main
Ray
Set visibility: public
36a755d
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333
{
"schema_version": 1,
"type": "component",
"slug": "gsot05c-e3-08",
"title": "GSOT05C-E3-08",
"brief": "UMW ESD And Surge Protection (TVS/ESD), SOT-23. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"circuit protection",
"gsot05c-e3-08",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "GSOT05C-E3-08",
"manufacturer": "UMW",
"package": "SOT-23",
"pin_count": 3,
"category": "Circuit Protection",
"subcategory": "ESD And Surge Protection (TVS/ESD)",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/4eb468f5b994a6d58f73196a2c5d9494.pdf",
"parts": {
"symbol": "gsot05c-e3-08.kicad_sym",
"footprint": "gsot05c-e3-08.kicad_mod",
"model_3d": "gsot05c-e3-08-hero.glb",
"model_3d_plain": "gsot05c-e3-08.glb",
"model_3d_step": "gsot05c-e3-08-etched.step",
"model_3d_step_plain": "gsot05c-e3-08.step",
"lbr": "gsot05c-e3-08.lbr"
},
"distributor_links": {
"lcsc": "C7588064",
"digikey": "GSOT05C-E3-08TR-ND",
"mouser": "78-GSOT05C-E3-08"
},
"distributor_check": {
"checked_at": "2026-11-20T21:17:15Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "GSOT05C-E3-08TR-ND",
"status": "found"
},
"mouser": {
"pn": "78-GSOT05C-E3-08",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "L1",
"type": "passive",
"description": "Protected signal or data line; in BiAs mode it is clamped to pin 3 with a max reverse working voltage of 5 V and ESD immunity of ±30 kV (contact and air, IEC 61000-4-2), and in BiSy mode it is the single protected line with pin 2 as ground."
},
{
"number": "2",
"name": "L2",
"type": "passive",
"description": "Second protected signal or data line in BiAs mode, with the same limits as pin 1 (max reverse working voltage 5 V, ESD ±30 kV contact/air); in BiSy mode it is used as the ground connection and pin 1 is the line."
},
{
"number": "3",
"name": "Ground",
"type": "power_in",
"description": "Common ground reference for the two-line BiAs protection; it is connected to ground in BiAs mode and must be left unconnected in BiSy mode, where pin 2 is used as ground."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-haiku-5-5",
"primary_mode": "text",
"consensus_model": "claude-sonnet-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: The datasheet does not print functional pin names for the SOT-23 pins. The names 'L1', 'L2' and 'GND; Pin 2 changes role by application mode: in BiAs mode it is a protected line, while in BiSy mode it i; The SOT-23 pinning diagram text is garbled in the extracted text. Pin numbers 1, 2 and 3 are taken f",
"1/3 pins cited to the wrong page (name found elsewhere): ['2:L2@p9']"
],
"pages_sent": 21,
"cost_usd": 0.0237,
"at": "2026-11-20T21:17:07"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/4eb468f5b994a6d58f73196a2c5d9494.pdf",
"pages": 21,
"sha256": "0b440e1da93472e0",
"source_tier": "lcsc",
"citation": "UMW datasheet, copy hosted by LCSC"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 3,
"described": 3,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "gsot05c-e3-08.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2.5,
3,
1.2
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "dd5d1711204e1d8d26cd11490923bd84340820baa69538c385a4300ec2539bc0",
"checked": "2026-11-20",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "gsot05c-e3-08-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
2.5,
3,
1.2
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "2a2401dac7dfc3daef8da3bc4050783c45a24e58b185749335457be41ca35357",
"checked": "2026-11-20",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "UMW",
"Package": "SOT-23",
"Category": "Circuit Protection",
"Pins": "3"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "0b440e1da93472e0adb4ba4db021f4613a13ec9b293ed33820f0ac7c87bccc86",
"rows": [
{
"name": "Max. reverse working voltage (reverse stand-off voltage)",
"symbol": "VRWM",
"kind": "electrical",
"unit": "V",
"min": null,
"typ": null,
"max": 5,
"conditions": "",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Reverse breakdown voltage",
"symbol": "VBR",
"kind": "electrical",
"unit": "V",
"min": 6,
"typ": 6.8,
"max": 7,
"conditions": "at IR=1mA; pin 1 to 3 or pin 2 to 3",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Capacitance",
"symbol": "CD",
"kind": "electrical",
"unit": "pF",
"min": null,
"typ": null,
"max": 260,
"conditions": "at VR=0V, f=1MHz; pin 1 to 3 or pin 2 to 3",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Capacitance",
"symbol": "CD",
"kind": "electrical",
"unit": "pF",
"min": null,
"typ": null,
"max": 150,
"conditions": "at VR=2.5V, f=1MHz; pin 1 to 3 or pin 2 to 3",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Peak pulse current",
"symbol": "IPPM",
"kind": "absolute_maximum",
"unit": "A",
"min": null,
"typ": null,
"max": 30,
"conditions": "Pin 1 to 3 or pin 2 to 3; acc. IEC 61000-4-5, tp=8/20μs; single shot",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Peak pulse power",
"symbol": "PPP",
"kind": "absolute_maximum",
"unit": "W",
"min": null,
"typ": null,
"max": 480,
"conditions": "Pin 1 to 3 or pin 2 to 3; acc. IEC 61000-4-5, tp=8/20μs; single shot",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Peak pulse power",
"symbol": "PPP",
"kind": "absolute_maximum",
"unit": "W",
"min": null,
"typ": null,
"max": 612,
"conditions": "Pin 1 to 2 or pin 2 to 1; pin 3 not connected; acc. IEC 61000-4-5, tp=8/20μs; single shot",
"source_page": 2,
"source": "datasheet"
},
{
"name": "ESD immunity contact discharge",
"symbol": "VESD",
"kind": "absolute_maximum",
"unit": "kV",
"min": -30,
"typ": null,
"max": 30,
"conditions": "Contact discharge acc. IEC 61000-4-2; 10 pulses",
"source_page": 2,
"source": "datasheet"
},
{
"name": "ESD immunity air discharge",
"symbol": "VESD",
"kind": "absolute_maximum",
"unit": "kV",
"min": -30,
"typ": null,
"max": 30,
"conditions": "Air discharge acc. IEC 61000-4-2; 10 pulses",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Junction temperature",
"symbol": "TJ",
"kind": "absolute_maximum",
"unit": "°C",
"min": -55,
"typ": null,
"max": 150,
"conditions": "",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Storage temperature",
"symbol": "TSTG",
"kind": "absolute_maximum",
"unit": "°C",
"min": -55,
"typ": null,
"max": 150,
"conditions": "",
"source_page": 2,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"gsot05c-e3-08"
],
"discovery_pitch": "GSOT05C-E3-08 (UMW) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"gsot05c-e3-08.kicad_sym",
"gsot05c-e3-08.kicad_mod",
"gsot05c-e3-08.glb",
"gsot05c-e3-08.step",
"gsot05c-e3-08.lbr",
"docs/hero.png",
"docs/gsot05c-e3-08-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"gsot05c-e3-08-hero.glb",
"gsot05c-e3-08-hero.overlay.json"
],
"visibility": {