main
John Lauer Resolve load current-path issue with verified board22 broader source pour; preserve remaining thermal and service gates e2348d8
{
  "boardSha256": "197e48d41c905773c8c8db092c9db5a255f0b0b919eaf3b645080399c93467d7",
  "nativeDrcErrors": 0,
  "nativeDrcWarnings": 0,
  "nativeDrcUnconnected": 0,
  "nativeDrcReport": "revisions/compact-r11/issue-1-copper/source-upper-pour-drc.json",
  "changes": [
    "Broaden SHUNT_P B.Cu pour upper boundary from manually pinched corner to x133.8/y80.8; native refill preserves other-net clearance, all existing pad positions, routing and source/receiver feed additions retained from board19"
  ],
  "fullFields": "revisions/compact-r11/issue-1-copper/fields-upper-pour-fine/fields.json",
  "shuntPeakAperMm2": 57.31575393676758,
  "acceptance": "AIFlow 0.2.26 current analysis passed after adoption. Full unchanged-spec 0.1 mm loaded-net peaks below 60 A/mm2. Native DRC zero errors, warnings and opens. Thermal, mechanical, wiring and fabrication qualification remain open.",
  "activeBoard": "aiflow/compact-r11/board-22.kicad_pcb",
  "aiFlowCurrentLog": "revisions/compact-r11/issue-1-copper/current-board22-fine.txt"
}