main
Ray lr432btlt1g: specified limits as data (metadata.characteristics, 16 rows from the datasheet) b39a64d
{
  "slug": "lr432btlt1g",
  "version": "0.1.0",
  "type": "component",
  "description": "LRC Supervisor and Reset ICs, SOT-23. Datasheet-verified pinout, KiCad symbol/footprint/3D.",
  "tags": [
    "component",
    "pmic",
    "lr432btlt1g"
  ],
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "lr432btlt1g.kicad_sym",
    "lr432btlt1g.kicad_mod",
    "lr432btlt1g.glb",
    "lr432btlt1g.step",
    "lr432btlt1g.lbr",
    "docs/hero.png",
    "docs/lr432btlt1g-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "lr432btlt1g-etched.step"
  ],
  "visibility": {
    "public": true
  },
  "author": {
    "name": "Ray"
  },
  "component": {
    "mpn": "LR432BTLT1G",
    "manufacturer": "LRC",
    "package": "SOT-23",
    "pin_count": 3,
    "category": "Supervisor and Reset ICs",
    "parts": {
      "symbol": "lr432btlt1g.kicad_sym",
      "footprint": "lr432btlt1g.kicad_mod",
      "model_3d": "lr432btlt1g-etched.glb",
      "model_3d_plain": "lr432btlt1g.glb",
      "model_3d_step": "lr432btlt1g-etched.step",
      "model_3d_step_plain": "lr432btlt1g.step",
      "lbr": "lr432btlt1g.lbr"
    },
    "pins": [
      {
        "number": "1",
        "name": "REF",
        "type": "input",
        "description": "Reference input. High-impedance feedback node compared internally against the 1.240 V bandgap reference; typical input current 0.15 µA (max 0.4 µA) at IKA=10 mA. In an adjustable configuration this pin is driven by the R1/R2 divider between cathode and anode, setting VKA = VREF·(1 + R1/R2) + IREF·R1."
      },
      {
        "number": "2",
        "name": "K",
        "type": "power_in",
        "description": "Cathode. Regulated shunt terminal that sinks the control current when VREF reaches the internal 1.240 V threshold. Absolute maximum cathode voltage VKA = 20 V; continuous cathode current IK = 100 mA; minimum cathode current for regulation IKA(MIN) ≈ 55 µA (80 µA max); off-state leakage 0.04 µA typ at VKA = 18 V."
      },
      {
        "number": "3",
        "name": "A",
        "type": "power_in",
        "description": "Anode. Ground/return terminal for the shunt-regulator current path; the internal reference and the R1/R2 divider are referenced to this pin."
      }
    ],
    "provenance": {
      "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction"
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "distributor_links": {
      "lcsc": "C411185",
      "digikey": false,
      "mouser": false
    },
    "distributor_check": {
      "checked_at": "2026-10-05T19:06:38Z",
      "source": "Component Ocean /api/assign-pns + lcsc_map",
      "digikey": {
        "pn": null,
        "status": "no match"
      },
      "mouser": {
        "pn": null,
        "status": "no match"
      }
    },
    "models_3d": [
      {
        "file": "lr432btlt1g.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.5,
          3,
          1.2
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "dd5d1711204e1d8d26cd11490923bd84340820baa69538c385a4300ec2539bc0",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "lr432btlt1g-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2.5,
          3,
          1.2
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "d4416fce69e02db35c6fa24a5b1164f8d136d5abe997f95163f6db74463cfe19",
        "checked": "2026-10-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": null,
      "rows": [
        {
          "name": "Reference voltage (0.5% grade)",
          "symbol": "VREF",
          "kind": "electrical",
          "unit": "V",
          "min": 1.234,
          "typ": 1.24,
          "max": 1.246,
          "conditions": "VKA=VREF, IKA=10mA",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Reference voltage tolerance",
          "symbol": "",
          "kind": "tolerance",
          "unit": "%",
          "min": -0.5,
          "typ": null,
          "max": 0.5,
          "conditions": "",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Deviation of reference voltage",
          "symbol": "",
          "kind": "electrical",
          "unit": "mV",
          "min": null,
          "typ": 2,
          "max": 10,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Deviation of reference voltage over-temperature",
          "symbol": "",
          "kind": "electrical",
          "unit": "mV",
          "min": null,
          "typ": 3,
          "max": 15,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Ratio of change in VREF to change in cathode voltage",
          "symbol": "VREF/VKA",
          "kind": "voltage_coefficient",
          "unit": "mV/V",
          "min": null,
          "typ": -0.5,
          "max": -1.5,
          "conditions": "VKA: VREF to 16V, IKA=10mA, 0 to 70°C / -20 to 125°C / -40 to 125°C",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Reference input current",
          "symbol": "IREF",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 0.15,
          "max": 0.4,
          "conditions": "IKA=10mA, R1=10K¡, R2=Ğ (as printed)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Deviation of reference current over full temperature range",
          "symbol": "IREF",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 0.1,
          "max": 0.4,
          "conditions": "IKA=10mA, R1=10K¡, R2=Ğ (as printed); TA=-20 to 85°C",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Minimum cathode current for regulation",
          "symbol": "IKA(MIN)",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 55,
          "max": 80,
          "conditions": "VKA=VREF",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Off-state cathode current",
          "symbol": "IKA(OFF)",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 0.04,
          "max": 0.5,
          "conditions": "VREF=0, VKA=18V",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Off-state cathode current",
          "symbol": "IKA(OFF)",
          "kind": "electrical",
          "unit": "µA",
          "min": null,
          "typ": 0.01,
          "max": 0.05,
          "conditions": "VKA=6V, VREF=0",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Dynamic impedance",
          "symbol": "ZKA",
          "kind": "electrical",
          "unit": "Ω",
          "min": null,
          "typ": 0.05,
          "max": 0.15,
          "conditions": "VKA=VREF, IKA=1 to 100mA, f≤1.0kHz (glyph as extracted: fİ1.0kHz)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Cathode voltage",
          "symbol": "VKA",
          "kind": "absolute_maximum",
          "unit": "V",
          "min": null,
          "typ": null,
          "max": 20,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Continuous cathode current range",
          "symbol": "IK",
          "kind": "absolute_maximum",
          "unit": "mA",
          "min": null,
          "typ": null,
          "max": 100,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Reference current range",
          "symbol": "IREF",
          "kind": "absolute_maximum",
          "unit": "mA",
          "min": null,
          "typ": null,
          "max": 10,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Operating ambient temperature",
          "symbol": "Topr",
          "kind": "absolute_maximum",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 125,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Operating junction temperature range",
          "symbol": "Tj",
          "kind": "absolute_maximum",
          "unit": "°C",
          "min": null,
          "typ": null,
          "max": 150,
          "conditions": "",
          "source_page": 2,
          "source": "datasheet"
        }
      ]
    }
  }
}