main
History Download
Ray Publish 0.1.0 04a98e1 17d ago

K1210L200

KUU · Resettable Fuses · 1210

K1210L200 from KUU, in a 1210. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive First terminal of the two-terminal PPTC resettable fuse, rated IH 2.00 A hold and IT 4.00 A trip at 25℃, Vmax 8 V, Imax 40 A.
2 2 passive Second terminal of the two-terminal PPTC resettable fuse, interchangeable with the first (non-polarized), rated IH 2.00 A hold and IT 4.00 A trip at 25℃, Vmax 8 V, Imax 40 A.

Key specifications

Parameter Value
Manufacturer KUU
Package 1210
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Holding current IH 2 A Maximum current at which device will not trip, 25℃ still air 1
Tripping current IT 4 A Minimum current at which device will trip, 25℃ still air 1
Minimum resistance prior to trip R min 0.02 Ω 25℃ 1
Maximum resistance one hour post reflow R1max 0.09 Ω Measured one hour post reflow at 25℃ 1
Maximum voltage withstand Vmax 8 V Without damage at rated current 1
Maximum fault current withstand Imax 40 A Without damage at rated voltage 1
Maximum time to trip Ttrip 1 s At 8.00 A 1
Hold current derating IH 3.2 A Maximum ambient operating temperature -40℃ 1
Hold current derating IH 2.8 A Maximum ambient operating temperature -20℃ 1
Hold current derating IH 2.4 A Maximum ambient operating temperature 0℃ 1
Hold current derating IH 2 A Maximum ambient operating temperature 25℃ 1
Hold current derating IH 1.8 A Maximum ambient operating temperature 40℃ 1
Hold current derating IH 1.6 A Maximum ambient operating temperature 50℃ 1
Hold current derating IH 1.4 A Maximum ambient operating temperature 60℃ 1
Hold current derating IH 1.2 A Maximum ambient operating temperature 70℃ 1
Hold current derating IH 1 A Maximum ambient operating temperature 85℃ 1
Trip current derating IT 6.4 A Maximum ambient operating temperature -40℃ 1
Trip current derating IT 5.6 A Maximum ambient operating temperature -20℃ 1
Trip current derating IT 4.8 A Maximum ambient operating temperature 0℃ 1
Trip current derating IT 4 A Maximum ambient operating temperature 25℃ 1
Trip current derating IT 3.6 A Maximum ambient operating temperature 40℃ 1
Trip current derating IT 3.2 A Maximum ambient operating temperature 50℃ 1
Trip current derating IT 2.8 A Maximum ambient operating temperature 60℃ 1
Trip current derating IT 2.4 A Maximum ambient operating temperature 70℃ 1
Trip current derating IT 2 A Maximum ambient operating temperature 85℃ 1
Rated working power Pd 0.7 W Rated working power (typ) 1

CAD (KiCad official)

  • Symbol: K1210L200
  • Footprint: Fuse:Fuse_1210_3225Metric
  • 3D model: 1210 (KiCad packages3D, STEP)
  • 3D model files: k1210l200-etched.step / k1210l200-etched.glb carry the MPN laser-etched on the die in a toggleable Adom.LaserEtch group (Fusion-ready); k1210l200.step / k1210l200.glb are the bare package body.

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: KUU datasheet (1 pp, sha256 b510de6f0dddc1fd, retrieved 2026-10-18, tier: lcsc)
  • Extractor: parts-factory 2.0.0 / extract_pins 0.3, primary claude-sonnet-5-5 (text+vision), consensus claude-opus-5-5 (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF