main
John Lauer
Publish 4 minute R10-to-R11 progression film with player captions
80d34ca
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291
WEBVTT
00:00:00.060 --> 00:00:04.141
We're building a digitally controlled
electronic load with Adom AI Flow.
00:00:04.621 --> 00:00:07.541
A side-mounted fan and a heatsink handle
the heat while
00:00:07.541 --> 00:00:09.041
keeping test points accessible.
00:00:09.741 --> 00:00:13.401
Follow the real sourcing, circuit, layout
and probing iterations
00:00:13.401 --> 00:00:14.841
that shaped this prototype.
00:00:15.328 --> 00:00:19.888
AI Flow opens its dashboard automatically,
keeping the design stages visible.
00:00:20.067 --> 00:00:21.881
Mouser blocks this browser request.
00:00:22.432 --> 00:00:24.332
The native browser reaches the same fan.
00:00:24.747 --> 00:00:27.787
Its product page also links to
manufacturer CAD.
00:00:27.895 --> 00:00:31.415
KiCad moves three capacitors to correct
the placement collisions.
00:00:32.100 --> 00:00:34.000
The top ground pour appears in KiCad.
00:00:34.127 --> 00:00:38.187
A parallel shunt via and bottom connection
strengthen this current path.
00:00:38.707 --> 00:00:40.100
Analysis still comes next.
00:00:40.266 --> 00:00:42.766
Nine checked vias are added around the
rectifier.
00:00:43.386 --> 00:00:47.166
This accelerated view shows the geometry
change; cooling performance
00:00:47.166 --> 00:00:48.786
needs its own analysis.
00:00:48.940 --> 00:00:53.260
Simulated tach feedback disappears, and
the controller latches off.
00:00:53.840 --> 00:00:54.920
This is a software replay.
00:00:55.382 --> 00:00:58.302
The corrected current model exposes three
failing paths.
00:00:58.302 --> 00:01:02.602
We inspect where the current concentrates
before accepting any layout.
00:01:03.122 --> 00:01:06.333
This is a diagnostic candidate, with the
thermal gate still open.
00:01:06.393 --> 00:01:09.918
This iteration compares the bottom copper
and assumed airflow.
00:01:10.678 --> 00:01:13.098
The rectifier still exceeds its still air
budget.
00:01:13.678 --> 00:01:16.518
A better looking heat map is not enough;
the numerical
00:01:16.518 --> 00:01:17.867
limit must pass too.
00:01:17.893 --> 00:01:21.978
These three main current paths now fall
below the screening limit.
00:01:22.438 --> 00:01:23.967
Full board acceptance is still pending.
00:01:24.501 --> 00:01:26.761
The rectifier passes its still air screen.
00:01:27.301 --> 00:01:28.800
Transistor cooling remains open.
00:01:29.228 --> 00:01:32.833
The rectifier model distinguishes its
cathode plate and two anodes.
00:01:32.893 --> 00:01:37.341
The new rectifier is checked on the native
board, including its underside.
00:01:37.821 --> 00:01:39.200
Cooling hardware is not fitted yet.
00:01:39.843 --> 00:01:42.863
The dashboard advances from current
analysis to thermal.
00:01:43.443 --> 00:01:46.267
That progress leaves the unresolved
cooling gate visible.
00:01:46.514 --> 00:01:49.234
Two layer manufacturing outputs get a
review.
00:01:49.754 --> 00:01:51.633
This package is not released for
fabrication.
00:01:52.180 --> 00:01:55.200
KiCad highlights each complete power net
for inspection.
00:01:55.980 --> 00:01:59.340
This accelerated tour checks the saved
routing; it does not
00:01:59.340 --> 00:02:00.300
show the routes being created.
00:02:00.565 --> 00:02:04.545
This labeled replay shows the solver
placing candidate text.
00:02:05.145 --> 00:02:06.100
It is not a live KiCad edit.
00:02:06.679 --> 00:02:08.933
The saved reference labels get a native
visual check.
00:02:09.494 --> 00:02:12.174
KiCad adds the labels and contact frames.
00:02:12.894 --> 00:02:13.667
The copper stays unchanged.
00:02:14.253 --> 00:02:16.033
Opaque ink makes the labels readable.
00:02:16.344 --> 00:02:18.533
Both faces now identify the contacts.
00:02:18.896 --> 00:02:21.567
One dashboard updates live, without
reloading.
00:02:21.905 --> 00:02:24.067
We inspect the revised component geometry.
00:02:24.959 --> 00:02:26.400
Every chip carries a readable identity.
00:02:26.820 --> 00:02:30.840
In this software test, the temperature
allowance triggers shutdown.
00:02:31.540 --> 00:02:33.033
Cooling back down does not restart the
load.
00:02:33.033 --> 00:02:36.064
The compact revision is 72 millimeters square.
00:02:36.469 --> 00:02:38.650
Large corner pins stay on the scaffold grid,
00:02:38.964 --> 00:02:40.806
and USB-C sits at the edge.
00:02:41.211 --> 00:02:44.538
The four-wire fan connector and its control circuit
are now routed.
00:02:44.943 --> 00:02:46.348
This is a geometry review;
00:02:46.736 --> 00:02:48.528
cooling qualification is still open.
00:02:48.633 --> 00:02:52.606
The new fan has separate speed feedback
and PWM control wires.
00:02:53.051 --> 00:02:57.224
Its digital twin keeps the housing and wires fixed
while the rotor turns.
00:02:57.678 --> 00:03:00.344
The simulated cycle gently varies the speed
00:03:00.626 --> 00:03:01.686
and returns to rest.
00:03:02.141 --> 00:03:04.068
The animation runs in slow motion;
00:03:04.394 --> 00:03:06.764
measured cooling still needs an actual test.
00:03:06.873 --> 00:03:09.473
The thermal model needs the complete heat path:
00:03:09.903 --> 00:03:12.523
from Q1, through its insulating interface,
00:03:12.783 --> 00:03:14.823
into the heatsink, and out to the air.
00:03:15.263 --> 00:03:18.493
This comparison uses explicit cooling assumptions.
00:03:18.933 --> 00:03:20.863
It shows why fan failure matters,
00:03:21.143 --> 00:03:24.883
but it does not qualify the assembly
or increase our five-watt rating.
00:03:25.006 --> 00:03:26.806
The bare board cleared the probes,
00:03:27.076 --> 00:03:28.966
but adding the cooler exposed a bug:
00:03:29.276 --> 00:03:31.296
the checker was skipping large objects.
00:03:31.726 --> 00:03:35.896
After fixing it, the replay found real collisions
and wire snags.
00:03:36.326 --> 00:03:38.566
That sends this design back to placement,
00:03:38.926 --> 00:03:43.446
where we move the probe ground and the five-volt
test point into the access corridor.
00:03:43.573 --> 00:03:45.784
We turned the fan toward the side of the board,
00:03:46.147 --> 00:03:48.648
and rotated the molecule to suit the probe head.
00:03:49.062 --> 00:03:51.961
A new ground contact position keeps the tether clear.
00:03:52.405 --> 00:03:55.010
The revised board passes native rule checks,
00:03:55.338 --> 00:03:57.960
and the replay clears these cooling envelopes.
00:03:58.401 --> 00:04:01.743
The mounting hardware and fan harness
still need their own review.
00:04:02.031 --> 00:04:04.932
These are calculated current densities
on the revised copper.
00:04:05.361 --> 00:04:07.033
All six networks pass the screen.
00:04:07.444 --> 00:04:09.329
Cooling qualification is still open.