John Lauer Start compact R11 AIFlow revision; preserve Board34 and record initial fit and fan-control findings 940efe6

Compact R11 sourcing review

13 October 2026. Candidates only; no orders placed.

  • Sunon AF40100VX-1000U-S99: documented 40 x 40 x 10 mm, 5 V, PWM/tach, 8000 RPM. Mouser API reports no stock and 190-day lead time; no price returned. Do not lock prototype to this part without an obtainable alternative.
  • ATS-FPX040040035-96-C3-R0: manufacturer drawing 40 x 40 x 35 mm fin assembly, 45 x 45 mm mounting hole pattern. Mouser $6.79 each, zero stock, 56-day lead time. Stock snapshot in ats.json. Factory TIM is T412, not a qualified Q1 electrical insulator.
  • Wakefield 910-40-2-33-2-B-0: manufacturer 40 mm pin-fin family; useful catalog thermal curves, but listed MOQ 1000 and no distributor stock in the researched listing. Reject for this prototype procurement path.
  • Noctua NF-A4x10 5V PWM: fully documented 4-pin, tach/PWM. Advertised 40 x 40 x 10 form factor but extended specs give 11 mm bare / 12 mm with pads. 5000 RPM maximum, so current 5000 RPM minimum-load policy leaves no tolerance; cannot substitute without thermal/protection review.

Source links:

The earlier 6.9-8.6 W concept estimate does not carry over to a sourced sink/fan automatically. Rebuild the thermal model from exact geometry and bound installed airflow.

Working fan choice

CFM-4010-03-22, Same Sky: 40 x 40 x 10.6 mm, 5 V, dual ball bearing, 7470-9130 RPM rated range, maximum 0.24 A / 1.2 W. Four bare leads: red +5 V, black ground, yellow open-collector tach, blue PWM. Datasheet page4 shows two tach cycles per revolution and a 4-5 V PWM waveform but does not specify the permitted PWM frequency or low-duty stopping behavior. These remain bench/vendor verification items; do not assume 0% guarantees stop. At full speed the rated range fits the unchanged 5000-10000 RPM load policy.

Mouser search snapshot: 1490 stock, $10.82 each. Fan cost excludes mating connector, harness and mounting. Existing 3-pin J9 must become 4-pin, with keyed housing and defined pinout. Add an open-drain PWM interface; startup defaults to full cooling while load remains locked.