main
John Lauer Adopt DRC-clean v85 and passing exact-board current screen; retain open cooling validation and reviewed build clips a897f04
"""Independent package-path sensitivity screen. Never substitutes for AIFlow/Fields evidence."""
import hashlib
import json
import math
from pathlib import Path

IN2_TO_MM2 = 25.4 ** 2

def area_resistance(value_c_in2_w, area_mm2):
    if not all(math.isfinite(v) for v in (value_c_in2_w, area_mm2)) or area_mm2 <= 0 or value_c_in2_w < 0:
        raise ValueError('Positive finite contact area required')
    return value_c_in2_w * IN2_TO_MM2 / area_mm2

def slab_resistance(thickness_mm, conductivity_w_mk, area_mm2):
    if not all(math.isfinite(v) for v in (thickness_mm, conductivity_w_mk, area_mm2)) or min(thickness_mm, conductivity_w_mk, area_mm2) <= 0:
        raise ValueError('Positive thickness, conductivity and area required')
    return thickness_mm * 1000 / (conductivity_w_mk * area_mm2)

def temperatures(power_w, ambient_c, r_jc, r_interface, r_spreading, r_sink):
    values = [power_w, ambient_c, r_jc, r_interface, r_spreading, r_sink]
    if not all(math.isfinite(v) for v in values) or min(power_w, r_jc, r_interface, r_spreading, r_sink) < 0:
        raise ValueError('Finite inputs and nonnegative power/resistances required')
    sink = ambient_c + power_w * r_sink
    case = sink + power_w * (r_spreading + r_interface)
    return {'sinkC': sink, 'caseC': case, 'junctionC': case + power_w * r_jc}

def main():
    root = Path(__file__).resolve().parents[1]
    power = float(json.loads((root/'design/spec.json').read_text())['hot']['Q1']['watts'])
    area = 129.961768906  # generic KiCad nominal face, not qualified IXYS contact area
    interfaces = {
        'K1300 typical area-normalized': area_resistance(.2, area),
        '173-7 one-square-inch test scaled': area_resistance(.33, area),
        'AlN + two 122 grease films, illustrative': slab_resistance(.635, 170, area) + 2 * area_resistance(.02, area),
    }
    scenarios = []
    for label, interface in interfaces.items():
        for flow, sink in [(200, 2.2), (400, 1.7), (700, 1.3)]:
            t = temperatures(power, 40, .42, interface, .3, sink)
            scenarios.append({'interface': label, 'ductedLfm': flow,
                'rInterfaceKPerW': interface, 'rSinkKPerW': sink,
                **t, 'tripMarginC': 55 - t['caseC'],
                'meetsIllustrative3CDeratingMargin': t['caseC'] <= 52})
    stock_scenarios = [{'interface': label, 'sink': 'Wakefield 680-125220', 'ductedLfm': 400, 'rInterfaceKPerW': interface, 'rSinkKPerW': 1.5, **temperatures(power, 40, .42, interface, .3, 1.5)} for label, interface in interfaces.items()]
    report = {
        'status': 'sensitivity-only-unqualified', 'acceptance': False,
        'boardSha256': hashlib.sha256((root/'kicad/adom-custom-electronic-load.kicad_pcb').read_bytes()).hexdigest(),
        'powerW': power, 'ambientC': 40, 'tripC': 55, 'illustrativeOperatingMarginC': 3,
        'contactAreaMm2': area, 'rJunctionCaseKPerW': .42,
        'assumedAdditionalSpreadingKPerW': .3,
        'assumptions': [
            f'All {power:g} W follows the package case path; no benefit credited to PCB cooling.',
            'Nominal contact area comes from generic CAD, not a guaranteed contact drawing.',
            'Interface figures are typical/test-area conversions, not production maxima.',
            'Additional 0.3 K/W spreading is a sensitivity assumption, not a solved bound.',
            '3 C operating margin is an engineering screening choice, not sensor-error qualification.',
            'ATS ducted velocities are scenarios, not achieved flow with the Sunon fan.',
        ],
        'sources': {
            'sink': 'https://www.qats.com/DataSheet/ATS-CPX040040020-115-C1-R0',
            'wakefieldTIM': 'https://wakefieldthermal.com/content/data_sheets/Thermal%20Interface%20Materials.pdf',
            'aln': 'https://wakefieldthermal.com/wakefield-thermal-25x14x0-635-to-220-aluminum-nitride-pad-178-25-220/',
            'k1300': 'https://datasheets.tdx.henkel.com/BERGQUIST-SIL-PAD-TSP-K1300-en_GL.pdf',
        },
        'unresolved': ['Exact contact geometry and insulating pad hole drawing',
            'AlN page conflicts: title 25 mm length, table 20 mm',
            'Fastener, shoulder insulation, clamp load and package support',
            'Heatsink attachment and fan duct geometry',
            'Installed pressure/flow and spreading resistance',
            'Physical stall, thermal-trip, insulation and mechanical tests'],
        'scenarios': scenarios,
        'stockSinkScenarios': stock_scenarios,
    }
    (root/'mechanical/package-cooling-budget.json').write_text(json.dumps(report, indent=2)+'\n')
    print(json.dumps({'status':report['status'], 'acceptance':False, 'scenarios':scenarios},indent=2))

if __name__ == '__main__':
    main()