main
John Lauer Resolve load current-path issue with verified board22 broader source pour; preserve remaining thermal and service gates e2348d8
import pcbnew,pathlib,shutil,subprocess
p=pathlib.Path('C:/Users/arav/Downloads/electronic-load-issue-1');src=p/'source-receiver-spread.kicad_pcb';dst=p/'source-upper-pour.kicad_pcb'
for ext in ['.kicad_pro','.kicad_dru']:shutil.copyfile(src.with_suffix(ext),dst.with_suffix(ext))
m=pcbnew.GetSettingsManager();m.LoadProject(str(dst.with_suffix('.kicad_pro')));b=pcbnew.LoadBoard(str(src));b.SetProject(m.GetProject(str(dst.with_suffix('.kicad_pro'))))
for z in b.Zones():
 if z.GetNetname()=='SHUNT_P' and z.GetLayer()==pcbnew.B_Cu:
  o=z.Outline();o.RemoveAllContours();o.NewOutline()
  for x,y in [(123.7,80.8),(133.8,80.8),(133.8,82.8),(135.4,84.7),(138,84.7),(138,88),(134.5,88),(133.5,86.0),(124,86.0),(123.7,83.6)]:o.Append(int(x*1e6),int(y*1e6))
pcbnew.ZONE_FILLER(b).Fill(b.Zones());pcbnew.SaveBoard(str(dst),b)
r=subprocess.run(['C:/Users/arav/AppData/Local/Programs/KiCad/10.0/bin/kicad-cli.exe','pcb','drc','--format','json','--output',str(p/'source-upper-pour-drc.json'),str(dst)],capture_output=True,text=True);print(r.stdout,r.stderr)