR applied; 2000 h",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Useful life capacitance change",- "symbol": "C/C",- "kind": "tolerance",- "unit": "%",- "min": -30,- "typ": null,- "max": 30,- "conditions": "Tamb = 125 °C; UR and IR applied; per Table 3 duration",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Useful life dissipation factor limit",- "symbol": "tan δ",- "kind": "electrical",- "unit": "x spec. limit",- "min": null,- "typ": null,- "max": 3,- "conditions": "Tamb = 125 °C; UR and IR applied",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Useful life impedance limit",- "symbol": "Z",- "kind": "electrical",- "unit": "x spec. limit",- "min": null,- "typ": null,- "max": 3,- "conditions": "Tamb = 125 °C; UR and IR applied",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Shelf life capacitance change",- "symbol": "C/C",- "kind": "tolerance",- "unit": "%",- "min": -15,- "typ": null,- "max": 15,- "conditions": "Tamb = 125 °C; no voltage applied; 500 h",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Shelf life dissipation factor limit",- "symbol": "tan δ",- "kind": "electrical",- "unit": "x spec. limit",- "min": null,- "typ": null,- "max": 1.3,- "conditions": "Tamb = 125 °C; no voltage applied; 500 h",- "source_page": 6,- "source": "datasheet"- },- {- "name": "Shelf life impedance limit",- "symbol": "Z",+ "name": "Max. leakage current",+ "symbol": "IL1", "kind": "electrical",- "unit": "x spec. limit",+ "unit": "μA", "min": null, "typ": null,- "max": 2,- "conditions": "Tamb = 125 °C; no voltage applied; 500 h",- "source_page": 6,+ "max": 58,+ "conditions": "1 min at UR",+ "source_page": 3, "source": "datasheet" }, {- "name": "Shelf life leakage current limit",- "symbol": "IL5",+ "name": "Rated RMS ripple current",+ "symbol": "IR", "kind": "electrical",- "unit": "x spec. limit",+ "unit": "mA", "min": null, "typ": null,- "max": 2,- "conditions": "Tamb = 125 °C; no voltage applied; 500 h",- "source_page": 6,+ "max": 750,+ "conditions": "100 kHz, 125 °C",+ "source_page": 3, "source": "datasheet" }, {- "name": "Surge voltage",- "symbol": "Us",- "kind": "absolute_maximum",- "unit": "x UR",+ "name": "Rated voltage",+ "symbol": "UR",+ "kind": "recommended_operating",+ "unit": "V", "min": null, "typ": null,- "max": 1.15,+ "max": 25, "conditions": "",- "source_page": 4,+ "source_page": 3, "source": "datasheet" }, {@@ -406,89 +298,17 @@ "source_page": 1, "source": "datasheet" },- {- "name": "Rated voltage",- "symbol": "UR",- "kind": "electrical",- "unit": "V",- "min": null,- "typ": 25,- "max": null,- "conditions": "",- "source_page": 3,- "source": "datasheet"- }, { "name": "Rated capacitance", "symbol": "CR", "kind": "electrical",- "unit": "µF",+ "unit": "μF", "min": null, "typ": 220, "max": null,- "conditions": "at 100 Hz",- "source_page": 3,- "source": "datasheet"- },- {- "name": "Rated RMS ripple current (IR)",- "symbol": "IR",- "kind": "electrical",- "unit": "mA",- "min": null,- "typ": 750,- "max": null,- "conditions": "100 kHz, 125 °C",+ "conditions": "100 Hz", "source_page": 3, "source": "datasheet"- },- {- "name": "Equivalent series inductance (ESL)",- "symbol": "ESL",- "kind": "electrical",- "unit": "nH",- "min": null,- "typ": 16,- "max": null,- "conditions": "case Ø D = 10 mm",- "source_page": 4,- "source": "datasheet"- },- {- "name": "Endurance test duration at 125 °C",- "symbol": "",- "kind": "electrical",- "unit": "h",- "min": null,- "typ": 2000,- "max": null,- "conditions": "case 10 x 16 mm",- "source_page": 5,- "source": "datasheet"- },- {- "name": "Useful life at 125 °C",- "symbol": "",- "kind": "electrical",- "unit": "h",- "min": null,- "typ": 3000,- "max": null,- "conditions": "case 10 x 16 mm; IR applied",- "source_page": 5,- "source": "datasheet"- },- {- "name": "Shelf life at 0 V, 125 °C",- "symbol": "",- "kind": "electrical",- "unit": "h",- "min": null,- "typ": 500,- "max": null,- "conditions": "Tamb = 125 °C; no voltage applied",- "source_page": 6,- "source": "datasheet" } ] }@@ -529,10 +349,5 @@ "mal214066221e3-hero.glb", "mal214066221e3-hero.overlay.json", "mal214066221e3-etched.glb"- ],- "visibility": {- "public": true- },- "description": "Vishay Intertech Aluminum Electrolytic Capacitors - Leaded, CP_Radial_D10.0mm_P5.00mm. Polarised capacitor: pin 1 is + by the KiCad polarised-footprint convention, KiCad symbol/footprint/3D.",- "org": "adom"-}+ ]+}