main
Ray
Set visibility: public
caace63
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661
{
"schema_version": 1,
"type": "component",
"slug": "ltc2924cgn",
"title": "LTC2924CGN",
"brief": "Analog Devices Monitors & Reset Circuits, SSOP-16-150mil. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"power management ics",
"ltc2924cgn#trpbf",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "LTC2924CGN",
"manufacturer": "Analog Devices",
"package": "SSOP-16-150mil",
"pin_count": 16,
"category": "Power Management ICs",
"subcategory": "Monitors & Reset Circuits",
"datasheet": "https://www.analog.com/media/en/technical-documentation/data-sheets/2924fc.pdf",
"parts": {
"symbol": "ltc2924cgn.kicad_sym",
"footprint": "ltc2924cgn.kicad_mod",
"model_3d": "ltc2924cgn-hero.glb",
"model_3d_plain": "ltc2924cgn.glb",
"model_3d_step": "ltc2924cgn-etched.step",
"model_3d_step_plain": "ltc2924cgn.step",
"lbr": "ltc2924cgn.lbr"
},
"distributor_links": {
"lcsc": "C2657809",
"digikey": "LTC2924CGN#TRPBFTR-ND",
"mouser": "584-LTC2924CGN#TRPBF"
},
"distributor_check": {
"checked_at": "2026-11-13T10:14:13Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "LTC2924CGN#TRPBFTR-ND",
"status": "found"
},
"mouser": {
"pn": "584-LTC2924CGN#TRPBF",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "IN1",
"type": "input",
"description": "Sequenced power supply monitor input connected to a resistive divider; 0.61V (typ) indicates the supply is on during Power On or off during Power Off, and hysteresis current (0.5/RHYS) is sourced out of this pin after the threshold is detected."
},
{
"number": "2",
"name": "IN2",
"type": "input",
"description": "Sequenced power supply monitor input connected to a resistive divider; 0.61V (typ) indicates the supply is on during Power On or off during Power Off, and hysteresis current (0.5/RHYS) is sourced out of this pin after the threshold is detected."
},
{
"number": "3",
"name": "IN3",
"type": "input",
"description": "Sequenced power supply monitor input connected to a resistive divider; 0.61V (typ) indicates the supply is on during Power On or off during Power Off, and hysteresis current (0.5/RHYS) is sourced out of this pin after the threshold is detected."
},
{
"number": "4",
"name": "IN4",
"type": "input",
"description": "Sequenced power supply monitor input connected to a resistive divider; 0.61V (typ) indicates the supply is on during Power On or off during Power Off, and hysteresis current (0.5/RHYS) is sourced out of this pin after the threshold is detected."
},
{
"number": "5",
"name": "OUT1",
"type": "output",
"description": "Sequenced power supply enable; low through <240Ω to GND when disabled, and when enabled driven from the internal charge pump (nominally VCC + 5V) via a 10µA (typ) current source, with output voltage limited to VCC + 4.5V (absolute maximum)."
},
{
"number": "6",
"name": "OUT2",
"type": "output",
"description": "Sequenced power supply enable; low through <240Ω to GND when disabled, and when enabled driven from the internal charge pump (nominally VCC + 5V) via a 10µA (typ) current source, with output voltage limited to VCC + 4.5V (absolute maximum)."
},
{
"number": "7",
"name": "OUT3",
"type": "output",
"description": "Sequenced power supply enable; low through <240Ω to GND when disabled, and when enabled driven from the internal charge pump (nominally VCC + 5V) via a 10µA (typ) current source, with output voltage limited to VCC + 4.5V (absolute maximum)."
},
{
"number": "8",
"name": "OUT4",
"type": "output",
"description": "Sequenced power supply enable; low through <240Ω to GND when disabled, and when enabled driven from the internal charge pump (nominally VCC + 5V) via a 10µA (typ) current source, with output voltage limited to VCC + 4.5V (absolute maximum)."
},
{
"number": "9",
"name": "FAULT",
"type": "bidirectional",
"description": "Open-drain fault pin that must be pulled up with an external 10k resistor; the device pulls it low on a detected fault, and an external pull-down below 0.6V held for at least 1µs causes a simultaneous unsequenced power off."
},
{
"number": "10",
"name": "DONE",
"type": "output",
"description": "Open-drain output that must be pulled to VCC with an external 10k resistor; it pulls low when the Power On sequence completes and floats at the end of the Power Off sequence."
},
{
"number": "11",
"name": "VCC",
"type": "power_in",
"description": "Supply input for all internal circuits with a 3V to 6V supply range, to be bypassed with at least 0.1µF to GND close to the device."
},
{
"number": "12",
"name": "PGT",
"type": "bidirectional",
"description": "Power good timer pin where a capacitor to GND sets a 200ms/µF timeout and a fault is asserted if the pin reaches 1V; it must be connected directly to GND to disable the timer and CPGT/CTMR should be kept between 1 and 100."
},
{
"number": "13",
"name": "GND",
"type": "power_in",
"description": "Ground reference for all internal circuits, to be connected to the ground of the power supplies being sequenced."
},
{
"number": "14",
"name": "TMR",
"type": "bidirectional",
"description": "Timer pin where a capacitor to GND sets a 200ms/µF delay between sequenced supplies, may be left floating for minimum delay, is driven to VCC during an internal fault, and must not have any other circuits connected to it."
},
{
"number": "15",
"name": "HYS/CFG",
"type": "passive",
"description": "Hysteresis current setting pin where a resistor to GND (or to VCC on cascaded devices) programs a 0.5/REXT (typ) hysteresis current, with RHYS between 10kΩ and 1MΩ."
},
{
"number": "16",
"name": "ON",
"type": "input",
"description": "On command input that starts the Power On sequence when above 0.61V (typ) and the Power Off sequence when below 0.61V, with hysteresis current applied while above threshold."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-haiku-5-5",
"primary_mode": "text",
"consensus_model": "claude-sonnet-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: Pin numbers were taken from the GN package top-view layout (pins 1-8 on the left, 9-16 on the right,"
],
"pages_sent": 22,
"cost_usd": 0.104,
"at": "2026-11-13T10:14:00"
},
"datasheet": {
"url": "https://www.analog.com/media/en/technical-documentation/data-sheets/2924fc.pdf",
"pages": 22,
"sha256": "024f313858bb1c22",
"source_tier": "mfr"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 16,
"described": 16,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "ltc2924cgn.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
4.9,
1.85
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "3b55ed1c8dc3eb976cfab8b1e135fd29a17f33ebf575a8a088a30e82c9a5f2ee",
"checked": "2026-11-13",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "ltc2924cgn-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
4.9,
1.85
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "c7e251e166b47b80dd63433c4f60b3d7a2bf1aa43c09fd5223707752b51f4eb4",
"checked": "2026-11-13",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "Analog Devices",
"Package": "SSOP-16-150mil",
"Category": "Power Management ICs",
"Pins": "16"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "024f313858bb1c225647ad795c81fe8b8d688ed4fb10c5e3c1e2b09873f94154",
"rows": [
{
"name": "VCC Input Supply Range",
"symbol": "VCC",
"kind": "electrical",
"unit": "V",
"min": 3,
"typ": null,
"max": 6,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Input Supply Current",
"symbol": "ICC",
"kind": "electrical",
"unit": "mA",
"min": null,
"typ": 1.5,
"max": 3,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, Low to High Threshold",
"symbol": "VON(TH)",
"kind": "electrical",
"unit": "V",
"min": 0.6,
"typ": 0.606,
"max": 0.6121,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, High to Low Threshold",
"symbol": "VOFF(TH)",
"kind": "electrical",
"unit": "V",
"min": 0.6014,
"typ": 0.6074,
"max": 0.6135,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "IN1-IN4 Low to High Threshold",
"symbol": "VON(TH)",
"kind": "electrical",
"unit": "V",
"min": 0.602,
"typ": 0.6081,
"max": 0.6142,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "IN1-IN4 High to Low Threshold",
"symbol": "VOFF(TH)",
"kind": "electrical",
"unit": "V",
"min": 0.6026,
"typ": 0.6087,
"max": 0.6148,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 High Speed Low Fault Threshold",
"symbol": "VFAULT",
"kind": "electrical",
"unit": "V",
"min": 0.33,
"typ": 0.4,
"max": 0.48,
"conditions": "",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 Hysteresis Current Range",
"symbol": "ION(HYS)",
"kind": "electrical",
"unit": "µA",
"min": 0.5,
"typ": null,
"max": 50,
"conditions": "VON ≥ VON(TH) (Note 2)",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 Hysteresis Current Error (0.5µA ≤ ION < 25µA)",
"symbol": "ION(ERROR)",
"kind": "electrical",
"unit": "%",
"min": -22,
"typ": null,
"max": 22,
"conditions": "VON(TH) = 1V; 0.5µA ≤ ION < 25µA",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 Hysteresis Current Error (25µA ≤ ION ≤ 50µA)",
"symbol": "ION(ERROR)",
"kind": "electrical",
"unit": "%",
"min": -10,
"typ": null,
"max": 10,
"conditions": "VON(TH) = 1V; 25µA ≤ ION ≤ 50µA",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 Leakage (Below Threshold)",
"symbol": "ILEAK",
"kind": "electrical",
"unit": "nA",
"min": -100,
"typ": 2,
"max": 100,
"conditions": "VON(TH) = 0.5V",
"source_page": 3,
"source": "datasheet"
},
{
"name": "ON, IN1-IN4 Minimum Hysteresis Voltage",
"symbol": "VON(HYS)",
"kind": "electrical",
"unit": "mV",
"min": 4,
"typ": null,
"max": null,
"conditions": "IHYS • RIN (Note 6)",
"source_page": 3,
"source": "datasheet"
},
{
"name": "OUT1-OUT4 On Current",
"symbol": "IOUT(EN)",
"kind": "electrical",
"unit": "µA",
"min": 8.6,
"typ": 10,
"max": 11.2,
"conditions": "OUTn On, VOUT = (VCC + 4V)",
"source_page": 3,
"source": "datasheet"
},
{
"name": "OUT1-OUT4 Off Resistance to GND",
"symbol": "ROUT(OFF)",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 240,
"conditions": "OUTn Off, IOUT = 2mA",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Timer Pin Output Current",
"symbol": "ITMR",
"kind": "electrical",
"unit": "µA",
"min": 4,
"typ": 5,
"max": 6,
"conditions": "Timer On, VTMR ≤ 0.9V",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Timer High Voltage Threshold",
"symbol": "VTH(HI)",
"kind": "electrical",
"unit": "V",
"min": 0.93,
"typ": 1,
"max": 1.07,
"conditions": "VCC = 5V",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Power Good Timer Pin Output Current",
"symbol": "IPGT",
"kind": "electrical",
"unit": "µA",
"min": 4,
"typ": 5,
"max": 6,
"conditions": "Power Good Timer On, VPGT ≤ 0.9V",
"source_page": 3,
"source": "datasheet"
},
{
"name": "Power Good Timer Fault Detected Voltage Threshold",
"symbol": "VPGT",
"kind": "electrical",
"unit": "V",
"min": 0.93,
"typ": 1,
"max": 1.07,
"conditions": "VCC = 5V",
"source_page": 3,
"source": "datasheet"
},
{
"name": "DONE Pin Pull-Down Resistance to GND",
"symbol": "RD(LO)",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 100,
"conditions": "DONE = Low, I = 2mA",
"source_page": 4,
"source": "datasheet"
},
{
"name": "DONE Pin Off Leakage Current",
"symbol": "ID(HI)",
"kind": "electrical",
"unit": "µA",
"min": null,
"typ": null,
"max": 15,
"conditions": "DONE = High",
"source_page": 4,
"source": "datasheet"
},
{
"name": "FAULT Pin Pull-Down Resistance to GND",
"symbol": "RFAULT(LO)",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 400,
"conditions": "FAULT Being Pulled Low Internally, I = 2mA",
"source_page": 4,
"source": "datasheet"
},
{
"name": "FAULT Pin Off Leakage Current",
"symbol": "IFAULT(HI)",
"kind": "electrical",
"unit": "µA",
"min": null,
"typ": null,
"max": 2,
"conditions": "FAULT High",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Voltage Above Which an Externally Generated FAULT Condition Will Not be Detected",
"symbol": "VFAULT(HI)",
"kind": "electrical",
"unit": "V",
"min": 1.6,
"typ": null,
"max": null,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Voltage Below Which an Externally Generated FAULT Condition Will be Detected",
"symbol": "VFAULT(LO)",
"kind": "electrical",
"unit": "V",
"min": null,
"typ": null,
"max": 0.6,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "External Pull-Up Resistance on FAULT",
"symbol": "RF(EXT)",
"kind": "recommended_operating",
"unit": "kΩ",
"min": null,
"typ": 10,
"max": null,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Externally Commanded FAULT Below VFAULT(LO) to OUT1-OUT4 Pull-Down On Delay",
"symbol": "tFAULT",
"kind": "timing",
"unit": "µs",
"min": null,
"typ": null,
"max": 1,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Externally Commanded FAULT Minimum Time Below VFAULT(LO)",
"symbol": "tFAULT(MIN)",
"kind": "timing",
"unit": "µs",
"min": 1,
"typ": null,
"max": null,
"conditions": "Determined by design, not production tested (Note 4)",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Supply Voltage (VCC)",
"symbol": "VCC",
"kind": "absolute_maximum",
"unit": "V",
"min": -0.3,
"typ": null,
"max": 6.5,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Operating Temperature Range, LTC2924C",
"symbol": "TA",
"kind": "recommended_operating",
"unit": "°C",
"min": 0,
"typ": null,
"max": 70,
"conditions": "LTC2924CGN (commercial grade)",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Storage Temperature Range",
"symbol": "TSTG",
"kind": "absolute_maximum",
"unit": "°C",
"min": -65,
"typ": null,
"max": 150,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Maximum Junction Temperature",
"symbol": "TJMAX",
"kind": "thermal",
"unit": "°C",
"min": null,
"typ": null,
"max": 125,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Junction-to-Ambient Thermal Resistance",
"symbol": "θJA",
"kind": "thermal",
"unit": "°C/W",
"min": null,
"typ": 130,
"max": null,
"conditions": "GN package",
"source_page": 2,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"ltc2924cgn#trpbf"
],
"discovery_pitch": "LTC2924CGN#TRPBF (Analog Devices) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"ltc2924cgn.kicad_sym",
"ltc2924cgn.kicad_mod",
"ltc2924cgn.glb",
"ltc2924cgn.step",
"ltc2924cgn.lbr",
"docs/hero.png",
"docs/ltc2924cgn-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"ltc2924cgn-hero.glb",
"ltc2924cgn-hero.overlay.json"
],
"visibility": {