← Commit history
lt1009idr: specified limits as data (metadata.characteristics, 19 rows from the datasheet)
2 files changed
+261
README.md+26@@ -26,6 +26,32 @@ LT1009IDR from Texas Instruments, in a SOIC-8. Pinout and pin descriptions extra | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reference voltage (25°C, D package) | VZ | 2.49 | 2.5 | 2.51 | V | IZ = 1 mA, TA = 25°C, D/PW package | 4 |+| Reference voltage (full range, D package) | VZ | 2.475 | | 2.525 | V | IZ = 1 mA, TA = –40°C to 85°C, D/PW package | 4 |+| Forward voltage | VF | | 0.4 | 1 | V | IF = 2 mA, TA = 25°C | 4 |+| Adjustment range | | | | 125 | mV | IZ = 1 mA, VADJ = GND to VZ, TA = 25°C | 4 |+| Adjustment range (limited span) | | | | 45 | mV | IZ = 1 mA, VADJ = 0.6 V to VZ – 0.6 V, TA = 25°C | 4 |+| Change in reference voltage with temperature (full range, D package) | ΔVZ(temp) | | | 15 | mV | Full range (–40°C to 85°C for LT1009I) | 4 |+| Average temperature coefficient of reference voltage (0°C to 70°C) | αVZ | | 15 | 25 | ppm/°C | IZ = 1 mA, VADJ = open, TA = 0°C to 70°C | 4 |+| Average temperature coefficient of reference voltage (–40°C to 85°C) | αVZ | | 20 | 35 | ppm/°C | IZ = 1 mA, VADJ = open, TA = –40°C to 85°C | 4 |+| Change in reference voltage with current (25°C) | ΔVZ | | 2.6 | 6 | mV | IZ = 400 µA to 10 mA, TA = 25°C | 4 |+| Change in reference voltage with current (full range) | ΔVZ | | | 10 | mV | IZ = 400 µA to 10 mA, full range | 4 |+| Long-term change in reference voltage | ΔVZ/Δt | | 20 | | ppm/khr | IZ = 1 mA, TA = 25°C | 4 |+| Reference impedance (25°C) | ZZ | | 0.3 | 1 | Ω | IZ = 1 mA, TA = 25°C | 4 |+| Reference impedance (full range) | ZZ | | | 1.4 | Ω | IZ = 1 mA, full range | 4 |+| Reverse current | IR | | | 20 | mA | | 3 |+| Forward current | IF | | | 10 | mA | | 3 |+| Package thermal impedance, D package | θJA | | 97 | | °C/W | D package, per JESD 51-7 | 3 |+| Operating virtual junction temperature | TJ | | | 150 | °C | | 3 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 3 |+| Operating free-air temperature range (LT1009I) | TA | -40 | | 85 | °C | LT1009I | 3 |+ ## CAD (KiCad official) - Symbol: `LT1009IDR`
page.json+235@@ -179,6 +179,241 @@ "Package": "SOIC-8", "Category": "Power Management (PMIC)", "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "0de77fb68649fe68",+ "rows": [+ {+ "name": "Reference voltage (25°C, D package)",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "V",+ "min": 2.49,+ "typ": 2.5,+ "max": 2.51,+ "conditions": "IZ = 1 mA, TA = 25°C, D/PW package",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Reference voltage (full range, D package)",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "V",+ "min": 2.475,+ "typ": null,+ "max": 2.525,+ "conditions": "IZ = 1 mA, TA = –40°C to 85°C, D/PW package",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Forward voltage",+ "symbol": "VF",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.4,+ "max": 1,+ "conditions": "IF = 2 mA, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Adjustment range",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "IZ = 1 mA, VADJ = GND to VZ, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Adjustment range (limited span)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 45,+ "conditions": "IZ = 1 mA, VADJ = 0.6 V to VZ – 0.6 V, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Change in reference voltage with temperature (full range, D package)",+ "symbol": "ΔVZ(temp)",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "Full range (–40°C to 85°C for LT1009I)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of reference voltage (0°C to 70°C)",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": null,+ "typ": 15,+ "max": 25,+ "conditions": "IZ = 1 mA, VADJ = open, TA = 0°C to 70°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of reference voltage (–40°C to 85°C)",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": null,+ "typ": 20,+ "max": 35,+ "conditions": "IZ = 1 mA, VADJ = open, TA = –40°C to 85°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Change in reference voltage with current (25°C)",+ "symbol": "ΔVZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 2.6,+ "max": 6,+ "conditions": "IZ = 400 µA to 10 mA, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Change in reference voltage with current (full range)",+ "symbol": "ΔVZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "IZ = 400 µA to 10 mA, full range",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Long-term change in reference voltage",+ "symbol": "ΔVZ/Δt",+ "kind": "electrical",+ "unit": "ppm/khr",+ "min": null,+ "typ": 20,+ "max": null,+ "conditions": "IZ = 1 mA, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Reference impedance (25°C)",+ "symbol": "ZZ",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.3,+ "max": 1,+ "conditions": "IZ = 1 mA, TA = 25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Reference impedance (full range)",+ "symbol": "ZZ",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 1.4,+ "conditions": "IZ = 1 mA, full range",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Reverse current",+ "symbol": "IR",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Forward current",+ "symbol": "IF",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Package thermal impedance, D package",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 97,+ "max": null,+ "conditions": "D package, per JESD 51-7",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating virtual junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating free-air temperature range (LT1009I)",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "LT1009I",+ "source_page": 3,+ "source": "datasheet"+ }+ ] } }, "variants": [],