h7210-25m5r: specified limits as data (metadata.characteristics, 14 rows from the datasheet)
2 files changed
+196
README.md+21@@ -29,6 +29,27 @@ Same part, different packaging or reel option. - `H7210-25M5R` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Output voltage accuracy | Vout | -2 | | 2 | % | | 1 |+| Line Regulation | △Vout1/ (△Vin·Vout) | | 0.05 | 0.2 | %/V | 4.3V≤Vin≤8V, Iout=10mA | 4 |+| Load Regulation | △Vout | | 10 | 30 | mV | Vin= 4.3V, 1.0mA≤Iout≤100mA | 4 |+| Output voltage Temperature Coefficiency | △Vout/(Ta·Vout) | -100 | | 100 | Ppm/℃ | Iout=30mA, 0℃≤Ta≤70℃ | 4 |+| Supply Current | Iss | | 5 | 30 | uA | | 4 |+| Input Voltage | Vin | | | 6 | V | | 4 |+| En input voltage | | 0 | | 5.5 | V | unless otherwise indicated, TA = 25 °C | 3 |+| Junction temperature range | | -40 | | 125 | ℃ | | 3 |+| Ambient temperature range | | -40 | | 85 | ℃ | | 3 |+| Supply Voltage | | -0.3 | | 8 | V | | 3 |+| Storage Temperature | | -50 | | 125 | ℃ | | 3 |+| Operating Temperature | | -40 | | 85 | ℃ | | 3 |+| Thermal Resistance (Junction to Ambient), SOT23-5 | θJA | | | 500 | ℃/W | Assume no ambient airflow, no heat sink | 3 |+| Power Dissipation, SOT23-5 | PD | | | 0.25 | W | PD is measured at Ta= 25℃ | 3 |+ ## CAD (KiCad official) - Symbol: `H7210-25M5R`
page.json+175@@ -128,6 +128,181 @@ "Package": "SOT-23-5", "Category": "PMIC", "Pins": "5"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "d68700857f3166ee",+ "rows": [+ {+ "name": "Output voltage accuracy",+ "symbol": "Vout",+ "kind": "tolerance",+ "unit": "%",+ "min": -2,+ "typ": null,+ "max": 2,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Line Regulation",+ "symbol": "△Vout1/ (△Vin·Vout)",+ "kind": "electrical",+ "unit": "%/V",+ "min": null,+ "typ": 0.05,+ "max": 0.2,+ "conditions": "4.3V≤Vin≤8V, Iout=10mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Load Regulation",+ "symbol": "△Vout",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 10,+ "max": 30,+ "conditions": "Vin= 4.3V, 1.0mA≤Iout≤100mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output voltage Temperature Coefficiency",+ "symbol": "△Vout/(Ta·Vout)",+ "kind": "temperature_coefficient",+ "unit": "Ppm/℃",+ "min": -100,+ "typ": null,+ "max": 100,+ "conditions": "Iout=30mA, 0℃≤Ta≤70℃",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply Current",+ "symbol": "Iss",+ "kind": "electrical",+ "unit": "uA",+ "min": null,+ "typ": 5,+ "max": 30,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Voltage",+ "symbol": "Vin",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "En input voltage",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 5.5,+ "conditions": "unless otherwise indicated, TA = 25 °C",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Ambient temperature range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 8,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "℃",+ "min": -50,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating Temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "℃",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance (Junction to Ambient), SOT23-5",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "℃/W",+ "min": null,+ "typ": null,+ "max": 500,+ "conditions": "Assume no ambient airflow, no heat sink",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation, SOT23-5",+ "symbol": "PD",+ "kind": "thermal",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 0.25,+ "conditions": "PD is measured at Ta= 25℃",+ "source_page": 3,+ "source": "datasheet"+ }+ ] } }, "sections": [