page.json+11−8
@@ -38,43 +38,43 @@         "number": "2",         "name": "IN",         "type": "power_in",-        "description": "Voltage input pin. Supplies both switch channels; operating range 2.7 V to 5.5 V (abs max 6.5 V). Bypass with 0.1 \u00b5F and bulk 10 \u00b5F near pin."+        "description": "Voltage input pin. Supplies both switch channels; operating range 2.7 V to 5.5 V (abs max 6.5 V). Bypass with 0.1 µF and bulk 10 µF near pin."       },       {         "number": "3",         "name": "EN1",         "type": "input",-        "description": "Switch 1 enable input. Active high on AP2172 (this variant). VIL \u2264 0.8 V, VIH \u2265 2 V. Input leakage \u2264 1 \u00b5A."+        "description": "Switch 1 enable input. Active high on AP2172 (this variant). VIL ≤ 0.8 V, VIH ≥ 2 V. Input leakage ≤ 1 µA."       },       {         "number": "4",         "name": "EN2",         "type": "input",-        "description": "Switch 2 enable input. Active high on AP2172 (this variant). VIL \u2264 0.8 V, VIH \u2265 2 V. Input leakage \u2264 1 \u00b5A."+        "description": "Switch 2 enable input. Active high on AP2172 (this variant). VIL ≤ 0.8 V, VIH ≥ 2 V. Input leakage ≤ 1 µA."       },       {         "number": "5",         "name": "FLG2",         "type": "output",-        "description": "Switch 2 over-current and over-temperature fault report. Open-drain output, active low when triggered. Requires external pull-up (typ. 10 k\u03a9). 7 ms typical blanking time. IFLG = 10 mA max, RFLG \u2248 30 \u03a9 typ."+        "description": "Switch 2 over-current and over-temperature fault report. Open-drain output, active low when triggered. Requires external pull-up (typ. 10 kΩ). 7 ms typical blanking time. IFLG = 10 mA max, RFLG ≈ 30 Ω typ."       },       {         "number": "6",         "name": "OUT2",         "type": "power_out",-        "description": "Switch 2 voltage output. Delivers up to 1.0 A continuous (1.5 A typ current limit). Bypass with 0.1 \u00b5F plus bulk 68 \u00b5F at load per USB requirements."+        "description": "Switch 2 voltage output. Delivers up to 1.0 A continuous (1.5 A typ current limit). Bypass with 0.1 µF plus bulk 68 µF at load per USB requirements."       },       {         "number": "7",         "name": "OUT1",         "type": "power_out",-        "description": "Switch 1 voltage output. Delivers up to 1.0 A continuous (1.5 A typ current limit). Bypass with 0.1 \u00b5F plus bulk 68 \u00b5F at load per USB requirements."+        "description": "Switch 1 voltage output. Delivers up to 1.0 A continuous (1.5 A typ current limit). Bypass with 0.1 µF plus bulk 68 µF at load per USB requirements."       },       {         "number": "8",         "name": "FLG1",         "type": "output",-        "description": "Switch 1 over-current and over-temperature fault report. Open-drain output, active low when triggered. Requires external pull-up (typ. 10 k\u03a9). 7 ms typical blanking time. IFLG = 10 mA max, RFLG \u2248 30 \u03a9 typ."+        "description": "Switch 1 over-current and over-temperature fault report. Open-drain output, active low when triggered. Requires external pull-up (typ. 10 kΩ). 7 ms typical blanking time. IFLG = 10 mA max, RFLG ≈ 30 Ω typ."       }     ],     "provenance": {@@ -148,5 +148,8 @@     "docs/ap2172sg-13-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file