← Commit history

Set visibility: public

Ray ·5fd968d35d · ·parent 0991acf
1 file changed +11−8
page.json+11−8
@@ -32,37 +32,37 @@         "number": "1",         "name": "-IN",         "type": "input",-        "description": "Negative (inverting) differential input to the instrumentation amplifier. Input common-mode range includes V- and is protected to \u00b140 V."+        "description": "Negative (inverting) differential input to the instrumentation amplifier. Input common-mode range includes V- and is protected to ±40 V."       },       {         "number": "2",         "name": "RG",         "type": "passive",-        "description": "Gain-setting pin. Connect an external resistor R_G between pin 2 and pin 3 to set the gain per G = 1 + 49.4 k\u03a9 / R_G. Leave open for G = 1."+        "description": "Gain-setting pin. Connect an external resistor R_G between pin 2 and pin 3 to set the gain per G = 1 + 49.4 kΩ / R_G. Leave open for G = 1."       },       {         "number": "3",         "name": "RG",         "type": "passive",-        "description": "Gain-setting pin. Connect an external resistor R_G between pin 2 and pin 3 to set the gain per G = 1 + 49.4 k\u03a9 / R_G. Leave open for G = 1."+        "description": "Gain-setting pin. Connect an external resistor R_G between pin 2 and pin 3 to set the gain per G = 1 + 49.4 kΩ / R_G. Leave open for G = 1."       },       {         "number": "4",         "name": "+IN",         "type": "input",-        "description": "Positive (noninverting) differential input to the instrumentation amplifier. Input common-mode range includes V- and is protected to \u00b140 V."+        "description": "Positive (noninverting) differential input to the instrumentation amplifier. Input common-mode range includes V- and is protected to ±40 V."       },       {         "number": "5",         "name": "-VS",         "type": "power_in",-        "description": "Negative supply rail. Connect to GND for single-supply operation (V+ = 3 V to 36 V) or to a negative rail for dual-supply operation (\u00b11.5 V to \u00b118 V). Bypass with 0.1 \u00b5F to ground."+        "description": "Negative supply rail. Connect to GND for single-supply operation (V+ = 3 V to 36 V) or to a negative rail for dual-supply operation (±1.5 V to ±18 V). Bypass with 0.1 µF to ground."       },       {         "number": "6",         "name": "REF",         "type": "input",-        "description": "Reference input that sets the output zero level (V_O = G \u00d7 (V_IN+ \u2212 V_IN\u2212) + V_REF). Must be driven by a low-impedance source; range \u221220 V to +20 V relative to ground."+        "description": "Reference input that sets the output zero level (V_O = G × (V_IN+ − V_IN−) + V_REF). Must be driven by a low-impedance source; range −20 V to +20 V relative to ground."       },       {         "number": "7",@@ -74,7 +74,7 @@         "number": "8",         "name": "+VS",         "type": "power_in",-        "description": "Positive supply rail. 3 V to 36 V single-supply or +1.5 V to +18 V dual-supply. Bypass with 0.1 \u00b5F to ground close to the pin."+        "description": "Positive supply rail. 3 V to 36 V single-supply or +1.5 V to +18 V dual-supply. Bypass with 0.1 µF to ground close to the pin."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/ina826aidr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file