main
John Lauer Fix control session reconnect and document manufacturer cooler and carrier studies 2d111fd
"""Inspect manufacturer 9099 extrusion; local-only cut model, no redistribution grant."""
from pathlib import Path
import json,hashlib,math
import cadquery as cq
from step_geometry import load_step
R=Path(__file__).resolve().parents[1];O=R/'mechanical/passive-assembly-study'
p=R/'mechanical/vendor/125319_125320_125321.STEP';s=load_step(p)
assert len(s.Solids())==1 and s.isValid()
b=s.BoundingBox();source_dims=[b.xlen,b.ylen,b.zlen]
assert all(abs(a-v)<1e-6 for a,v in zip(source_dims,[76.0984,50.8,304.8]))
normalized=s.translate((-b.xmin,-b.ymin,-b.zmin))
crop=cq.Workplane('XY').box(80,55,76.2,centered=(False,False,False)).translate((-1,-1,0)).val()
cut=normalized.intersect(crop)
assert cut.isValid() and len(cut.Solids())==1 and abs(cut.Volume()/s.Volume()-.25)<1e-8
placed=cut.rotate((0,0,0),(1,0,0),90).translate((112.5,95.7,7.25))
cq.exporters.export(placed,str(O/'vendor-125319-3inch-local-only.step'))
def box(bounds):
 x,y,z,X,Y,Z=bounds;return cq.Workplane('XY').box(X-x,Y-y,Z-z,centered=(False,False,False)).translate((x,y,z)).val()
audit=json.loads((R/'checkpoints/board32-temperature-bound/passive-body-audit.json').read_text())
assert audit['boardSha256']==hashlib.sha256((R/'aiflow/run/board-32.kicad_pcb').read_bytes()).hexdigest()
def aabb_overlap(a,b):
 return all(max(getattr(a,k+'min'),getattr(b,k+'min'))<min(getattr(a,k+'max'),getattr(b,k+'max'))-1e-7 for k in 'xyz')
conflicts=[];board_exact=0
for r in audit['rows']:
 obstacle=box(r['boundsMm'])
 if aabb_overlap(placed.BoundingBox(),obstacle.BoundingBox()):
  board_exact+=1
  if placed.intersect(obstacle).Volume()>1e-6:conflicts.append(r['ref'])
print('Board broad-phase complete:',board_exact,'exact tests;',len(conflicts),'conflicts',flush=True)
old_carrier=load_step(R/'mechanical/scaffold-stack-study/carrier/carrier-layout.step').translate((100,-100,-2.8)).mirror('XZ')
carrier_overlaps=[]
for i,obstacle in enumerate(old_carrier.Solids()):
 if aabb_overlap(placed.BoundingBox(),obstacle.BoundingBox()):
  volume=placed.intersect(obstacle).Volume()
  if volume>1e-6:carrier_overlaps.append({'solidIndex':i,'overlapMm3':volume})
  print('Carrier solid',i,'overlap',volume,flush=True)
bb=placed.BoundingBox()
report={'status':'manufacturer-model-local-review-not-adopted','sourceUrl':'https://wakefieldthermal.com/content/Models/ThermalExtrusion/125319_125320_125321.STEP','productUrl':'https://wakefieldthermal.com/wakefield-thermal-3x12-in-extrusion-9099-125319/','sourceSha256':hashlib.sha256(p.read_bytes()).hexdigest(),'boardSha256':audit['boardSha256'],'sourceDimensionsMm':source_dims,'sourceSolids':1,'sourceValid':True,'cutLengthMm':76.2,'cutVolumeMm3':cut.Volume(),'cutValid':True,'sourceToBoardTransform':'Subtract original bounds minimum; clip originalZ to[0,76.2]; rotate+90deg aboutX; translate(112.5,95.7,7.25)mm','placedBoundsMm':[bb.xmin,bb.ymin,bb.zmin,bb.xmax,bb.ymax,bb.zmax],'catalogBaseThicknessMm':.280*25.4,'estimatedAluminumMassGramsAt2700kgM3':cut.Volume()*.0027,'fittedBoardBodyConflicts':conflicts,'oldCarrierSolidOverlapSumMm3':sum(r['overlapMm3'] for r in carrier_overlaps),'oldCarrierOverlaps':carrier_overlaps,'boardExactTestsAfterBroadPhase':board_exact,'catalogNaturalKPerW':1.5,'productPageNaturalKPerW':1.522,'conditionalCaseCAt5p5W40CWithAssumedInterface':40+5.5*(1.522+.52731),'limitations':['Manufacturer shared file spans125319/125320/125321; imported model length matches12531912inch stock. No supplier-made3inch part is claimed.','Cut geometry is a local research derivative, not a fabrication drawing. Kerf, end finish, mounting holes, tolerances and thermal source placement are unqualified.','No redistribution permission established; vendor STEP and derivatives excluded from Wiki publication. Publish source URL, hash and findings only.','Old carrier file includes structural parts, old sink envelope and nominal fan. Per-solid overlap sum is not a union or structural-only volume.','Density is an assumed mass estimate, not manufacturer declared weight. Support must carry this mass independently of MOSFET leads.','Catalog1.5 and current product1.522K/W differ by rounding; neither is an installed low-rise thermal qualification.']}