component
KNSMD012
Public Made by Adomby adom
KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
main
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314
{
"schema_version": 1,
"type": "component",
"slug": "knsmd012",
"title": "KNSMD012",
"brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"knsmd012",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "KNSMD012",
"manufacturer": "KUU",
"package": "1206",
"pin_count": 2,
"category": "Circuit Protection",
"subcategory": "Resettable Fuses",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/34427ac466649f87539d84cb87d883b6.pdf",
"parts": {
"symbol": "knsmd012.kicad_sym",
"footprint": "knsmd012.kicad_mod",
"model_3d": "knsmd012-hero.glb",
"model_3d_plain": "knsmd012-etched.glb",
"model_3d_step": "knsmd012-etched.step",
"model_3d_step_plain": "knsmd012.step",
"lbr": "knsmd012.lbr"
},
"distributor_links": {
"lcsc": "C42441127"
},
"distributor_check": {
"checked_at": "2026-10-17T14:22:17Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": null,
"status": "quota"
},
"mouser": {
"pn": null,
"status": "quota"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "One terminal of the non-polarised PTC resettable fuse, interchangeable with the other terminal; rated Vmax 60 V, Imax 10 A, hold current 0.12 A and trip current 0.29 A at 25°C."
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Second terminal of the non-polarised PTC resettable fuse, interchangeable with the other terminal; rated Vmax 60 V, Imax 10 A, hold current 0.12 A and trip current 0.29 A at 25°C."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-sonnet-5-5",
"primary_mode": "text+vision",
"consensus_model": "claude-opus-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: The datasheet shows two end terminals and two pads but prints no pin numbers or names. Pins 1 and 2 ",
"vision extraction: provenance cannot be text-verified; needs consensus"
],
"pages_sent": 1,
"cost_usd": 0.0777,
"at": "2026-10-17T14:20:04"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/34427ac466649f87539d84cb87d883b6.pdf",
"pages": 1,
"sha256": "cf42e4c710fa1324",
"source_tier": "lcsc"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "knsmd012.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
3.2,
1.6,
0.55
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "5e6dcbe286696143d35a8ea37d91eef4b54ff3d1bd7c2c2b4dedda83d3f8e203",
"checked": "2026-10-17",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "knsmd012-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
3.2,
1.6,
0.55
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "bb260b0e4a7c990688bd69f13ea45b78c2871677cfd8059ddec85b321bd7b3d8",
"checked": "2026-10-17",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "KUU",
"Package": "1206",
"Category": "Circuit Protection",
"Pins": "2"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "cf42e4c710fa13243f34b2a6dbcba80c8144429f7ec1cb51a998b484a1ab7c16",
"rows": [
{
"name": "Minimum resistance prior to trip",
"symbol": "R min",
"kind": "electrical",
"unit": "Ω",
"min": 1.35,
"typ": null,
"max": null,
"conditions": "Minimum resistance of device prior to trip at 25℃",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum resistance one hour post reflow",
"symbol": "R1 max",
"kind": "electrical",
"unit": "Ω",
"min": null,
"typ": null,
"max": 8.5,
"conditions": "Measured one hour post reflow at 25℃",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Holding current",
"symbol": "IH",
"kind": "electrical",
"unit": "A",
"min": null,
"typ": null,
"max": 0.12,
"conditions": "Maximum current at which device will not trip, 25℃ still air",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Tripping current",
"symbol": "IT",
"kind": "electrical",
"unit": "A",
"min": 0.29,
"typ": null,
"max": null,
"conditions": "Minimum current at which device will trip, 25℃ still air",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum voltage device can withstand",
"symbol": "Vmax",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 60,
"conditions": "Without damage at rated current",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum fault current device can withstand",
"symbol": "I max",
"kind": "absolute_maximum",
"unit": "A",
"min": null,
"typ": null,
"max": 10,
"conditions": "Without damage at rated voltage",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Maximum time to trip",
"symbol": "Ttrip",
"kind": "timing",
"unit": "s",
"min": null,
"typ": null,
"max": 0.2,
"conditions": "At assigned current 1.00 A",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Rated working power",
"symbol": "Pd",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.4,
"max": null,
"conditions": "Rated working power",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Average ramp-up rate (reflow)",
"symbol": "",
"kind": "timing",
"unit": "℃/second",
"min": null,
"typ": null,
"max": 3,
"conditions": "Average ramp-up rate, reflow profile",
"source_page": 1,
"source": "datasheet"
},
{
"name": "Ramp-down rate (reflow)",
"symbol": "",
"kind": "timing",
"unit": "℃/second",
"min": null,
"typ": null,
"max": 6,
"conditions": "Ramp-down rate, reflow profile",
"source_page": 1,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"knsmd012"
],
"discovery_pitch": "KNSMD012 (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray",
"email": "[email protected]"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"knsmd012.kicad_sym",
"knsmd012.kicad_mod",
"knsmd012.glb",
"knsmd012.step",
"knsmd012.lbr",
"docs/hero.png",
"docs/knsmd012-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"knsmd012-hero.glb",
"knsmd012-hero.overlay.json",
"knsmd012-etched.glb"
],
"visibility": {
"public": true
}
}