  "component": {
    "mpn": "BG120-06-A-0-N-D",
    "manufacturer": "Global Connector Technology",
    "package": "PinSocket_2x03_P2.54mm_Vertical_SMD",
    "pin_count": 6,
    "category": "Connectors",
    "subcategory": "Female Headers",
    "datasheet": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8590907997264551936",
    "parts": {
      "symbol": "bg120-06-a-0-n-d.kicad_sym",
      "footprint": "bg120-06-a-0-n-d.kicad_mod",
      "model_3d": "bg120-06-a-0-n-d-hero.glb",
      "model_3d_step": "bg120-06-a-0-n-d.step",
      "lbr": "bg120-06-a-0-n-d.lbr",
      "model_3d_plain": "bg120-06-a-0-n-d.glb"
    },
    "distributor_links": {
      "lcsc": "C5596298",
      "digikey": "2073-BG120-06-A-0-N-D-ND"
    },
    "distributor_check": {
      "checked_at": "2026-11-07T02:29:12Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": "2073-BG120-06-A-0-N-D-ND",
        "status": "found",
        "lifecycle": "Active"
      },
      "mouser": {
        "pn": null,
        "status": "no match"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "1",
        "type": "passive",
        "description": "Contact 1; numbering follows the footprint."
      },
      {
        "number": "2",
        "name": "2",
        "type": "passive",
        "description": "Contact 2; numbering follows the footprint."
      },
      {
        "number": "3",
        "name": "3",
        "type": "passive",
        "description": "Contact 3; numbering follows the footprint."
      },
      {
        "number": "4",
        "name": "4",
        "type": "passive",
        "description": "Contact 4; numbering follows the footprint."
      },
      {
        "number": "5",
        "name": "5",
        "type": "passive",
        "description": "Contact 5; numbering follows the footprint."
      },
      {
        "number": "6",
        "name": "6",
        "type": "passive",
        "description": "Contact 6; numbering follows the footprint."
      }
    ],
    "provenance": {
      "extractor": "extract_pins",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins",
        "primary_model": "connector numbering",
        "primary_mode": "convention",
        "consensus_model": null,
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "vision extraction: provenance cannot be text-verified; needs consensus"
        ],
        "pages_sent": null,
        "cost_usd": 0,
        "at": "2026-11-07T02:29:07"
      },
      "datasheet": {
        "url": "https://jlcpcb.com/api/file/downloadByFileSystemAccessId/8590907997264551936",
        "pages": 7,
        "sha256": "",
        "source_tier": "lcsc"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 6,
        "described": 6,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "bg120-06-a-0-n-d.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          6.8,
          7.62,
          7.45
        ],
        "zmin_mm": 0.02,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "20e12d209b9b2fe0eb0079edb6cdaf4fad5f833a8b3f4d42b009119d6af5939a",
        "checked": "2026-11-07",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  },
  "metadata": {
    "specs": {
      "Manufacturer": "Global Connector Technology",
      "Package": "PinSocket_2x03_P2.54mm_Vertical_SMD",
      "Category": "Connectors",
      "Pins": "6"
    },
    "appearance": {
      "contacts": {
        "quote": "3.2.1 Contacts Phosphor Bronze, or other equivalent copper alloys.",
        "page": 1,
        "doc": "ds.pdf",
        "material": "Phosphor Bronze"
      },
      "version": 1,
      "datasheet_sha256": ""
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "",
      "rows": [
        {
          "name": "Insertion force",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "N / Pin",
          "min": null,
          "typ": null,
          "max": 3,
          "conditions": "Per EIA-364-13B (Receptacle / Plug)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Unmating force",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "N / Pin",
          "min": 0.3,
          "typ": null,
          "max": null,
          "conditions": "Initial, per EIA-364-13B (Receptacle / Plug)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Contact retention force",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "N / Pin",
          "min": 5,
          "typ": null,
          "max": null,
          "conditions": "Post pushed perpendicular to base housing at 25 mm/minute",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Durability contact resistance",
          "symbol": "",
          "kind": "electrical",
          "unit": "mΩ",
          "min": null,
          "typ": null,
          "max": 30,
          "conditions": "After 100 mating cycles at 25.4 mm/minute, per EIA-364-09C",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Current rating",
          "symbol": "",
          "kind": "absolute_maximum",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 3,
          "conditions": "Per EIA-364-70, based on 30°C rise over ambient",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Voltage rating",
          "symbol": "",
          "kind": "absolute_maximum",
          "unit": "V AC / DC",
          "min": null,
          "typ": null,
          "max": 250,
          "conditions": "Per EIA-364-20B",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Low level circuit resistance (initial)",
          "symbol": "",
          "kind": "electrical",
          "unit": "mΩ",
          "min": null,
          "typ": null,
          "max": 20,
          "conditions": "Per EIA-364-23B; current 100 mA max; max open circuit voltage 20 mV DC",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Low level circuit resistance (after environmental test)",
          "symbol": "",
          "kind": "electrical",
          "unit": "mΩ",
          "min": null,
          "typ": null,
          "max": 30,
          "conditions": "After environmental test, per EIA-364-23B; current 100 mA max; max open circuit voltage 20 mV DC",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Insulation resistance (before conditioning)",
          "symbol": "",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 1000,
          "typ": null,
          "max": null,
          "conditions": "500 V DC / 1 min, per EIA-364-21C, between 10 adjacent and 10 opposing contacts",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Insulation resistance (after conditioning)",
          "symbol": "",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 500,
          "typ": null,
          "max": null,
          "conditions": "500 V DC / 1 min, per EIA-364-21C, between 10 adjacent and 10 opposing contacts",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Capacitance between adjacent unmated contacts",
          "symbol": "",
          "kind": "electrical",
          "unit": "pF",
          "min": null,
          "typ": null,
          "max": 2,
          "conditions": "At 1 kHz",
          "source_page": 3,
          "source": "datasheet"
        },
        {
          "name": "Operating temperature range",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": -40,
          "typ": null,
          "max": 105,
          "conditions": "",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Thermal shock circuit resistance",
          "symbol": "",
          "kind": "electrical",
          "unit": "mΩ",
          "min": null,
          "typ": null,
          "max": 30,
          "conditions": "Initial and after test, per EIA-364-32C, test condition a, b (-40°C/30 min to +105°C/30 min, 5 cycles)",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Humidity test insulation resistance",
          "symbol": "",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 500,
          "typ": null,
          "max": null,
          "conditions": "After humidity test: 40°C, 90-95% RH, 96 hrs, per EIA-364-31B",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Humidity test dielectric withstanding voltage",
          "symbol": "",
          "kind": "electrical",
          "unit": "V AC",
          "min": 600,
          "typ": null,
          "max": null,
          "conditions": "For 1 minute, after humidity test, per EIA-364-31B",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Salt spray insulation resistance",
          "symbol": "",
          "kind": "electrical",
          "unit": "MΩ",
          "min": 500,
          "typ": null,
          "max": null,
          "conditions": "After salt spray: 35±2°C, 16 hrs, 5% NaCl, per EIA-364-26B",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Salt spray dielectric withstanding voltage",
          "symbol": "",
          "kind": "electrical",
          "unit": "V AC",
          "min": 600,
          "typ": null,
          "max": null,
          "conditions": "For 1 minute, after salt spray, per EIA-364-26B",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Solder coverage (solderability)",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "%",
          "min": 95,
          "typ": null,
          "max": null,
          "conditions": "Per EIA-364-71B, 245±3°C, 3-5 sec dwell",
          "source_page": 5,
          "source": "datasheet"
        },
        {
          "name": "Resistance to soldering heat (minimum temperature)",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "°C",
          "min": 210,
          "typ": null,
          "max": null,
          "conditions": "For 30 seconds max; pre-heat 100-150°C for 60 seconds max; peak 260±5°C, 10±5 sec",
          "source_page": 5,
          "source": "datasheet"
        }
      ]
    }
  },
  "variants": [],
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "bg120-06-a-0-n-d"
  ],
  "discovery_pitch": "BG120-06-A-0-N-D (Global Connector Technology) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "author": {
    "name": "Ray",
    "email": "[email protected]"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "bg120-06-a-0-n-d.kicad_sym",
    "bg120-06-a-0-n-d.kicad_mod",
    "bg120-06-a-0-n-d.glb",
    "bg120-06-a-0-n-d.step",
    "bg120-06-a-0-n-d.lbr",
    "docs/hero.png",
    "docs/bg120-06-a-0-n-d-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "bg120-06-a-0-n-d-hero.glb",
    "bg120-06-a-0-n-d-hero.overlay.json"
  ],
  "visibility": {
    "public": true
  }
}