1 file changed +18−15
page.json+18−15
@@ -38,31 +38,31 @@         "number": "2",         "name": "STAT",         "type": "output",-        "description": "Open drain charge status indicator. Connect to pull-up rail via 10-k\u03a9 resistor. LOW = charge in progress; HIGH = charge complete or disabled; blinks at 1Hz on fault. Can be disabled via STAT_DIS."+        "description": "Open drain charge status indicator. Connect to pull-up rail via 10-kΩ resistor. LOW = charge in progress; HIGH = charge complete or disabled; blinks at 1Hz on fault. Can be disabled via STAT_DIS."       },       {         "number": "3",         "name": "/CE",         "type": "input",-        "description": "Active low charge enable pin. Battery charging is enabled when EN_CHG bit = 1 and /CE pin is LOW. Internally pulled low with 900-k\u03a9 resistor."+        "description": "Active low charge enable pin. Battery charging is enabled when EN_CHG bit = 1 and /CE pin is LOW. Internally pulled low with 900-kΩ resistor."       },       {         "number": "4",         "name": "SDA",         "type": "bidirectional",-        "description": "I2C interface data. Connect SDA to the pull-up rail through a 10-k\u03a9 resistor."+        "description": "I2C interface data. Connect SDA to the pull-up rail through a 10-kΩ resistor."       },       {         "number": "5",         "name": "SCL",         "type": "input",-        "description": "I2C interface clock. Connect SCL to the pull-up rail through a 10-k\u03a9 resistor."+        "description": "I2C interface clock. Connect SCL to the pull-up rail through a 10-kΩ resistor."       },       {         "number": "6",         "name": "/INT",         "type": "output",-        "description": "Open drain active low interrupt output. Connect to pull-up rail via 10-k\u03a9 resistor. Sends 256-\u00b5s active-low pulse to the host to report charger status and fault events."+        "description": "Open drain active low interrupt output. Connect to pull-up rail via 10-kΩ resistor. Sends 256-µs active-low pulse to the host to report charger status and fault events."       },       {         "number": "7",@@ -80,7 +80,7 @@         "number": "9",         "name": "/PG",         "type": "output",-        "description": "Open drain active low power good indicator. Connect to pull-up rail via 10-k\u03a9 resistor. LOW indicates a good input source when input voltage is within VVBUS_OP (3.9V) and can provide more than IPOORSRC (30 mA)."+        "description": "Open drain active low power good indicator. Connect to pull-up rail via 10-kΩ resistor. LOW indicates a good input source when input voltage is within VVBUS_OP (3.9V) and can provide more than IPOORSRC (30 mA)."       },       {         "number": "10",@@ -92,7 +92,7 @@         "number": "11",         "name": "REGN",         "type": "power_out",-        "description": "Gate drive supply. Bias supply for internal MOSFET drivers and IC. Bypass REGN to GND with a 4.7-\u00b5F ceramic capacitor. REGN current limit is 50 mA."+        "description": "Gate drive supply. Bias supply for internal MOSFET drivers and IC. Bypass REGN to GND with a 4.7-µF ceramic capacitor. REGN current limit is 50 mA."       },       {         "number": "12",@@ -104,25 +104,25 @@         "number": "13",         "name": "BAT",         "type": "power_in",-        "description": "Battery power connection. Connect minimum recommended 10-\u00b5F capacitance (after derating) closely to BAT and GND."+        "description": "Battery power connection. Connect minimum recommended 10-µF capacitance (after derating) closely to BAT and GND."       },       {         "number": "14",         "name": "BAT",         "type": "power_in",-        "description": "Battery power connection. Connect minimum recommended 10-\u00b5F capacitance (after derating) closely to BAT and GND."+        "description": "Battery power connection. Connect minimum recommended 10-µF capacitance (after derating) closely to BAT and GND."       },       {         "number": "15",         "name": "SYS",         "type": "power_out",-        "description": "System connection. Internal BATFET connects SYS to BAT. When battery falls below minimum system voltage, the switch-mode converter keeps SYS above the minimum. Connect 2x22-\u00b5F capacitance (after derating) close to SYS and PGND."+        "description": "System connection. Internal BATFET connects SYS to BAT. When battery falls below minimum system voltage, the switch-mode converter keeps SYS above the minimum. Connect 2x22-µF capacitance (after derating) close to SYS and PGND."       },       {         "number": "16",         "name": "SYS",         "type": "power_out",-        "description": "System connection. Internal BATFET connects SYS to BAT. When battery falls below minimum system voltage, the switch-mode converter keeps SYS above the minimum. Connect 2x22-\u00b5F capacitance (after derating) close to SYS and PGND."+        "description": "System connection. Internal BATFET connects SYS to BAT. When battery falls below minimum system voltage, the switch-mode converter keeps SYS above the minimum. Connect 2x22-µF capacitance (after derating) close to SYS and PGND."       },       {         "number": "17",@@ -152,19 +152,19 @@         "number": "21",         "name": "PMID",         "type": "power_in",-        "description": "Blocking MOSFET connection. Total low-ESR capacitance on VBUS and PMID (after derating) is 10 \u00b5F; at least 1-\u00b5F at VBUS with remainder (typically 10 \u00b5F) at PMID."+        "description": "Blocking MOSFET connection. Total low-ESR capacitance on VBUS and PMID (after derating) is 10 µF; at least 1-µF at VBUS with remainder (typically 10 µF) at PMID."       },       {         "number": "22",         "name": "PMID",         "type": "power_in",-        "description": "Blocking MOSFET connection. Total low-ESR capacitance on VBUS and PMID (after derating) is 10 \u00b5F; at least 1-\u00b5F at VBUS with remainder (typically 10 \u00b5F) at PMID."+        "description": "Blocking MOSFET connection. Total low-ESR capacitance on VBUS and PMID (after derating) is 10 µF; at least 1-µF at VBUS with remainder (typically 10 µF) at PMID."       },       {         "number": "23",         "name": "VBUS",         "type": "power_in",-        "description": "Input supply. VBUS is connected to the external DC supply (3.9-6.2 V operating). Bypass VBUS to GND with at least 1-\u00b5F ceramic capacitor placed close to the IC."+        "description": "Input supply. VBUS is connected to the external DC supply (3.9-6.2 V operating). Bypass VBUS to GND with at least 1-µF ceramic capacitor placed close to the IC."       },       {         "number": "24",@@ -234,5 +234,8 @@     "docs/bq25883rger-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file