lm5143qrwgrq1: specified limits as data (metadata.characteristics, 52 rows from the datasheet)

Ray ·484b34691c · ·parent bcb4a25
2 files changed +690
README.md+59
@@ -59,6 +59,65 @@ LM5143QRWGRQ1 from Texas Instruments, in a VQFN-40-EP(6x6). Pinout and pin descr | Category | Power Management (PMIC) | | Pins | 41 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| VCC regulation voltage | VVCC-REG | 4.7 | 5 | 5.3 | V | VVIN = 12 V, IVCC = 100 mA, VVCCX = 0 V | 9 |+| VCC UVLO rising threshold | VVCC-UVLO | 3.2 | 3.3 | 3.4 | V | VVCC rising | 9 |+| VDDA regulation voltage | VVDDA-REG | 4.75 | 5 | 5.25 | V |  | 9 |+| VDDA UVLO rising threshold | VVDDA-UVLO | 3.1 | 3.2 | 3.3 | V | VVCC rising, VVCCX = 0 V | 9 |+| VCCX(ON) rising threshold | VVCCX-ON | 4.1 | 4.3 | 4.4 | V |  | 9 |+| Current limit threshold 1 (CS1 to VOUT1) | VCS1 | 66 | 73 | 80 | mV | Measured from CS1 to VOUT1 | 9 |+| Current limit threshold 2 (CS2 to VOUT2) | VCS2 | 66 | 73 | 80 | mV | Measured from CS2 to VOUT2 | 9 |+| CS amplifier gain | GCS | 11.4 | 12 | 12.6 | V/V |  | 9 |+| PG1 UV trip level | PG1UV | 90 | 92 | 94 | % | Falling with respect to the regulation voltage | 9 |+| PG2 UV trip level | PG2UV | 90 | 92 | 94 | % | Falling with respect to the regulation voltage | 9 |+| PG1 OV trip level | PG1OV | 108 | 110 | 112 | % | Rising with respect to the regulation voltage | 9 |+| PG2 OV trip level | PG2OV | 108 | 110 | 112 | % | Rising with respect to the regulation voltage | 9 |+| 3.3 V output voltage setpoint | VOUT33 | 3.267 | 3.3 | 3.33 | V | VFB = 0 V, VIN = 3.5 V to 65 V | 10 |+| 5 V output voltage setpoint | VOUT50 | 4.95 | 5 | 5.05 | V | VFB = 5 V, VIN = 5.5 V to 65 V | 10 |+| Regulated feedback voltage | VFB-REG | 0.594 | 0.6 | 0.606 | V | TJ = –40°C to 125°C | 10 |+| External SYNC frequency range, % of nominal set by RRT | FSYNCIN | -20 |  | 20 | % | VIN = 8 V to 18 V, % of the nominal frequency set by RRT | 11 |+| Switching frequency 1 | FSW1 | 200 | 220 | 242 | kHz | RRT = 100 kΩ | 12 |+| Soft-start current | ISS | 16 | 21 | 28 | µA | VMODE = 0 V | 12 |+| VIN to PGND (absolute maximum) |  | -0.3 |  | 70 | V |  | 7 |+| SW1, SW2 to PGND (absolute maximum) |  | -0.3 |  | 70 | V |  | 7 |+| SW1, SW2 to PGND (20-ns transient) |  | -5 |  |  | V | 20-ns transient | 7 |+| HB1 to SW1, HB2 to SW2 (absolute maximum) |  | -0.3 |  | 6.5 | V |  | 7 |+| HB1 to SW1, HB2 to SW2 (20-ns transient) |  | -5 |  |  | V | 20-ns transient | 7 |+| HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (max VHB + 0.3 V, not numeric) |  | -0.3 |  |  | V |  | 7 |+| HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (20-ns transient) |  | -5 |  |  | V | 20-ns transient | 7 |+| LO1, LOL1, LO2, LOL2 to PGND (max VVCC + 0.3 V, not numeric) |  | -0.3 |  |  | V |  | 7 |+| LO1, LOL1, LO2, LOL2 to PGND (20-ns transient, max VVCC + 0.3 V) |  | -1.5 |  |  | V | 20-ns transient | 7 |+| SS1, SS2, COMP1, COMP2, RES, RT, MODE, DITH to AGND (max VVDDA + 0.3 V, not numeric) |  | -0.3 |  |  | V |  | 7 |+| EN1, EN2 to PGND (absolute maximum) |  | -0.3 |  | 70 | V |  | 7 |+| VCC, VCCX, VDDA, PG1, PG2, DEMB, FB1, FB2 to AGND (absolute maximum) |  | -0.3 |  | 6.5 | V |  | 7 |+| VOUT1, VOUT2, CS1, CS2 (absolute maximum) |  | -0.3 |  | 60 | V |  | 7 |+| VOUT1 to CS1, VOUT2 to CS2 (absolute maximum) |  | -0.3 |  | 0.3 | V |  | 7 |+| PGND to AGND (absolute maximum) |  | -0.3 |  | 0.3 | V |  | 7 |+| Operating junction temperature, TJ (absolute maximum) | TJ | -40 |  | 150 | °C |  | 7 |+| Storage temperature (absolute maximum) | Tstg | -40 |  | 150 | °C |  | 7 |+| VIN to PGND (recommended operating) |  | -0.3 |  | 65 | V |  | 8 |+| SW1, SW2 to PGND (recommended operating) |  | -0.3 |  | 65 | V |  | 8 |+| HB1 to SW1, HB2 to SW2 (recommended operating) |  | -0.3 | 5 | 5.25 | V |  | 8 |+| HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (recommended operating, max VHB + 0.3 V, not numeric) |  | -0.3 |  |  | V |  | 8 |+| LO1, LOL1, LO2, LOL2 to PGND (recommended operating) |  | -0.3 | 5 | 5.25 | V |  | 8 |+| FB1, FB2, SS1, SS2, COMP1, COMP2, RES, DEMB, RT, MODE, DITH to AGND (recommended operating) |  | -0.3 |  | 5.25 | V |  | 8 |+| EN1, EN2 to PGND (recommended operating) |  | -0.3 |  | 65 | V |  | 8 |+| VCC, VCCX, VDDA to PGND (recommended operating) |  | -0.3 | 5 | 5.25 | V |  | 8 |+| VOUT1, VOUT2, CS1, CS2 to PGND (recommended operating) |  | -0.3 |  | 55 | V |  | 8 |+| PGND to AGND (recommended operating) |  | -0.3 |  | 0.3 | V |  | 8 |+| Operating junction temperature (recommended operating) | TJ | -40 |  | 150 | °C |  | 8 |+| Junction-to-ambient thermal resistance | RΘJA |  | 34.8 |  | °C/W |  | 8 |+| Junction-to-case (top) thermal resistance | RΘJC(top) |  | 22.8 |  | °C/W |  | 8 |+| Junction-to-board thermal resistance | RΘJB |  | 9.5 |  | °C/W |  | 8 |+| Junction-to-case (bottom) thermal resistance | RΘJC(bot) |  | 1.3 |  | °C/W |  | 8 |+| Junction-to-board characterization parameter | ΨJB |  | 9.4 |  | °C/W |  | 8 |+| Junction-to-top characterization parameter | ΨJT |  | 0.3 |  | °C/W |  | 8 |+ ## CAD (KiCad official)  - Symbol: `LM5143QRWGRQ1`
page.json+631
@@ -380,6 +380,637 @@       "Package": "VQFN-40-EP(6x6)",       "Category": "Power Management (PMIC)",       "Pins": "41"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "7f505f2c1dac109f",+      "rows": [+        {+          "name": "VCC regulation voltage",+          "symbol": "VVCC-REG",+          "kind": "electrical",+          "unit": "V",+          "min": 4.7,+          "typ": 5,+          "max": 5.3,+          "conditions": "VVIN = 12 V, IVCC = 100 mA, VVCCX = 0 V",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VCC UVLO rising threshold",+          "symbol": "VVCC-UVLO",+          "kind": "electrical",+          "unit": "V",+          "min": 3.2,+          "typ": 3.3,+          "max": 3.4,+          "conditions": "VVCC rising",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VDDA regulation voltage",+          "symbol": "VVDDA-REG",+          "kind": "electrical",+          "unit": "V",+          "min": 4.75,+          "typ": 5,+          "max": 5.25,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VDDA UVLO rising threshold",+          "symbol": "VVDDA-UVLO",+          "kind": "electrical",+          "unit": "V",+          "min": 3.1,+          "typ": 3.2,+          "max": 3.3,+          "conditions": "VVCC rising, VVCCX = 0 V",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VCCX(ON) rising threshold",+          "symbol": "VVCCX-ON",+          "kind": "electrical",+          "unit": "V",+          "min": 4.1,+          "typ": 4.3,+          "max": 4.4,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold 1 (CS1 to VOUT1)",+          "symbol": "VCS1",+          "kind": "electrical",+          "unit": "mV",+          "min": 66,+          "typ": 73,+          "max": 80,+          "conditions": "Measured from CS1 to VOUT1",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold 2 (CS2 to VOUT2)",+          "symbol": "VCS2",+          "kind": "electrical",+          "unit": "mV",+          "min": 66,+          "typ": 73,+          "max": 80,+          "conditions": "Measured from CS2 to VOUT2",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "CS amplifier gain",+          "symbol": "GCS",+          "kind": "electrical",+          "unit": "V/V",+          "min": 11.4,+          "typ": 12,+          "max": 12.6,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "PG1 UV trip level",+          "symbol": "PG1UV",+          "kind": "electrical",+          "unit": "%",+          "min": 90,+          "typ": 92,+          "max": 94,+          "conditions": "Falling with respect to the regulation voltage",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "PG2 UV trip level",+          "symbol": "PG2UV",+          "kind": "electrical",+          "unit": "%",+          "min": 90,+          "typ": 92,+          "max": 94,+          "conditions": "Falling with respect to the regulation voltage",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "PG1 OV trip level",+          "symbol": "PG1OV",+          "kind": "electrical",+          "unit": "%",+          "min": 108,+          "typ": 110,+          "max": 112,+          "conditions": "Rising with respect to the regulation voltage",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "PG2 OV trip level",+          "symbol": "PG2OV",+          "kind": "electrical",+          "unit": "%",+          "min": 108,+          "typ": 110,+          "max": 112,+          "conditions": "Rising with respect to the regulation voltage",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "3.3 V output voltage setpoint",+          "symbol": "VOUT33",+          "kind": "electrical",+          "unit": "V",+          "min": 3.267,+          "typ": 3.3,+          "max": 3.33,+          "conditions": "VFB = 0 V, VIN = 3.5 V to 65 V",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "5 V output voltage setpoint",+          "symbol": "VOUT50",+          "kind": "electrical",+          "unit": "V",+          "min": 4.95,+          "typ": 5,+          "max": 5.05,+          "conditions": "VFB = 5 V, VIN = 5.5 V to 65 V",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Regulated feedback voltage",+          "symbol": "VFB-REG",+          "kind": "electrical",+          "unit": "V",+          "min": 0.594,+          "typ": 0.6,+          "max": 0.606,+          "conditions": "TJ = –40°C to 125°C",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "External SYNC frequency range, % of nominal set by RRT",+          "symbol": "FSYNCIN",+          "kind": "tolerance",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "VIN = 8 V to 18 V, % of the nominal frequency set by RRT",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency 1",+          "symbol": "FSW1",+          "kind": "electrical",+          "unit": "kHz",+          "min": 200,+          "typ": 220,+          "max": 242,+          "conditions": "RRT = 100 kΩ",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Soft-start current",+          "symbol": "ISS",+          "kind": "electrical",+          "unit": "µA",+          "min": 16,+          "typ": 21,+          "max": 28,+          "conditions": "VMODE = 0 V",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "VIN to PGND (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 70,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "SW1, SW2 to PGND (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 70,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "SW1, SW2 to PGND (20-ns transient)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": null,+          "conditions": "20-ns transient",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "HB1 to SW1, HB2 to SW2 (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "HB1 to SW1, HB2 to SW2 (20-ns transient)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": null,+          "conditions": "20-ns transient",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (max VHB + 0.3 V, not numeric)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (20-ns transient)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": null,+          "conditions": "20-ns transient",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "LO1, LOL1, LO2, LOL2 to PGND (max VVCC + 0.3 V, not numeric)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "LO1, LOL1, LO2, LOL2 to PGND (20-ns transient, max VVCC + 0.3 V)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -1.5,+          "typ": null,+          "max": null,+          "conditions": "20-ns transient",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "SS1, SS2, COMP1, COMP2, RES, RT, MODE, DITH to AGND (max VVDDA + 0.3 V, not numeric)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "EN1, EN2 to PGND (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 70,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "VCC, VCCX, VDDA, PG1, PG2, DEMB, FB1, FB2 to AGND (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6.5,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "VOUT1, VOUT2, CS1, CS2 (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 60,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "VOUT1 to CS1, VOUT2 to CS2 (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "PGND to AGND (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature, TJ (absolute maximum)",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature (absolute maximum)",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "VIN to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 65,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "SW1, SW2 to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 65,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "HB1 to SW1, HB2 to SW2 (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": 5,+          "max": 5.25,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "HO1 to SW1, HOL1 to SW1, HO2 to SW2, HOL2 to SW2 (recommended operating, max VHB + 0.3 V, not numeric)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "LO1, LOL1, LO2, LOL2 to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": 5,+          "max": 5.25,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "FB1, FB2, SS1, SS2, COMP1, COMP2, RES, DEMB, RT, MODE, DITH to AGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 5.25,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "EN1, EN2 to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 65,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "VCC, VCCX, VDDA to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": 5,+          "max": 5.25,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "VOUT1, VOUT2, CS1, CS2 to PGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 55,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "PGND to AGND (recommended operating)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature (recommended operating)",+          "symbol": "TJ",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance",+          "symbol": "RΘJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 34.8,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (top) thermal resistance",+          "symbol": "RΘJC(top)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 22.8,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board thermal resistance",+          "symbol": "RΘJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 9.5,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (bottom) thermal resistance",+          "symbol": "RΘJC(bot)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 1.3,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board characterization parameter",+          "symbol": "ΨJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 9.4,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-top characterization parameter",+          "symbol": "ΨJT",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 0.3,+          "max": null,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],