← Commit history
package.json+699−4@@ -1,6 +1,6 @@ { "slug": "lt8390eufd-pbf",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Analog Devices DC-DC Converters, QFN-28-EP(4x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "lt8390eufd-pbf-hero.glb", "lt8390eufd-pbf-hero.overlay.json",- "lt8390eufd-pbf-etched.glb"+ "lt8390eufd-pbf-etched.glb",+ "lt8390eufd-pbf-etched.step" ], "component": { "mpn": "LT8390EUFD#PBF",@@ -43,7 +44,7 @@ "symbol": "lt8390eufd-pbf.kicad_sym", "footprint": "lt8390eufd-pbf.kicad_mod", "model_3d": "lt8390eufd-pbf-hero.glb",- "model_3d_plain": "lt8390eufd-pbf-etched.glb",+ "model_3d_plain": "lt8390eufd-pbf.glb", "model_3d_step": "lt8390eufd-pbf-etched.step", "model_3d_step_plain": "lt8390eufd-pbf.step", "lbr": "lt8390eufd-pbf.lbr"@@ -351,5 +352,699 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "LT8390EUFD#PBF",+ "brief": "Analog Devices DC-DC Converters, QFN-28-EP(4x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Analog Devices",+ "Package": "QFN-28-EP(4x5)",+ "Category": "Power Management",+ "Pins": "29"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "bedb46ecab867bbe77f1fea37f990ec0a77eb8284de4f6c839e48b7b5f69d678",+ "rows": [+ {+ "name": "VIN Operating Voltage Range",+ "symbol": "VIN",+ "kind": "electrical",+ "unit": "V",+ "min": 4,+ "typ": null,+ "max": 60,+ "conditions": "l (full operating temperature range)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "VOUT Voltage Range",+ "symbol": "VOUT",+ "kind": "electrical",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 60,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "INTVCC Regulation Voltage",+ "symbol": "VINTVCC",+ "kind": "electrical",+ "unit": "V",+ "min": 4.85,+ "typ": 5,+ "max": 5.15,+ "conditions": "IINTVCC = 20mA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "INTVCC Current Limit",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": 80,+ "typ": 110,+ "max": 160,+ "conditions": "VINTVCC = 4.5V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "INTVCC Undervoltage Lockout Threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 3.44,+ "typ": 3.54,+ "max": 3.64,+ "conditions": "Falling",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "VREF Regulation Voltage",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.97,+ "typ": 2,+ "max": 2.03,+ "conditions": "l; IVREF = 100µA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "VREF Current Limit",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": 2,+ "typ": 2.5,+ "max": 3.2,+ "conditions": "VREF = 1.8V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "VREF Undervoltage Lockout Threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 1.78,+ "typ": 1.84,+ "max": 1.9,+ "conditions": "Falling",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "EN/UVLO Shutdown Threshold",+ "symbol": "EN/UVLO",+ "kind": "electrical",+ "unit": "V",+ "min": 0.3,+ "typ": 0.6,+ "max": 1,+ "conditions": "l",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "EN/UVLO Enable Threshold Falling",+ "symbol": "EN/UVLO",+ "kind": "electrical",+ "unit": "V",+ "min": 1.196,+ "typ": 1.22,+ "max": 1.244,+ "conditions": "l",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "EN/UVLO Hysteresis Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": -0.1,+ "typ": 0,+ "max": 0.1,+ "conditions": "VEN/UVLO = 0.3V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "EN/UVLO Hysteresis Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 2.2,+ "typ": 2.5,+ "max": 2.9,+ "conditions": "VEN/UVLO = 1.1V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "CTRL Input Bias Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "nA",+ "min": 0,+ "typ": 20,+ "max": 50,+ "conditions": "VCTRL = 0.75V, current out of pin",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "CTRL Latch-Off Threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": 285,+ "typ": 300,+ "max": 315,+ "conditions": "l; Falling",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "LOADEN Threshold",+ "symbol": "LOADEN",+ "kind": "electrical",+ "unit": "V",+ "min": 1.3,+ "typ": 1.4,+ "max": 1.5,+ "conditions": "l; Rising",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "LOADTG On Voltage",+ "symbol": "V(VOUT-LOADTG)",+ "kind": "electrical",+ "unit": "V",+ "min": 4.6,+ "typ": 5,+ "max": 5.6,+ "conditions": "VOUT = 12V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "LOADTG Off Voltage",+ "symbol": "V(VOUT-LOADTG)",+ "kind": "electrical",+ "unit": "V",+ "min": -0.1,+ "typ": 0,+ "max": 0.1,+ "conditions": "VOUT = 12V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Full Scale Current Regulation",+ "symbol": "V(ISP-ISN)",+ "kind": "electrical",+ "unit": "mV",+ "min": 97,+ "typ": 100,+ "max": 103,+ "conditions": "l; VCTRL = 2V, VISP = 12V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "1/10th Current Regulation",+ "symbol": "V(ISP-ISN)",+ "kind": "electrical",+ "unit": "mV",+ "min": 8,+ "typ": 10,+ "max": 12,+ "conditions": "l; VCTRL = 0.35V, VISP = 12V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ISMON Monitor Output",+ "symbol": "VISMON",+ "kind": "electrical",+ "unit": "V",+ "min": 1.2,+ "typ": 1.25,+ "max": 1.3,+ "conditions": "l; V(ISP-ISN) = 100mV, VISP = 12V/0V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ISMON Monitor Output",+ "symbol": "VISMON",+ "kind": "electrical",+ "unit": "V",+ "min": 0.3,+ "typ": 0.35,+ "max": 0.4,+ "conditions": "l; V(ISP-ISN) = 10mV, VISP = 12V/0V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ISMON Monitor Output",+ "symbol": "VISMON",+ "kind": "electrical",+ "unit": "V",+ "min": 0.2,+ "typ": 0.25,+ "max": 0.3,+ "conditions": "l; V(ISP-ISN) = 0mV, VISP = 12V/0V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ISP/ISN Input Common Mode Range",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 60,+ "conditions": "l",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "FB Regulation Voltage",+ "symbol": "VFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.985,+ "typ": 1,+ "max": 1.015,+ "conditions": "l; VC = 1.2V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum Current Sense Threshold (Buck)",+ "symbol": "V(LSP-LSN)",+ "kind": "electrical",+ "unit": "mV",+ "min": 35,+ "typ": 50,+ "max": 65,+ "conditions": "l; Buck, VFB = 0.8V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Current Sense Threshold (Boost)",+ "symbol": "V(LSP-LSN)",+ "kind": "electrical",+ "unit": "mV",+ "min": 40,+ "typ": 50,+ "max": 60,+ "conditions": "l; Boost, VFB = 0.8V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB Overvoltage Threshold",+ "symbol": "VFB",+ "kind": "electrical",+ "unit": "V",+ "min": 1.08,+ "typ": 1.1,+ "max": 1.12,+ "conditions": "l; Rising",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB Overvoltage Hysteresis",+ "symbol": "VFB",+ "kind": "electrical",+ "unit": "mV",+ "min": 35,+ "typ": 50,+ "max": 65,+ "conditions": "l",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB Short Threshold",+ "symbol": "VFB",+ "kind": "electrical",+ "unit": "V",+ "min": 0.24,+ "typ": 0.25,+ "max": 0.26,+ "conditions": "l; Falling",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "PGOOD Upper Threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": 8,+ "typ": 10,+ "max": 12,+ "conditions": "l; Offset from VFB, rising",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "PGOOD Lower Threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -12,+ "typ": -10,+ "max": -8,+ "conditions": "l; Offset from VFB, falling",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SS Pull-Up Current",+ "symbol": "ISS",+ "kind": "electrical",+ "unit": "µA",+ "min": 10.5,+ "typ": 12.5,+ "max": 14.5,+ "conditions": "VFB = 0.4V, VSS = 0V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SS Pull-Down Current",+ "symbol": "ISS",+ "kind": "electrical",+ "unit": "µA",+ "min": 1.05,+ "typ": 1.25,+ "max": 1.45,+ "conditions": "VFB = 0.1V, VSS = 2V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Switching Frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 190,+ "typ": 200,+ "max": 210,+ "conditions": "l; VSYNC/SPRD = 0V, RT = 226kΩ",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Switching Frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 380,+ "typ": 400,+ "max": 420,+ "conditions": "l; VSYNC/SPRD = 0V, RT = 100kΩ",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Switching Frequency",+ "symbol": "fSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 570,+ "typ": 600,+ "max": 630,+ "conditions": "l; VSYNC/SPRD = 0V, RT = 59.0kΩ",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SYNC Frequency",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 150,+ "typ": null,+ "max": 650,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SYNC/SPRD Input Bias Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": -0.1,+ "typ": 0,+ "max": 0.1,+ "conditions": "VSYNC/SPRD = 5V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Highest Spread Spectrum Above Oscillator Frequency",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": 12.5,+ "typ": 14.5,+ "max": 16.5,+ "conditions": "VSYNC/SPRD = 5V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Lowest Spread Spectrum Below Oscillator Frequency",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": -17.7,+ "typ": -15.7,+ "max": -13.7,+ "conditions": "VSYNC/SPRD = 5V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Buck-Boost to Boost Region Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 0.73,+ "typ": 0.75,+ "max": 0.77,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Boost to Buck-Boost Region Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 0.83,+ "typ": 0.85,+ "max": 0.87,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Buck to Buck-Boost Region Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 1.16,+ "typ": 1.18,+ "max": 1.2,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Buck-Boost to Buck Region Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 1.31,+ "typ": 1.33,+ "max": 1.35,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Peak-Buck to Peak-Boost Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 0.96,+ "typ": 0.98,+ "max": 1,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Peak-Boost to Peak-Buck Transition",+ "symbol": "VIN/VOUT",+ "kind": "electrical",+ "unit": "VIN/VOUT",+ "min": 1,+ "typ": 1.02,+ "max": 1.04,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: VIN, EN/UVLO, VOUT, ISP, ISN",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: ISP-ISN",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: SW1, SW2, LSP, LSN",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -6,+ "typ": null,+ "max": 60,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: INTVCC, (BST1-SW1), (BST2-SW2)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: (BST1-LSP), (BST1-LSN)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Absolute maximum voltage: FB, LOADEN, SYNC/SPRD, CTRL, PGOOD",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature Range, LT8390E",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "LT8390E grade",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance, junction-to-ambient (UFD QFN package)",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 43,+ "max": null,+ "conditions": "UFD 28-lead 4mm × 5mm QFN package",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance, junction-to-case (UFD QFN package)",+ "symbol": "θJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 3.4,+ "max": null,+ "conditions": "UFD 28-lead 4mm × 5mm QFN package",+ "source_page": 2,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "lt8390eufd#pbf"+ ],+ "discovery_pitch": "LT8390EUFD#PBF (Analog Devices) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "lt8390eufd-pbf", "title": "LT8390EUFD#PBF", "brief": "Analog Devices DC-DC Converters, QFN-28-EP(4x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "lt8390eufd-pbf.kicad_sym", "footprint": "lt8390eufd-pbf.kicad_mod", "model_3d": "lt8390eufd-pbf-hero.glb",- "model_3d_plain": "lt8390eufd-pbf-etched.glb",+ "model_3d_plain": "lt8390eufd-pbf.glb", "model_3d_step": "lt8390eufd-pbf-etched.step", "model_3d_step_plain": "lt8390eufd-pbf.step", "lbr": "lt8390eufd-pbf.lbr"@@ -1056,9 +1056,10 @@ "viewers/footprint.html", "lt8390eufd-pbf-hero.glb", "lt8390eufd-pbf-hero.overlay.json",- "lt8390eufd-pbf-etched.glb"+ "lt8390eufd-pbf-etched.glb",+ "lt8390eufd-pbf-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Analog Devices DC-DC Converters, QFN-28-EP(4x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }