main
Ray Publish 0.1.0 529333b
{
  "slug": "aem10941-qfn",
  "version": "0.1.0",
  "type": "component",
  "description": "e-peas Power Management Specialized - PMIC. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
  "tags": [
    "component",
    "power management specialized - pmic",
    "aem10941-qfn",
    "factory-2.0.0",
    "extractor-text"
  ],
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "aem10941-qfn.kicad_sym",
    "aem10941-qfn.kicad_mod",
    "aem10941-qfn.glb",
    "aem10941-qfn.step",
    "aem10941-qfn.lbr",
    "docs/hero.png",
    "docs/aem10941-qfn-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "aem10941-qfn-hero.glb",
    "aem10941-qfn-hero.overlay.json"
  ],
  "component": {
    "mpn": "AEM10941-QFN",
    "manufacturer": "e-peas",
    "package": "Unknown",
    "pin_count": 29,
    "category": "Power Management Specialized - PMIC",
    "subcategory": "Power Management Specialized - PMIC",
    "datasheet": "https://www.mouser.com/datasheet/3/3770/1/DS_AEM10941.pdf",
    "parts": {
      "symbol": "aem10941-qfn.kicad_sym",
      "footprint": "aem10941-qfn.kicad_mod",
      "model_3d": "aem10941-qfn-hero.glb",
      "model_3d_plain": "aem10941-qfn.glb",
      "model_3d_step": "aem10941-qfn-etched.step",
      "model_3d_step_plain": "aem10941-qfn.step",
      "lbr": "aem10941-qfn.lbr"
    },
    "distributor_links": {
      "mouser": "120-AEM10941-QFN"
    },
    "distributor_check": {
      "checked_at": "2026-11-24T17:45:01Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": null,
        "status": "no match"
      },
      "mouser": {
        "pn": "120-AEM10941-QFN",
        "status": "found"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "BOOST",
        "type": "power_out",
        "description": "Output of the boost converter."
      },
      {
        "number": "2",
        "name": "SWBUCK",
        "type": "passive",
        "description": "Switching node of the buck converter."
      },
      {
        "number": "3",
        "name": "BUCK",
        "type": "power_out",
        "description": "Output of the buck converter."
      },
      {
        "number": "4",
        "name": "CFG[2]",
        "type": "input",
        "description": "Configuration input (logic low GND, high BUCK) used with CFG[1:0] to set the storage element protection thresholds and the LDO output voltages."
      },
      {
        "number": "5",
        "name": "CFG[1]",
        "type": "input",
        "description": "Configuration input (logic low GND, high BUCK) used with CFG[2] and CFG[0] to set the storage element protection thresholds and the LDO output voltages."
      },
      {
        "number": "6",
        "name": "CFG[0]",
        "type": "input",
        "description": "Configuration input (logic low GND, high BUCK) used with CFG[2:1] to set the storage element protection thresholds and the LDO output voltages."
      },
      {
        "number": "7",
        "name": "SELMPP[1]",
        "type": "input",
        "description": "Configuration input (logic low GND, high BUCK) used with SELMPP[0] to set the MPPT ratio."
      },
      {
        "number": "8",
        "name": "SELMPP[0]",
        "type": "input",
        "description": "Configuration input (logic low GND, high BUCK) used with SELMPP[1] to set the MPPT ratio."
      },
      {
        "number": "9",
        "name": "FB_PRIM_D",
        "type": "input",
        "description": "Analog pin used to configure the primary battery overdischarge voltage (optional); must be connected to GND if not used."
      },
      {
        "number": "10",
        "name": "FB_PRIM_U",
        "type": "input",
        "description": "Analog pin used to configure the primary battery overdischarge voltage (optional); must be connected to GND if not used."
      },
      {
        "number": "11",
        "name": "LVOUT",
        "type": "power_out",
        "description": "Output of the low voltage LDO regulator."
      },
      {
        "number": "12",
        "name": "ENHV",
        "type": "input",
        "description": "Enabling pin for the high-voltage LDO, logic low GND and logic high BUCK."
      },
      {
        "number": "13",
        "name": "FB_HV",
        "type": "input",
        "description": "Analog pin used to configure the high-voltage LDO when in custom mode (optional); must be left floating if not used."
      },
      {
        "number": "14",
        "name": "HVOUT",
        "type": "power_out",
        "description": "Output of the high voltage LDO regulator."
      },
      {
        "number": "15",
        "name": "BAL",
        "type": "passive",
        "description": "Connection to the mid-point of a dual-cell supercapacitor (optional); must be connected to GND if not used."
      },
      {
        "number": "16",
        "name": "BATT",
        "type": "bidirectional",
        "description": "Connection to the energy storage element, battery or capacitor; cannot be left floating."
      },
      {
        "number": "17",
        "name": "PRIM",
        "type": "power_in",
        "description": "Connection to the primary battery (optional); must be connected to GND if not used."
      },
      {
        "number": "18",
        "name": "ENLV",
        "type": "input",
        "description": "Enabling pin for the low-voltage LDO, logic low GND and logic high any voltage between BUCK and BOOST."
      },
      {
        "number": "19",
        "name": "STATUS[2]",
        "type": "output",
        "description": "Logic output (low GND, high BATT) asserted when the AEM performs a MPP evaluation."
      },
      {
        "number": "20",
        "name": "STATUS[1]",
        "type": "output",
        "description": "Logic output (low GND, high BATT) that is HIGH during TCRIT when in SHUTDOWN MODE and as long as in PRIMARY BATTERY MODE, LOW otherwise."
      },
      {
        "number": "21",
        "name": "STATUS[0]",
        "type": "output",
        "description": "Logic output (low GND, high BATT) asserted when the LDOs can be enabled."
      },
      {
        "number": "22",
        "name": "SET_OVCH",
        "type": "input",
        "description": "Analog pin used to configure the storage element protection thresholds when in custom mode (optional); must be connected to BUCK if not used."
      },
      {
        "number": "23",
        "name": "SET_CHRDY",
        "type": "input",
        "description": "Analog pin used to configure the storage element protection thresholds when in custom mode (optional); must be connected to BUCK if not used."
      },
      {
        "number": "24",
        "name": "SET_OVDIS",
        "type": "input",
        "description": "Analog pin used to configure the storage element protection thresholds when in custom mode (optional); must be connected to BUCK if not used."
      },
      {
        "number": "25",
        "name": "SRC",
        "type": "power_in",
        "description": "Connection to the harvested energy source (shared with pin 26)."
      },
      {
        "number": "26",
        "name": "SRC",
        "type": "power_in",
        "description": "Connection to the harvested energy source (shared with pin 25)."
      },
      {
        "number": "27",
        "name": "BUFSRC",
        "type": "passive",
        "description": "Connection to an external capacitor buffering the boost converter input."
      },
      {
        "number": "28",
        "name": "SWBOOST",
        "type": "passive",
        "description": "Switching node of the boost converter."
      },
      {
        "number": "29",
        "name": "GND",
        "type": "power_in",
        "description": "Exposed pad ground connection, must be strongly tied to the PCB ground plane."
      }
    ],
    "provenance": {
      "extractor": "extract_pins 0.3",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins 0.3",
        "primary_model": "claude-haiku-5-5",
        "primary_mode": "text",
        "consensus_model": "claude-sonnet-5-5",
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "no package hint was available; multi-package datasheets are a coin flip without one",
          "extractor flagged: Exposed pad (GND, thermal pad) is not numbered 1..28 in Table 2; it appears only as PAD29 in the sch",
          "exposed pad 29 added from the footprint"
        ],
        "pages_sent": 15,
        "cost_usd": 0.0566,
        "at": "2026-11-24T17:46:09"
      },
      "datasheet": {
        "url": "https://www.mouser.com/datasheet/3/3770/1/DS_AEM10941.pdf",
        "pages": 52,
        "sha256": "4a2f76474c84fa3b",
        "source_tier": "lcsc",
        "citation": "e-peas datasheet, copy hosted by Mouser"
      },
      "cad": "Adom_Gen derived land; symbol and 3D generated",
      "pins": {
        "total": 29,
        "described": 29,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "aem10941-qfn.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          5.02,
          5.02,
          0.75
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "93a6e176be0b63f314dfa2975ec4fcfb7b32eb10bc31007aedacc69fe264366c",
        "checked": "2026-11-24",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      },
      {
        "file": "aem10941-qfn-etched.step",
        "role": "eda",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          5.02,
          5.02,
          0.75
        ],
        "zmin_mm": 0.0,
        "centre_offset_mm": 0.0,
        "footprint_binding": "identity",
        "sha256": "a4965b1a15ee67f1b71823eaa17ee21ef8910c6f200a9d90863e580e2b7c4be2",
        "checked": "2026-11-24",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ]
  }
}