ina199b2dckr: specified limits as data (metadata.characteristics, 36 rows from the datasheet)

Ray ·5f7ef38ba6 · ·parent ccba8db
2 files changed +484
README.md+43
@@ -31,6 +31,49 @@ INA199B2DCKR from Texas Instruments, in a SOT-363-6. Pinout and pin descriptions - `INA199B2DCKRRSWR` - `INA199B2DCKRRSWT` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Gain error (Version A and B) |  | -1.5 | 0.03 | 1.5 | % | Version A and B, VSENSE = –5 mV to 5 mV, TA = –40°C to 125°C | 7 |+| Gain error vs temperature |  |  | 3 | 10 | ppm/°C | TA = –40°C to 125°C | 7 |+| Common-mode input range | VCM | -0.1 |  | 26 | V | Version B and C, TA = –40°C to 125°C | 7 |+| Common-mode rejection | CMR | 100 | 120 |  | dB | VIN+ = 0 V to 26 V, VSENSE = 0 mV, TA = –40°C to 125°C | 7 |+| Offset voltage, RTI | VOS | -150 | 5 | 150 | μV | VSENSE = 0 mV | 7 |+| VOS vs temperature | dVOS/dT |  | 0.1 | 0.5 | μV/°C | TA = –40°C to 125°C | 7 |+| Maximum capacitive load | CLOAD |  |  | 1 | nF | No sustained oscillation | 7 |+| Swing to V+ power-supply rail |  |  | 0.05 | 0.2 | V | RL = 10 kΩ to GND, TA = –40°C to 125°C; printed as (V+) – x V | 7 |+| Swing to GND |  |  | 0.005 | 0.05 | V | RL = 10 kΩ to GND, TA = –40°C to 125°C; printed as (VGND) + x V | 7 |+| Operating voltage range | VS | 2.7 |  | 26 | V | TA = –40°C to 125°C | 7 |+| Operating voltage range | VS | 2.5 |  | 26 | V | –20°C to 85°C | 7 |+| Quiescent current | IQ |  | 65 | 100 | μA | VSENSE = 0 mV | 7 |+| Quiescent current over temperature | IQ |  |  | 115 | μA | TA = –40°C to 125°C | 7 |+| Specified temperature range |  | -40 |  | 125 | °C |  | 7 |+| Operating temperature range (electrical table) |  | -40 |  | 125 | °C |  | 7 |+| Supply voltage |  |  |  | 26 | V |  | 5 |+| Differential analog input (VIN+) – (VIN–) | VIN+, VIN– | -26 |  | 26 | V |  | 5 |+| Common-mode analog input, INA199Bx and INA199Cx | VIN+, VIN– | -0.1 |  | 26 | V | Referenced to GND (GND – 0.1 V to 26 V) | 5 |+| REF input voltage | VREF | -0.3 |  | 0.3 | V | Min referenced to GND (GND – 0.3 V); max referenced to V+ ((V+) + 0.3 V) | 5 |+| Output voltage | VOUT | -0.3 |  | 0.3 | V | Min referenced to GND (GND – 0.3 V); max referenced to V+ ((V+) + 0.3 V) | 5 |+| Input current into all pins | IIN |  |  | 5 | mA |  | 5 |+| Operating temperature | TA | -40 |  | 125 | °C |  | 5 |+| Junction temperature | TJ |  |  | 150 | °C |  | 5 |+| Storage temperature | Tstg | -65 |  | 150 | °C |  | 5 |+| Electrostatic discharge, human-body model (INA199Bx, INA199Cx in DCK and RSW) | V(ESD) | -3500 |  | 3500 | V | HBM per ANSI/ESDA/JEDEC JS-001 | 5 |+| Electrostatic discharge, charged-device model (INA199Bx, INA199Cx in DCK and RSW) | V(ESD) | -1000 |  | 1000 | V | CDM per JEDEC JESD22-C101 | 5 |+| Common-mode input voltage | VCM |  | 12 |  | V |  | 6 |+| Operating supply voltage (applied to V+) | VS |  | 5 |  | V |  | 6 |+| Operating free-air temperature | TA | -40 |  | 125 | °C |  | 6 |+| Junction-to-ambient thermal resistance (DCK, SC70) | RθJA |  | 227.3 |  | °C/W |  | 6 |+| Junction-to-case (top) thermal resistance (DCK, SC70) | RθJC(top) |  | 79.5 |  | °C/W |  | 6 |+| Junction-to-board thermal resistance (DCK, SC70) | RθJB |  | 72.1 |  | °C/W |  | 6 |+| Junction-to-top characterization parameter (DCK, SC70) | ψJT |  | 3.6 |  | °C/W |  | 6 |+| Junction-to-board characterization parameter (DCK, SC70) | ψJB |  | 70.4 |  | °C/W |  | 6 |+| Thermal resistance (SC70) | θJA |  | 250 |  | °C/W |  | 7 |+| Gain, INA199x2 | G |  | 100 |  | V/V | INA199x2 | 7 |+ ## CAD (KiCad official)  - Symbol: `INA199B2DCKR`
page.json+441
@@ -152,5 +152,446 @@         "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"       }     ]+  },+  "metadata": {+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": null,+      "rows": [+        {+          "name": "Gain error (Version A and B)",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -1.5,+          "typ": 0.03,+          "max": 1.5,+          "conditions": "Version A and B, VSENSE = –5 mV to 5 mV, TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Gain error vs temperature",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 3,+          "max": 10,+          "conditions": "TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input range",+          "symbol": "VCM",+          "kind": "electrical",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 26,+          "conditions": "Version B and C, TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Common-mode rejection",+          "symbol": "CMR",+          "kind": "electrical",+          "unit": "dB",+          "min": 100,+          "typ": 120,+          "max": null,+          "conditions": "VIN+ = 0 V to 26 V, VSENSE = 0 mV, TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Offset voltage, RTI",+          "symbol": "VOS",+          "kind": "tolerance",+          "unit": "μV",+          "min": -150,+          "typ": 5,+          "max": 150,+          "conditions": "VSENSE = 0 mV",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "VOS vs temperature",+          "symbol": "dVOS/dT",+          "kind": "temperature_coefficient",+          "unit": "μV/°C",+          "min": null,+          "typ": 0.1,+          "max": 0.5,+          "conditions": "TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Maximum capacitive load",+          "symbol": "CLOAD",+          "kind": "electrical",+          "unit": "nF",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "No sustained oscillation",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Swing to V+ power-supply rail",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.05,+          "max": 0.2,+          "conditions": "RL = 10 kΩ to GND, TA = –40°C to 125°C; printed as (V+) – x V",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Swing to GND",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": 0.005,+          "max": 0.05,+          "conditions": "RL = 10 kΩ to GND, TA = –40°C to 125°C; printed as (VGND) + x V",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Operating voltage range",+          "symbol": "VS",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.7,+          "typ": null,+          "max": 26,+          "conditions": "TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Operating voltage range",+          "symbol": "VS",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.5,+          "typ": null,+          "max": 26,+          "conditions": "–20°C to 85°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Quiescent current",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 65,+          "max": 100,+          "conditions": "VSENSE = 0 mV",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Quiescent current over temperature",+          "symbol": "IQ",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 115,+          "conditions": "TA = –40°C to 125°C",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Specified temperature range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range (electrical table)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Supply voltage",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 26,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Differential analog input (VIN+) – (VIN–)",+          "symbol": "VIN+, VIN–",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -26,+          "typ": null,+          "max": 26,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Common-mode analog input, INA199Bx and INA199Cx",+          "symbol": "VIN+, VIN–",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 26,+          "conditions": "Referenced to GND (GND – 0.1 V to 26 V)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "REF input voltage",+          "symbol": "VREF",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "Min referenced to GND (GND – 0.3 V); max referenced to V+ ((V+) + 0.3 V)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output voltage",+          "symbol": "VOUT",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "Min referenced to GND (GND – 0.3 V); max referenced to V+ ((V+) + 0.3 V)",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input current into all pins",+          "symbol": "IIN",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Electrostatic discharge, human-body model (INA199Bx, INA199Cx in DCK and RSW)",+          "symbol": "V(ESD)",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -3500,+          "typ": null,+          "max": 3500,+          "conditions": "HBM per ANSI/ESDA/JEDEC JS-001",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Electrostatic discharge, charged-device model (INA199Bx, INA199Cx in DCK and RSW)",+          "symbol": "V(ESD)",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -1000,+          "typ": null,+          "max": 1000,+          "conditions": "CDM per JEDEC JESD22-C101",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Common-mode input voltage",+          "symbol": "VCM",+          "kind": "recommended_operating",+          "unit": "V",+          "min": null,+          "typ": 12,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Operating supply voltage (applied to V+)",+          "symbol": "VS",+          "kind": "recommended_operating",+          "unit": "V",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance (DCK, SC70)",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 227.3,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (top) thermal resistance (DCK, SC70)",+          "symbol": "RθJC(top)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 79.5,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board thermal resistance (DCK, SC70)",+          "symbol": "RθJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 72.1,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-top characterization parameter (DCK, SC70)",+          "symbol": "ψJT",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 3.6,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board characterization parameter (DCK, SC70)",+          "symbol": "ψJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 70.4,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance (SC70)",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 250,+          "max": null,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Gain, INA199x2",+          "symbol": "G",+          "kind": "electrical",+          "unit": "V/V",+          "min": null,+          "typ": 100,+          "max": null,+          "conditions": "INA199x2",+          "source_page": 7,+          "source": "datasheet"+        }+      ]+    }   } }