John Lauer Publish compact v5 electrical checks and six captioned progression review scenes; cooling acceptance remains open ca514b5

Cooler collision review returned R11 to placement

The original 0.2.24 probe collision result was invalid: the checker treated a 4×4 mm corner primitive as the board slab, then discarded larger objects by area. Earlier clearance claims were withdrawn and success receipts removed.

An isolated candidate fix aggregates coplanar board fragments, checks their XY bounds against the transformed PCB outline, and includes large coolers and brackets crossing below the board. Sixteen workspace tests passed, including three obstacle/head regressions. The complete moving head is sampled; the former 40 mm cutoff is removed. The release build passed. Owner issue #3 and source PR #3 contain reproduction and validation. The shared installation and running simulator were not changed.

Replay Old checker obstacles Corrected obstacles Corrected collisions Corrected snags
v4 board only 4,539 4,634 0 0
v4 plus sink/fan body reservations 4,539 4,636 24 6

The corrected slab is 72×72 mm. The two added bodies demonstrably enter the obstacle set. They are only dimensional reservations: ATS mounting ears, clamp, sensor, duct and routed fan leads remain absent. Neither replay qualifies the assembled product.

During ground-pin insertion into J7, the paired probe descends into the proposed heatsink. TP14 travel crosses the fan. AIFlow has returned to placement to explore moving J7 and TP14 into the left access corridor. The original v4 checkpoint remains intact. The first J7/TP14 relocation passed native DRC but still failed the cooler replay (21 collision episodes, two snags). A subsequent side-fan arrangement rotates the molecule 90 degrees on the same scaffold grid. Moving J7 to local (10,4) mm and repeating a front-bank measurement before ground removal clears the nominal reservation screen. The actual v5 PCB, including a short PWM-trace detour and corrected labels, passes native DRC with zero errors, warnings and opens. Its fresh actual-model replay passes with zero collision episodes and zero snags; clamp, harness, sensor and mounting ears still must be included.

All geometry is nominal and subject to workcell/profile assumptions. A passing corrected replay will remain a screen, not physical assembly qualification.