← Commit history
page.json+16−13@@ -188,11 +188,11 @@ "seat": "z = 0", "extents_mm": [ 6.4,- 5.0,+ 5, 1.1 ],- "zmin_mm": -0.0,- "centre_offset_mm": 0.0,+ "zmin_mm": 0,+ "centre_offset_mm": 0, "footprint_binding": "identity", "sha256": "6ad5e98224d02a427d9a6b929a28dbc158b9925fba5adec12db05079f1016948", "checked": "2026-11-02",@@ -207,11 +207,11 @@ "seat": "z = 0", "extents_mm": [ 6.4,- 5.0,+ 5, 1.1 ],- "zmin_mm": -0.0,- "centre_offset_mm": 0.0,+ "zmin_mm": 0,+ "centre_offset_mm": 0, "footprint_binding": "identity", "sha256": "300e55c342b3be9fcd3d29947f7e3fdd9c81f9d3870fbda22e80db5dfe88c18b", "checked": "2026-11-02",@@ -524,7 +524,7 @@ "symbol": "VDD3", "kind": "recommended_operating", "unit": "V",- "min": 3.0,+ "min": 3, "typ": 3.3, "max": 3.6, "conditions": "",@@ -537,7 +537,7 @@ "kind": "electrical", "unit": "V", "min": 2.85,- "typ": 3.0,+ "typ": 3, "max": 3.1, "conditions": "Internally regulated. Connect a CVA = 100nF capacitor from VDDA to GND.", "source_page": 9,@@ -645,7 +645,7 @@ "kind": "recommended_operating", "unit": "V", "min": 4.5,- "typ": 5.0,+ "typ": 5, "max": 5.5, "conditions": "", "source_page": 9,@@ -657,7 +657,7 @@ "kind": "electrical", "unit": "V", "min": 3.9,- "typ": 4.0,+ "typ": 4, "max": 4.1, "conditions": "Internally regulated. Connect a CVA = 100nF capacitor from VDDA to GND.", "source_page": 9,@@ -716,7 +716,7 @@ "symbol": "V5UVF", "kind": "electrical", "unit": "V",- "min": 4.0,+ "min": 4, "typ": null, "max": 4.6, "conditions": "An under-voltage alarm is cleared if VDD rises above these limits.",@@ -906,5 +906,8 @@ "ips2200bi1r-hero.glb", "ips2200bi1r-hero.overlay.json", "ips2200bi1r-etched.glb"- ]-}+ ],+ "visibility": {+ "public": true+ }+}