main
John Lauer Record Board34 passive clearance studies and distinguish unscored simulation observations f7a407d
"""Conservative steady-state sensitivity; not installed thermal qualification."""
import json
from pathlib import Path
root=Path(__file__).resolve().parents[1]
w=5.5; ambient=40.; rcs=.6727626557059773; rjc=.42; rsa=1.522
rows=[]
for sink_multiplier in [1,1.1,1.2,1.3,1.5]:
 for contact_multiplier in [1,1.25,1.5,2]:
  case=ambient+w*(rsa*sink_multiplier+rcs*contact_multiplier)
  junction=case+w*rjc
  rows.append(dict(sinkMultiplier=sink_multiplier,contactMultiplier=contact_multiplier,caseC=case,junctionC=junction,caseBelow55C=case<=55,conservativePackageRiseBelow15C=junction-ambient<=15))
out={'status':'unadopted-parametric-screen','sourceW':w,'ambientC':ambient,'method':'All Q1 heat through sink; no board cooling credit. Multipliers are sensitivity scenarios, not measured tolerances.','nominalKPerW':{'caseSink':rcs,'junctionCase':rjc,'sinkAmbient':rsa},'rows':rows,'conclusion':'Nominal passes; +10 percent sink resistance exceeds the strict 15 C package-rise screen. Installed conditions and contact assumptions require resolution before adoption.'}
p=root/'mechanical/thermal-alternatives/passive-sensitivity.json';p.write_text(json.dumps(out,indent=2)+'\n');print(p)