main
Ray
hef40106bt: component.models_3d pose record per STEP (Z-up, seated z=0, pad-centre origin, identity binding)
5e2854e
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243
{
"schema_version": 1,
"type": "component",
"slug": "hef40106bt",
"title": "HEF40106BT",
"brief": "Nexperia Inverters, SOIC-14. Pinout extracted from the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"logic",
"hef40106bt"
],
"component": {
"mpn": "HEF40106BT",
"manufacturer": "Nexperia",
"package": "SOIC-14",
"pin_count": 14,
"category": "Logic",
"subcategory": "Inverters",
"datasheet": "https://assets.nexperia.com/documents/data-sheet/HEF40106BT.pdf",
"parts": {
"symbol": "hef40106bt.kicad_sym",
"footprint": "hef40106bt.kicad_mod",
"model_3d": "hef40106bt-etched.glb",
"model_3d_plain": "hef40106bt.glb",
"model_3d_step": "hef40106bt-etched.step",
"model_3d_step_plain": "hef40106bt.step",
"lbr": "hef40106bt.lbr"
},
"distributor_links": {},
"pins": [
{
"number": "1",
"name": "1A",
"type": "input",
"description": "Schmitt-trigger input of inverter 1. Includes input clamp diodes to VDD and VSS; VI range 0 V to VDD; typical positive-going threshold VT+ = 3.0 V at VDD = 5 V, negative-going threshold VT- = 2.2 V."
},
{
"number": "2",
"name": "1Y",
"type": "output",
"description": "Inverted output of inverter 1. CMOS push-pull output; IOH ~ -1.4 mA at VO = 2.5 V, VDD = 5 V; IOL ~ 0.5 mA at VO = 0.4 V, VDD = 5 V."
},
{
"number": "3",
"name": "2A",
"type": "input",
"description": "Schmitt-trigger input of inverter 2. Includes input clamp diodes to VDD and VSS."
},
{
"number": "4",
"name": "2Y",
"type": "output",
"description": "Inverted output of inverter 2. CMOS push-pull output."
},
{
"number": "5",
"name": "3A",
"type": "input",
"description": "Schmitt-trigger input of inverter 3. Includes input clamp diodes to VDD and VSS."
},
{
"number": "6",
"name": "3Y",
"type": "output",
"description": "Inverted output of inverter 3. CMOS push-pull output."
},
{
"number": "7",
"name": "VSS",
"type": "power_in",
"description": "Ground (0 V) reference. Negative supply rail; all voltages referenced to VSS."
},
{
"number": "8",
"name": "4Y",
"type": "output",
"description": "Inverted output of inverter 4. CMOS push-pull output."
},
{
"number": "9",
"name": "4A",
"type": "input",
"description": "Schmitt-trigger input of inverter 4. Includes input clamp diodes to VDD and VSS."
},
{
"number": "10",
"name": "5Y",
"type": "output",
"description": "Inverted output of inverter 5. CMOS push-pull output."
},
{
"number": "11",
"name": "5A",
"type": "input",
"description": "Schmitt-trigger input of inverter 5. Includes input clamp diodes to VDD and VSS."
},
{
"number": "12",
"name": "6Y",
"type": "output",
"description": "Inverted output of inverter 6. CMOS push-pull output."
},
{
"number": "13",
"name": "6A",
"type": "input",
"description": "Schmitt-trigger input of inverter 6. Includes input clamp diodes to VDD and VSS."
},
{
"number": "14",
"name": "VDD",
"type": "power_in",
"description": "Positive supply voltage. Operating range 3.0 V to 15.0 V; absolute maximum 18 V. Supply current IDD typ 0.25 uA at VDD = 5 V (static)."
}
],
"provenance": {
"extractor": "ds2sf",
"datasheet": {
"url": "https://assets.nexperia.com/documents/data-sheet/HEF40106BT.pdf",
"pages": 14,
"sha256": "385d3a3085506d62",
"source_tier": "mfr"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 14,
"described": 14,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"logic": {
"family_id": "CD40106",
"logic_family": "CD4000",
"function_code": "40106",
"function_class": "Gate",
"function_name": "Hex Schmitt-Trigger Inverter",
"manufacturer": "NXP (legacy Philips)",
"is_specialty": false
},
"models_3d": [
{
"file": "hef40106bt.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
8.7,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "3b9a775da256c8afcc28dcddfbc2eb3f266107fe61ce8446d96f2c52b6f44a70",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "hef40106bt-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
6,
8.7,
1.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "433a404047f61640f4fd29497e37c9eb98f58ec939dd1f97b1d24745c0243f22",
"checked": "2026-10-07",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "Nexperia",
"Package": "SOIC-14",
"Category": "Logic",
"Pins": "14"
}
},
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"hef40106bt"
],
"discovery_pitch": "HEF40106BT (Nexperia) component page with datasheet-verified CAD.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"hef40106bt.kicad_sym",
"hef40106bt.kicad_mod",
"hef40106bt.glb",
"hef40106bt.step",
"hef40106bt.lbr",
"docs/hero.png",
"docs/hef40106bt-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"hef40106bt-etched.step"
],
"visibility": {
"public": true
},
"variants": [
{
"mpn": "HEF40106BT",
"kind": "packaging"
},
{
"mpn": "HEF40106BTT",
"kind": "packaging"
}
],
"updated_at": "2026-09-24T21:41:09.542Z"
}