00:00:00.000 --> 00:00:03.692
We corrected an oversized heat contact in the earlier model.
00:00:03.692 --> 00:00:08.122
The smaller assumed contact shows heat spreading from Q1 into the heatsink.
00:00:08.122 --> 00:00:10.707
Weak convection leaves the case too hot.
00:00:10.707 --> 00:00:15.506
Stronger assumed convection lowers the temperature, but this is not measured fan performance.
00:00:15.506 --> 00:00:17.352
The thermal gate stays open.