main
John Lauer
Connect fresh measured fan telemetry to read-only assembly twin; record disconnected behavior
2d7dc33
import assert from 'node:assert/strict';
import {fanFromTelemetry as map} from '../control-panel/twin/telemetry.mjs';
const good={connected:true,mode:'hardware',rpm_valid:true,rpm:7000,telemetry_age_ms:50};
assert.equal(map(good).valid,true);assert.equal(map(good).speed,7000);assert.equal(map({...good,rpm:0}).state,'off');
for(const patch of [{connected:false},{mode:'simulated'},{rpm_valid:false},{rpm:null},{rpm:NaN},{rpm:10001},{rpm:-1},{telemetry_age_ms:null},{telemetry_age_ms:1600}])assert.equal(map({...good,...patch}).valid,false,JSON.stringify(patch));
assert.equal(map(good,1451).valid,false);assert.equal(map(good,1501).valid,false);assert.equal(map(null).valid,false);
assert.equal(map({connected:false,rpm:0,rpm_valid:false}).valid,false,'disconnect is not a confirmed stopped fan');
console.log('PASS: measured-only RPM, explicit zero, stale server/client data, invalid readings and disconnect remain distinct');