← Commit history
package.json+639−4@@ -1,6 +1,6 @@ { "slug": "hf920gse-z",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Monolithic Power Systems AC-DC Controllers & Regulators, SOIC-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "hf920gse-z-hero.glb", "hf920gse-z-hero.overlay.json",- "hf920gse-z-etched.glb"+ "hf920gse-z-etched.glb",+ "hf920gse-z-etched.step" ], "component": { "mpn": "HF920GSE-Z",@@ -43,7 +44,7 @@ "symbol": "hf920gse-z.kicad_sym", "footprint": "hf920gse-z.kicad_mod", "model_3d": "hf920gse-z-hero.glb",- "model_3d_plain": "hf920gse-z-etched.glb",+ "model_3d_plain": "hf920gse-z.glb", "model_3d_step": "hf920gse-z-etched.step", "model_3d_step_plain": "hf920gse-z.step", "lbr": "hf920gse-z.lbr"@@ -185,5 +186,639 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "HF920GSE-Z",+ "brief": "Monolithic Power Systems AC-DC Controllers & Regulators, SOIC-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Monolithic Power Systems",+ "Package": "SOIC-7",+ "Category": "Power Management",+ "Pins": "7"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "f0063d4ce412f57e9b4332d207731a8d098e990952fbfeee232eb05f52d48b26",+ "rows": [+ {+ "name": "Supply current from drain",+ "symbol": "ICharge",+ "kind": "electrical",+ "unit": "mA",+ "min": 1,+ "typ": 2,+ "max": 3,+ "conditions": "VCC = VCCH - 0.1V, VD = 400V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Leakage current from drain (TJ=25°C)",+ "symbol": "ILeak",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VD = 400V, VGS = 0V, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Leakage current from drain",+ "symbol": "ILeak",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "VD = 400V, VGS = 0V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Breakdown voltage",+ "symbol": "V(BR)DSS",+ "kind": "electrical",+ "unit": "V",+ "min": 900,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "On-state resistance (TJ=25°C)",+ "symbol": "RDS(ON)",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 15,+ "max": 18,+ "conditions": "VCC = 10V, ID = 100mA, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "On-state resistance (TJ=125°C)",+ "symbol": "RDS(ON)",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 25,+ "max": 29,+ "conditions": "VCC = 10V, ID = 100mA, TJ = 125°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC upper level at which the IC switch turns on",+ "symbol": "VCCH",+ "kind": "electrical",+ "unit": "V",+ "min": 12,+ "typ": 13,+ "max": 14,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC lower level at which the IC switch turns off",+ "symbol": "VCCL",+ "kind": "electrical",+ "unit": "V",+ "min": 8.4,+ "typ": 9,+ "max": 9.6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC hysteresis",+ "symbol": "VCC_HYS",+ "kind": "electrical",+ "unit": "V",+ "min": 3,+ "typ": 4,+ "max": 5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC OVP level",+ "symbol": "VOVP",+ "kind": "electrical",+ "unit": "V",+ "min": 24.4,+ "typ": 25.5,+ "max": 26.5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC recharge level after protections",+ "symbol": "VCCR",+ "kind": "electrical",+ "unit": "V",+ "min": 4.8,+ "typ": 5.5,+ "max": 6.2,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current during protections",+ "symbol": "IPro",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "VCC = VCCL",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "IQ",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 200,+ "max": 300,+ "conditions": "VCC = VCCH - 0.1V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operation current",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 510,+ "max": 610,+ "conditions": "VCC =13V, fS = 100kHz",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operation current",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 300,+ "max": 400,+ "conditions": "VCC = 13V, FB = 0V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Internal pull-up voltage",+ "symbol": "VUP",+ "kind": "electrical",+ "unit": "V",+ "min": 4.1,+ "typ": 4.4,+ "max": 4.7,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB to current-set-point division ratio",+ "symbol": "Kdiv",+ "kind": "electrical",+ "unit": "",+ "min": 3.4,+ "typ": null,+ "max": 3.7,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB decreasing level at which the regulator enters burst mode",+ "symbol": "VBURL",+ "kind": "electrical",+ "unit": "V",+ "min": 0.4,+ "typ": 0.5,+ "max": 0.6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB increasing level at which the regulator leaves burst mode",+ "symbol": "VBURH",+ "kind": "electrical",+ "unit": "V",+ "min": 0.6,+ "typ": 0.7,+ "max": 0.8,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Overload set point",+ "symbol": "VOLP",+ "kind": "electrical",+ "unit": "V",+ "min": 3.3,+ "typ": 3.65,+ "max": 4,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Threshold for frequency to recover",+ "symbol": "VFR",+ "kind": "electrical",+ "unit": "V",+ "min": 2.85,+ "typ": 3,+ "max": 3.15,+ "conditions": "CFSET = 1nF",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FSET reference voltage",+ "symbol": "VFSET",+ "kind": "electrical",+ "unit": "V",+ "min": 1.18,+ "typ": 1.25,+ "max": 1.32,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Typical operating frequency",+ "symbol": "fS",+ "kind": "electrical",+ "unit": "kHz",+ "min": 43,+ "typ": 49,+ "max": 55,+ "conditions": "RFSET = 200kΩ",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Typical operating frequency",+ "symbol": "fS",+ "kind": "electrical",+ "unit": "kHz",+ "min": 87,+ "typ": 99,+ "max": 111,+ "conditions": "RFSET = 200kΩ, CFSET = 1nF, VFB = 3.5V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum switching duty",+ "symbol": "Dmax",+ "kind": "electrical",+ "unit": "%",+ "min": 79,+ "typ": 83,+ "max": 87,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum current set point",+ "symbol": "VCSL",+ "kind": "electrical",+ "unit": "V",+ "min": 0.91,+ "typ": 0.97,+ "max": 1.02,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Short-circuit protection set point",+ "symbol": "VSCP",+ "kind": "electrical",+ "unit": "V",+ "min": 1.43,+ "typ": 1.5,+ "max": 1.57,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Protection voltage",+ "symbol": "VPRO",+ "kind": "electrical",+ "unit": "V",+ "min": 2.92,+ "typ": 3.1,+ "max": 3.32,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC to GND",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 10,+ "typ": null,+ "max": 24,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "D pin voltage",+ "symbol": "D",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 900,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC pin voltage",+ "symbol": "VCC",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 30,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "All other pins",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Continuous power dissipation SOIC8-7A",+ "symbol": "PD",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 1.3,+ "conditions": "TA = +25°C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Lead temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -60,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ESD human body model",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "kV",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "ESD charged device model",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "kV",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-ambient SOIC8-7A",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 96,+ "max": null,+ "conditions": "JESD51-7, 4-layer PCB",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-case SOIC8-7A",+ "symbol": "θJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 45,+ "max": null,+ "conditions": "JESD51-7, 4-layer PCB",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Internal pull-up resistor",+ "symbol": "RFB",+ "kind": "electrical",+ "unit": "kΩ",+ "min": null,+ "typ": 39,+ "max": null,+ "conditions": "Normal operating",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Internal soft-start time",+ "symbol": "tSS",+ "kind": "timing",+ "unit": "ms",+ "min": null,+ "typ": 6.7,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC OVP delay time",+ "symbol": "tOVP",+ "kind": "timing",+ "unit": "μs",+ "min": null,+ "typ": 70,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Frequency jittering range",+ "symbol": "RJittering",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 3.5,+ "max": null,+ "conditions": "in percentage of Fs, ±",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Leading-edge blanking for current sensor",+ "symbol": "tLEB1",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": 385,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Leading-edge blanking for SCP",+ "symbol": "tLEB2",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": 350,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Slope compensation ramp",+ "symbol": "SRamp",+ "kind": "electrical",+ "unit": "mV/μs",+ "min": null,+ "typ": 21,+ "max": null,+ "conditions": "RFSET = 200kΩ",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Protection hysteresis",+ "symbol": "VPRO-Hys",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.2,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Thermal shutdown threshold",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": 150,+ "max": null,+ "conditions": "guaranteed by design",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Thermal shutdown recovery hysteresis",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": 30,+ "max": null,+ "conditions": "guaranteed by design",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "hf920gse-z"+ ],+ "discovery_pitch": "HF920GSE-Z (Monolithic Power Systems) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "hf920gse-z", "title": "HF920GSE-Z", "brief": "Monolithic Power Systems AC-DC Controllers & Regulators, SOIC-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "hf920gse-z.kicad_sym", "footprint": "hf920gse-z.kicad_mod", "model_3d": "hf920gse-z-hero.glb",- "model_3d_plain": "hf920gse-z-etched.glb",+ "model_3d_plain": "hf920gse-z.glb", "model_3d_step": "hf920gse-z-etched.step", "model_3d_step_plain": "hf920gse-z.step", "lbr": "hf920gse-z.lbr"@@ -830,9 +830,10 @@ "viewers/footprint.html", "hf920gse-z-hero.glb", "hf920gse-z-hero.overlay.json",- "hf920gse-z-etched.glb"+ "hf920gse-z-etched.glb",+ "hf920gse-z-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Monolithic Power Systems AC-DC Controllers & Regulators, SOIC-7. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }