← Commit history

gcm1555c1h471fa16d: factory component page (tier=lcsc)

Ray ·992b159376 ·20d ago ·parent 1fe89d6
1 file changed +523−29
page.json+523−29
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "gcm1555c1h471fa16d",+  "title": "GCM1555C1H471FA16D",+  "brief": "MURATA ELECTRONICS Global Sourcing Parts, 0402. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "MURATA ELECTRONICS Global Sourcing Parts, 0402. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "global sourcing parts",@@ -10,26 +13,6 @@     "factory-2.0.0",     "extractor-text"   ],-  "dependencies": {},-  "hero": {-    "type": "image",-    "path": "docs/hero.png"-  },-  "files": [-    "page.json",-    "README.md",-    "gcm1555c1h471fa16d.kicad_sym",-    "gcm1555c1h471fa16d.kicad_mod",-    "gcm1555c1h471fa16d.glb",-    "gcm1555c1h471fa16d.step",-    "gcm1555c1h471fa16d.lbr",-    "docs/hero.png",-    "docs/gcm1555c1h471fa16d-datasheet.pdf",-    "viewers/symbol.html",-    "viewers/footprint.html",-    "gcm1555c1h471fa16d-hero.glb",-    "gcm1555c1h471fa16d-hero.overlay.json"-  ],   "component": {     "mpn": "GCM1555C1H471FA16D",     "manufacturer": "MURATA ELECTRONICS",@@ -119,12 +102,12 @@         "origin": "footprint origin = pad-pattern centre",         "seat": "z = 0",         "extents_mm": [-          1,+          1.0,           0.5,           0.5         ],-        "zmin_mm": 0,-        "centre_offset_mm": 0,+        "zmin_mm": 0.0,+        "centre_offset_mm": 0.0,         "footprint_binding": "identity",         "sha256": "03e44c4b2b727b8d4b6b1fd598cbd12dd5e614f1dfeefa96a92a07e3a3b312a2",         "checked": "2026-10-17",@@ -132,10 +115,521 @@       }     ]   },-  "visibility": "public",-  "org": "adom",+  "metadata": {+    "specs": {+      "Manufacturer": "MURATA ELECTRONICS",+      "Package": "0402",+      "Category": "Global Sourcing Parts",+      "Pins": "2"+    },+    "appearance": {+      "contacts": {+        "quote": "Please contact our sales representative or product engineers on the use of Sn-Zn based solder in advance. Caution",+        "page": 14,+        "doc": "ds.pdf",+        "plating": "tin"+      },+      "version": 1,+      "datasheet_sha256": "df21d96d3852dc0f33a64a08a29d1c47835eef512fc980ed6e7d677726325fff"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "df21d96d3852dc0f33a64a08a29d1c47835eef512fc980ed6e7d677726325fff",+      "rows": [+        {+          "name": "Capacitance tolerance (code F)",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -1,+          "typ": null,+          "max": 1,+          "conditions": "Part-number tolerance code F",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Temperature coefficient",+          "symbol": "TC",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": -30,+          "typ": 0,+          "max": 30,+          "conditions": "25 to 125 °C (ref. 25 °C)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Capacitance change from 25 °C at -55 °C (5C/5G)",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "%",+          "min": -0.24,+          "typ": null,+          "max": 0.58,+          "conditions": "Table A, 5C/5G, Max./Min. from 25 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Capacitance change from 25 °C at -30 °C (5C/5G)",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "%",+          "min": -0.17,+          "typ": null,+          "max": 0.4,+          "conditions": "Table A, 5C/5G, Max./Min. from 25 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Capacitance change from 25 °C at -10 °C (5C/5G)",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "%",+          "min": -0.11,+          "typ": null,+          "max": 0.25,+          "conditions": "Table A, 5C/5G, Max./Min. from 25 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Capacitance drift",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "%",+          "min": -0.2,+          "typ": null,+          "max": 0.2,+          "conditions": "-55 °C to +150 °C; ±0.2% or ±0.05 pF, whichever is larger",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Q (30 pF min.)",+          "symbol": "Q",+          "kind": "electrical",+          "unit": "",+          "min": 1000,+          "typ": null,+          "max": null,+          "conditions": "30 pF min., 25 °C, freq/voltage per Electrical Characteristics table",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Insulation resistance at 25 °C",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 100000,+          "typ": null,+          "max": null,+          "conditions": "25 °C, DC ≤ rated voltage, 2 min charge; or 1000 Ω·F, whichever is smaller",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Insulation resistance at 125 °C",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "125 °C (5C); or 100 Ω·F, whichever is smaller",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Rated voltage",+          "symbol": "VR",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "DC; applied voltage must not exceed rated voltage",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range",+          "symbol": "TOP",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 125,+          "conditions": "Operating temp. range",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 5,+          "typ": null,+          "max": 40,+          "conditions": "Room temperature storage, per Caution 1-1",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Storage relative humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%RH",+          "min": 20,+          "typ": null,+          "max": 70,+          "conditions": "Storage, per Caution 1-1",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature (lead-free)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 240,+          "typ": null,+          "max": 260,+          "conditions": "Sn-3.0Ag-0.5Cu, air or N2; Table 1",+          "source_page": 16,+          "source": "datasheet"+        },+        {+          "name": "Reflow temperature differential ΔT",+          "symbol": "ΔT",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 190,+          "conditions": "Reflow, chip 03/15/18/21/31",+          "source_page": 16,+          "source": "datasheet"+        },+        {+          "name": "Soldering iron tip temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 350,+          "conditions": "Rework, GC□03/15/18/21/31, air",+          "source_page": 18,+          "source": "datasheet"+        },+        {+          "name": "Preheating temperature (rework)",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 150,+          "typ": null,+          "max": null,+          "conditions": "Rework, GC□03/15/18/21/31, air",+          "source_page": 18,+          "source": "datasheet"+        },+        {+          "name": "High temp. exposure capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -2.5,+          "typ": null,+          "max": 2.5,+          "conditions": "150 °C 1000 h; ±2.5% or ±0.25 pF, whichever is larger",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "High temp. exposure insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Temperature cycling capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -2.5,+          "typ": null,+          "max": 2.5,+          "conditions": "±2.5% or ±0.25 pF, whichever is larger",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Temperature cycling insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Moisture resistance capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -3,+          "typ": null,+          "max": 3,+          "conditions": "±3.0% or ±0.30 pF, whichever is larger",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Moisture resistance Q (30 pF min.)",+          "symbol": "Q",+          "kind": "electrical",+          "unit": "",+          "min": 350,+          "typ": null,+          "max": null,+          "conditions": "30 pF min.",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Moisture resistance insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Biased humidity capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -3,+          "typ": null,+          "max": 3,+          "conditions": "±3.0% or ±0.30 pF, whichever is larger",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Biased humidity Q (30 pF and over)",+          "symbol": "Q",+          "kind": "electrical",+          "unit": "",+          "min": 200,+          "typ": null,+          "max": null,+          "conditions": "30 pF and over",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Biased humidity insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 1000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 50 Ω·F, whichever is smaller",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operational life capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -3,+          "typ": null,+          "max": 3,+          "conditions": "125 °C, 200% rated voltage, 1000 h; ±3.0% or ±0.30 pF, whichever is larger",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operational life Q (30 pF min.)",+          "symbol": "Q",+          "kind": "electrical",+          "unit": "",+          "min": 350,+          "typ": null,+          "max": null,+          "conditions": "30 pF min.",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operational life insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 1000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 50 Ω·F, whichever is smaller",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Resistance to solvents insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Mechanical shock insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Resistance to soldering heat insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -2.5,+          "typ": null,+          "max": 2.5,+          "conditions": "±2.5% or ±0.25 pF, whichever is larger",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "ESD insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Board flex capacitance change",+          "symbol": "ΔC",+          "kind": "electrical",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "±5.0% or ±0.5 pF, whichever is larger",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Board flex insulation resistance",+          "symbol": "IR",+          "kind": "electrical",+          "unit": "MΩ",+          "min": 10000,+          "typ": null,+          "max": null,+          "conditions": "25 °C; or 500 Ω·F, whichever is smaller",+          "source_page": 5,+          "source": "datasheet"+        }+      ]+    }+  },+  "variants": [],+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "gcm1555c1h471fa16d"+  ],+  "discovery_pitch": "GCM1555C1H471FA16D (MURATA ELECTRONICS) component page: datasheet pinout, KiCad symbol, footprint and 3D.",   "author": {     "name": "Ray",     "email": "[email protected]"-  }-}\ No newline at end of file+  },+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "gcm1555c1h471fa16d.kicad_sym",+    "gcm1555c1h471fa16d.kicad_mod",+    "gcm1555c1h471fa16d.glb",+    "gcm1555c1h471fa16d.step",+    "gcm1555c1h471fa16d.lbr",+    "docs/hero.png",+    "docs/gcm1555c1h471fa16d-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "gcm1555c1h471fa16d-hero.glb",+    "gcm1555c1h471fa16d-hero.overlay.json"+  ]+}