Adom Fields: where the current and the heat go on your board.
terminals: a pad number on two coincident lands cannot be named with at (Texas DGN0008B exposed pad)
Version: adom-fields 0.10.5.
What happens. KiCad's stock footprint Package_SO:Texas_DGN0008B_VSSOP-8-1EP_3x3mm_P0.65mm_EP2x3mm_Mask1.88x1.98mm_ThermalVias has pad "9" eight times. Two of them are SMD pads at the footprint centre: 2 x 3 mm copper, plus a 1.6 x 2.94 mm one. The other six are 0.5 mm via pads. Listing that pad in loads.GND.terminals, with at set to the centre, is refused: ERROR: GND: U101.9 must identify exactly one pad on this net. No coordinate can name one of two coincident lands.
Expected. Two pads with the same number at the same at should be treated as one land, since they are one piece of copper (KiCad unions them). Or at could match the larger of them. AI Flow asks for a complete terminal list per loaded net, so a footprint like this forces the user to leave the pad out (it carried 0 A here, so it is harmless, but it has to be explained in a spec amendment).
Seen on adom/am32-esc-v1 (U101, TPS7A4101DGNR).