← Commit history

lt1009idr: specified limits as data (metadata.characteristics, 19 rows from the datasheet)

Ray ·349d682ed8 · ·parent d70be6d
2 files changed +261
README.md+26
@@ -26,6 +26,32 @@ LT1009IDR from Texas Instruments, in a SOIC-8. Pinout and pin descriptions extra | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reference voltage (25°C, D package) | VZ | 2.49 | 2.5 | 2.51 | V | IZ = 1 mA, TA = 25°C, D/PW package | 4 |+| Reference voltage (full range, D package) | VZ | 2.475 |  | 2.525 | V | IZ = 1 mA, TA = –40°C to 85°C, D/PW package | 4 |+| Forward voltage | VF |  | 0.4 | 1 | V | IF = 2 mA, TA = 25°C | 4 |+| Adjustment range |  |  |  | 125 | mV | IZ = 1 mA, VADJ = GND to VZ, TA = 25°C | 4 |+| Adjustment range (limited span) |  |  |  | 45 | mV | IZ = 1 mA, VADJ = 0.6 V to VZ – 0.6 V, TA = 25°C | 4 |+| Change in reference voltage with temperature (full range, D package) | ΔVZ(temp) |  |  | 15 | mV | Full range (–40°C to 85°C for LT1009I) | 4 |+| Average temperature coefficient of reference voltage (0°C to 70°C) | αVZ |  | 15 | 25 | ppm/°C | IZ = 1 mA, VADJ = open, TA = 0°C to 70°C | 4 |+| Average temperature coefficient of reference voltage (–40°C to 85°C) | αVZ |  | 20 | 35 | ppm/°C | IZ = 1 mA, VADJ = open, TA = –40°C to 85°C | 4 |+| Change in reference voltage with current (25°C) | ΔVZ |  | 2.6 | 6 | mV | IZ = 400 µA to 10 mA, TA = 25°C | 4 |+| Change in reference voltage with current (full range) | ΔVZ |  |  | 10 | mV | IZ = 400 µA to 10 mA, full range | 4 |+| Long-term change in reference voltage | ΔVZ/Δt |  | 20 |  | ppm/khr | IZ = 1 mA, TA = 25°C | 4 |+| Reference impedance (25°C) | ZZ |  | 0.3 | 1 | Ω | IZ = 1 mA, TA = 25°C | 4 |+| Reference impedance (full range) | ZZ |  |  | 1.4 | Ω | IZ = 1 mA, full range | 4 |+| Reverse current | IR |  |  | 20 | mA |  | 3 |+| Forward current | IF |  |  | 10 | mA |  | 3 |+| Package thermal impedance, D package | θJA |  | 97 |  | °C/W | D package, per JESD 51-7 | 3 |+| Operating virtual junction temperature | TJ |  |  | 150 | °C |  | 3 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 3 |+| Operating free-air temperature range (LT1009I) | TA | -40 |  | 85 | °C | LT1009I | 3 |+ ## CAD (KiCad official)  - Symbol: `LT1009IDR`
page.json+235
@@ -179,6 +179,241 @@       "Package": "SOIC-8",       "Category": "Power Management (PMIC)",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "0de77fb68649fe68",+      "rows": [+        {+          "name": "Reference voltage (25°C, D package)",+          "symbol": "VZ",+          "kind": "electrical",+          "unit": "V",+          "min": 2.49,+          "typ": 2.5,+          "max": 2.51,+          "conditions": "IZ = 1 mA, TA = 25°C, D/PW package",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage (full range, D package)",+          "symbol": "VZ",+          "kind": "electrical",+          "unit": "V",+          "min": 2.475,+          "typ": null,+          "max": 2.525,+          "conditions": "IZ = 1 mA, TA = –40°C to 85°C, D/PW package",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Forward voltage",+          "symbol": "VF",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.4,+          "max": 1,+          "conditions": "IF = 2 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Adjustment range",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "IZ = 1 mA, VADJ = GND to VZ, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Adjustment range (limited span)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 45,+          "conditions": "IZ = 1 mA, VADJ = 0.6 V to VZ – 0.6 V, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with temperature (full range, D package)",+          "symbol": "ΔVZ(temp)",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "Full range (–40°C to 85°C for LT1009I)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Average temperature coefficient of reference voltage (0°C to 70°C)",+          "symbol": "αVZ",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 15,+          "max": 25,+          "conditions": "IZ = 1 mA, VADJ = open, TA = 0°C to 70°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Average temperature coefficient of reference voltage (–40°C to 85°C)",+          "symbol": "αVZ",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 20,+          "max": 35,+          "conditions": "IZ = 1 mA, VADJ = open, TA = –40°C to 85°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current (25°C)",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 2.6,+          "max": 6,+          "conditions": "IZ = 400 µA to 10 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current (full range)",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "IZ = 400 µA to 10 mA, full range",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Long-term change in reference voltage",+          "symbol": "ΔVZ/Δt",+          "kind": "electrical",+          "unit": "ppm/khr",+          "min": null,+          "typ": 20,+          "max": null,+          "conditions": "IZ = 1 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference impedance (25°C)",+          "symbol": "ZZ",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.3,+          "max": 1,+          "conditions": "IZ = 1 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference impedance (full range)",+          "symbol": "ZZ",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 1.4,+          "conditions": "IZ = 1 mA, full range",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse current",+          "symbol": "IR",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Forward current",+          "symbol": "IF",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Package thermal impedance, D package",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 97,+          "max": null,+          "conditions": "D package, per JESD 51-7",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature range (LT1009I)",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "LT1009I",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],