← Commit history

asdm20p13s-r: specified limits as data (metadata.characteristics, 27 rows from the datasheet)

Ray ·c9d601caa3 ·19d ago ·parent a42d0f6
2 files changed +366−1
README.md+34
@@ -26,6 +26,40 @@ ASDM20P13S-R from ASDsemi, in a SOP-8. Pinout and pin descriptions extracted fro | Category | Transistors/Thyristors | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-Source Breakdown Voltage | BVDSS | -20 |  |  | V | VGS =0V, ID =-250uA | 2 |+| Gate Threshold Voltage | VGS(TH) | -0.3 | -0.6 | -1 | V | VGS =VDS, ID =-250uA | 2 |+| Drain-Source Leakage Current | IDSS |  |  | -1 | uA | VDS=-20V, VGS =0V | 2 |+| Gate-Source Leakage Current | IGSS | -100 |  | 100 | nA | VGS=±12V, VDS =0V | 2 |+| Static Drain-source On-Resistance | RDS(ON) |  | 6 | 13 | mΩ | VGS=-10V, ID=-8A | 2 |+| Static Drain-source On-Resistance | RDS(ON) |  | 7.7 | 16 | mΩ | VGS=-4.5V, ID=-6A | 2 |+| Forward Transconductance | gFS |  | 9 |  | s | VDS =-10V, ID=-5A | 2 |+| Source-drain voltage | VSD |  |  | 1.28 | V | Is=-9A | 2 |+| Input capacitance | Ciss |  | 2160 |  | pF | f = 1MHz | 2 |+| Output capacitance | Coss |  | 432 |  | pF |  | 2 |+| Reverse transfer capacitance | Crss |  | 288 |  | pF |  | 2 |+| Total gate charge | Qg |  | 15 |  | nC | VDD =25V, ID = 8A, VGS = 10V | 2 |+| Gate - Source charge | Qgs |  | 4 |  | nC |  | 2 |+| Gate - Drain charge | Qgd |  | 6 |  | nC |  | 2 |+| Drain-Source Voltage | VDS |  |  | -20 | V |  | 1 |+| Gate-Source Voltage | VGS | -12 |  | 12 | V |  | 1 |+| Continuous Drain Current | ID |  |  | -13 | A | TC=25℃ | 1 |+| Continuous Drain Current | ID |  |  | -8.36 | A | TC=75℃ | 1 |+| Continuous Drain Current | ID |  |  | -6.93 | A | TC=100℃ | 1 |+| Pulsed Drain Current | IDM |  |  | -52 | A |  | 1 |+| Total Power Dissipation | PD |  |  | 3.6 | W | TC=25℃ | 1 |+| Total Power Dissipation | PD |  |  | 0.69 | W | TA=25℃ | 1 |+| Operating Junction Temperature | TJ | -55 |  | 150 | ℃ |  | 1 |+| Storage Temperature | TSTG | -55 |  | 150 | ℃ |  | 1 |+| Single Pulse Avalanche Energy | EAS |  |  | 80 | mJ |  | 1 |+| Thermal resistance, junction - case | RthJC |  |  | 24 | °C/W |  | 1 |+| Thermal resistance, junction - ambient | RthJA |  |  | 85 | °C/W |  | 1 |+ ## CAD (KiCad official)  - Symbol: `ASDM20P13S-R`
page.json+332−1
@@ -178,6 +178,337 @@       "Package": "SOP-8",       "Category": "Transistors/Thyristors",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "d117d93bcb65a2c0",+      "rows": [+        {+          "name": "Drain-Source Breakdown Voltage",+          "symbol": "BVDSS",+          "kind": "electrical",+          "unit": "V",+          "min": -20,+          "typ": null,+          "max": null,+          "conditions": "VGS =0V, ID =-250uA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Threshold Voltage",+          "symbol": "VGS(TH)",+          "kind": "electrical",+          "unit": "V",+          "min": -0.3,+          "typ": -0.6,+          "max": -1,+          "conditions": "VGS =VDS, ID =-250uA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source Leakage Current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "uA",+          "min": null,+          "typ": null,+          "max": -1,+          "conditions": "VDS=-20V, VGS =0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-Source Leakage Current",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": -100,+          "typ": null,+          "max": 100,+          "conditions": "VGS=±12V, VDS =0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-source On-Resistance",+          "symbol": "RDS(ON)",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 6,+          "max": 13,+          "conditions": "VGS=-10V, ID=-8A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-source On-Resistance",+          "symbol": "RDS(ON)",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 7.7,+          "max": 16,+          "conditions": "VGS=-4.5V, ID=-6A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Forward Transconductance",+          "symbol": "gFS",+          "kind": "electrical",+          "unit": "s",+          "min": null,+          "typ": 9,+          "max": null,+          "conditions": "VDS =-10V, ID=-5A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Source-drain voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.28,+          "conditions": "Is=-9A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 2160,+          "max": null,+          "conditions": "f = 1MHz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 432,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse transfer capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 288,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total gate charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 15,+          "max": null,+          "conditions": "VDD =25V, ID = 8A, VGS = 10V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate - Source charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 4,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate - Drain charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 6,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-Source Voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": -20,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Gate-Source Voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -12,+          "typ": null,+          "max": 12,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -13,+          "conditions": "TC=25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -8.36,+          "conditions": "TC=75℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current",+          "symbol": "ID",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -6.93,+          "conditions": "TC=100℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Drain Current",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": -52,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Total Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 3.6,+          "conditions": "TC=25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Total Power Dissipation",+          "symbol": "PD",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.69,+          "conditions": "TA=25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Operating Junction Temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "℃",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Storage Temperature",+          "symbol": "TSTG",+          "kind": "absolute_maximum",+          "unit": "℃",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Single Pulse Avalanche Energy",+          "symbol": "EAS",+          "kind": "absolute_maximum",+          "unit": "mJ",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance, junction - case",+          "symbol": "RthJC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 24,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Thermal resistance, junction - ambient",+          "symbol": "RthJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -219,4 +550,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}