warmup: waking the bridge (unscored)...
  fusion_readiness                           PASS 
  fusion_prewarm                             PASS 
  fusion_account                             PASS 
  fusion_describe                            PASS 
  fusion_get_app_state                       FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_search_cloud_files                  PASS 
  fusion_walk_cloud_tree                     PASS 
  fusion_aps_status                          PASS 
  fusion_aps_get_browser                     PASS 
  fusion_aps_search                          PASS 
  fusion_aps_recent                          PASS 
  fusion_aps_browse                          PASS 
  fusion_aps_file_info                       PASS 
  fusion_aps_get                             PASS 
  fusion_uninstall                           PASS 
  fusion_set_seat_takeover                   PASS 
  fusion_start                               FAIL - expected success, got error='fusion_start' did not respond within ab's 90s budget. code=timed_out
  fusion_get_preferences                     FAIL - expected success, got error=Add-in request failed: http://127.0.0.1:8774/command: Connection Failed: Connect code=None; missing field 'current'
  fusion_set_preference                      FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=None
  fusion_mcp_status                          PASS 
  fusion_set_auto_update                     PASS 
  fusion_assembly_bom                        FAIL - expected a BOM or the budget refusal, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autod code=needs_signin
  fusion_dismiss_blocking_dialogs            PASS 
  fusion_open_cloud_file                     FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_show_schematic                      FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_show_2d_board                       FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_board_info                          FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'rawXml'
  fusion_open_electronics                    FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'isElectronics'
  fusion_list_text_commands                  FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'commands'
  fusion_execute_text_command                FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_show_3d_board                       FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_inspect_bodies                      FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'bodies'; missing field 'units'
  fusion_physical_properties                 FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_get_design_info                     FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_get_parameters                      FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_document_info                       FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_delete_cloud_file#guard             PASS 
  fusion_set_parameter#guard                 PASS 
  fusion_run_modeling_script#guard           FAIL - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)
  fusion_assembly_bom#guard                  FAIL - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)
  fusion_run_modeling_script                 FAIL - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  fusion_close_window#noargs                 PASS 
  fusion_cleanup_cloud_files#guard           PASS 
  fusion_screenshot_fusion                   PASS 
  fusion_state                               PASS 
  fusion_demo_progress#unknown               PASS 
  fusion_action_ledger                       PASS 
  fusion_addin_status                        FAIL - expected success, got error=The Adom add-in did not answer on port 8774. Fusion is running. code=addin_not_answering
  fusion_alerts                              PASS 
  fusion_verb_times                          PASS 
  fusion_live_feed                           PASS 
  fusion_prove_result                        PASS 
  fusion_set_driving_badge                   PASS 
  fusion_set_window_sizing                   PASS 
  fusion_cancel_run                          PASS 
  fusion_preflight_lbr                       PASS 
  fusion_library_parts                       PASS 
  fusion_routing_state#guard                 PASS 
  fusion_route_net#guard                     PASS 
  fusion_routing_drc#guard                   PASS 
  fusion_plan_route#guard                    PASS 
  fusion_schematic#guard                     PASS 
  fusion_schematic#missing                   PASS 
  fusion_make_showcase_project#guard         PASS 
  fusion_eagle_import_status#guard           PASS 
  fusion_show_attributes#guard               PASS 
  focus_invariance                           PASS
cleanup: Fusion was already running before the run - leaving it (user's session).

Section coverage (John's product map, 2026-08-14):
  gui-driving                            8 pass / 9 fail (21 manual, 0 skip)  RED
  cad-3d-bom                             8 pass / 7 fail (7 manual, 0 skip)  RED
  mcp-server                             1 pass / 0 fail (1 manual, 0 skip)  green
  python-addin                           0 pass / 6 fail (1 manual, 0 skip)  RED
  aps                                    9 pass / 0 fail (13 manual, 0 skip)  green
  auth-tokens                            3 pass / 0 fail (5 manual, 0 skip)  green
  exports                                0 pass / 0 fail (1 manual, 0 skip)  untested-this-tier
  bridge-lifecycle                       12 pass / 0 fail (15 manual, 0 skip)  green

45 PASS, 22 FAIL (80 manual-tier, 0 skipped) -> /home/adom/project/adom-desktop-fusion-bridge/tests/reports/verb-test-2026-10-07_1158.json
  FAIL: fusion_get_app_state - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_start - expected success, got error='fusion_start' did not respond within ab's 90s budget. code=timed_out
  FAIL: fusion_get_preferences - expected success, got error=Add-in request failed: http://127.0.0.1:8774/command: Connection Failed: Connect code=None; missing field 'current'
  FAIL: fusion_set_preference - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=None
  FAIL: fusion_assembly_bom - expected a BOM or the budget refusal, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autod code=needs_signin
  FAIL: fusion_open_cloud_file - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_show_schematic - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_show_2d_board - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_board_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'rawXml'
  FAIL: fusion_open_electronics - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'isElectronics'
  FAIL: fusion_list_text_commands - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'commands'
  FAIL: fusion_execute_text_command - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_show_3d_board - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_inspect_bodies - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'bodies'; missing field 'units'
  FAIL: fusion_physical_properties - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_get_design_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_get_parameters - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_document_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_run_modeling_script#guard - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)
  FAIL: fusion_assembly_bom#guard - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)
  FAIL: fusion_run_modeling_script - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin
  FAIL: fusion_addin_status - expected success, got error=The Adom add-in did not answer on port 8774. Fusion is running. code=addin_not_answering
{
  "discussion": {
    "id": 1728,
    "page_id": 13,
    "author_name": "John Lauer",
    "title": "Daily verb run RED 2026-10-07: 22 failing verb(s)",
    "body": "Automated daily verb run went red (2026-10-07, exit 1). Scorecard tail:\n\n```\n  bridge-lifecycle                       12 pass / 0 fail (15 manual, 0 skip)  green\n\n45 PASS, 22 FAIL (80 manual-tier, 0 skipped) -> /home/adom/project/adom-desktop-fusion-bridge/tests/reports/verb-test-2026-10-07_1158.json\n  FAIL: fusion_get_app_state - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_start - expected success, got error='fusion_start' did not respond within ab's 90s budget. code=timed_out\n  FAIL: fusion_get_preferences - expected success, got error=Add-in request failed: http://127.0.0.1:8774/command: Connection Failed: Connect code=None; missing field 'current'\n  FAIL: fusion_set_preference - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=None\n  FAIL: fusion_assembly_bom - expected a BOM or the budget refusal, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autod code=needs_signin\n  FAIL: fusion_open_cloud_file - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_show_schematic - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_show_2d_board - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_board_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'rawXml'\n  FAIL: fusion_open_electronics - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'isElectronics'\n  FAIL: fusion_list_text_commands - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'commands'\n  FAIL: fusion_execute_text_command - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_show_3d_board - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_inspect_bodies - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin; missing field 'bodies'; missing field 'units'\n  FAIL: fusion_physical_properties - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_get_design_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_get_parameters - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_document_info - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_run_modeling_script#guard - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)\n  FAIL: fusion_assembly_bom#guard - expected errorCode=wrong_document got needs_signin (error=Fusion is at the Autodesk sign-in screen (Signing in - Autod)\n  FAIL: fusion_run_modeling_script - expected success, got error=Fusion is at the Autodesk sign-in screen (Signing in - Autodesk Fusion ), so the code=needs_signin\n  FAIL: fusion_addin_status - expected success, got error=The Adom add-in did not answer on port 8774. Fusion is running. code=addin_not_answering\n```\n\nFull log: tests/reports/daily-cron-2026-10-07.log on the dev container. Versions at run time are in the readiness line of the log. Triage per dev-skills/fusion-verb-tests: re-run the failing verbs with --only first, a startup race or relay flake re-passes; a repeat failure is the real finding.\n",
    "category": "general",
    "is_pinned": 0,
    "is_locked": 0,
    "reply_count": 0,
    "last_reply_at": null,
    "created_at": "2026-10-07 11:58:38",
    "updated_at": "2026-10-07 11:58:38",
    "status": "open",
    "labels": "[]",
    "closed_at": null,
    "closed_by_name": null,
    "mentions_json": "[]",
    "number": 111,
    "deleted_at": null,
    "deleted_by_id": null,
    "deleted_by_name": null,
    "edited_at": null,
    "url": "https://wiki.adom.inc/adom/fusion-bridge/issues/111"
  },
  "page_discussion_count": 110
}
hint [WEB_URL]: https://wiki.adom.inc/adom/fusion-bridge/issues/111
hint [BODY_POSTED]: body posted (4203 chars): Automated daily verb run went red (2026-10-07, exit 1). Scorecard tail:  ```   bridge-lifecycle                       12 pass / 0 fail (15 manual, 0 skip)  gree...