main
John Lauer Record six R11 clip approvals and assemble caption-clean review chapter 5962882
{
  "title": "Electronic load R11 \u2014 design progression review",
  "clips": [
    {
      "id": "01-board",
      "title": "Compact PCB revision",
      "description": "Actual compact-board geometry orbit. Copper and silk are omitted by the STEP view; cooler not fitted.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/01-board-review.mp4",
      "warnings": [
        "Review clip only; not assembled design or physical qualification."
      ],
      "narration": "The compact revision is seventy-two millimeters square. Large corner pins stay on the scaffold grid, and USB-C sits at the edge. The four-wire fan connector and its control circuit are now routed. This is a geometry review; cooling qualification is still open."
    },
    {
      "id": "02-fan",
      "title": "RPM-controlled fan digital twin (simulated)",
      "description": "Recorded simulated fan state ramp with fixed housing and wires. Visual slow motion, no hardware measurement.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/02-fan-review.mp4",
      "warnings": [
        "Review clip only; not assembled design or physical qualification."
      ],
      "narration": "The new fan has separate speed feedback and PWM control wires. Its digital twin keeps the housing and wires fixed while the rotor turns. The simulated cycle gently varies the speed and returns to rest. The animation runs in slow motion; measured cooling still needs an actual test."
    },
    {
      "id": "03-thermal",
      "title": "Q1 external heat path: assumptions versus qualification",
      "description": "Authored chart of the actual exploratory network solve, not a screen recording or resolved fin-temperature map.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/03-thermal-review.mp4",
      "warnings": [
        "Hypothetical airflow and interface values; no thermal pass or higher power rating."
      ],
      "narration": "The thermal model needs the complete heat path: from Q one, through its insulating interface, into the heatsink, and out to the air. This comparison uses explicit cooling assumptions. It shows why fan failure matters, but it does not qualify the assembly or increase our five watt rating."
    },
    {
      "id": "04-clearance",
      "title": "Probe checker repair sends the board back to placement",
      "description": "Actual Pup saved-result review at 1.25x, followed by a native render of the DRC-clean relocation candidate. Cooler geometry is provisional; replay acceptance pending.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/04-clearance-review.mp4",
      "warnings": [
        "Saved-result review, not live solver footage. Revised cooler assembly is not qualified."
      ],
      "narration": "The bare board cleared the probes, but adding the cooler exposed a bug: the checker was skipping large objects. After fixing it, the replay found real collisions and wire snags. That sends this design back to placement, where we move the probe ground and the five volt test point into the access corridor."
    },
    {
      "id": "05-sidefan",
      "title": "Side-fan layout clears the nominal probe replay",
      "description": "Actual saved-model review at 1.25x and native v5 render. The 90-degree workcell orientation and relocated ground clear the main cooling envelopes; mount and harness are still missing.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/05-sidefan-review.mp4",
      "warnings": [
        "Geometry-only STEP review omits copper and silk; native still includes them. Cooling bodies are envelopes, not a complete qualified assembly."
      ],
      "narration": "We turned the fan toward the side of the board, and rotated the molecule to suit the probe head. A new ground contact position keeps the tether clear. The revised board passes native rule checks, and the replay clears these cooling envelopes. The mounting hardware and fan harness still need their own review."
    },
    {
      "id": "06-current",
      "title": "Fresh v5 current screen",
      "description": "Actual live Fields net selection, 1.59x. Explicit current-only presentation; invalid assembly thermal inference excluded.",
      "raw_path": "/home/adom/project/adom-custom-electronic-load/videos/compact-r11/chapter/06-current-review.mp4",
      "warnings": [
        "Computed current screen, not measurement or thermal acceptance. Temporary UI note and crop isolate current results; saved solver data is unchanged."
      ],
      "narration": "These are calculated current densities on the revised copper. All six networks pass the screen. Cooling qualification is still open."
    }
  ],
  "approval": {
    "userApproved": true,
    "recordedAt": "2026-10-14T14:20:13.883519+00:00",
    "userQuote": "Approve the six R11 clips",
    "clipIds": [
      "01-board",
      "02-fan",
      "03-thermal",
      "04-clearance",
      "05-sidefan",
      "06-current"
    ],
    "scope": "Six existing R11 review clips only; not approval of engineering qualification or later footage."
  }
}