main
John Lauer Publish failed board-20 full fine-grid evidence and keep current-limit gate intact f3ac3a7
WARNING: still in current after 44 min (expected about 15 min); declare the step you are actually on (`step thermal`, `step fields`, `step nets`, ...), even when your own scripts do that step's work. The timeline, the clips and the video depend on it.
why:
  SHUNT_P: neck at (126.0, 82.8) on B.Cu: widen SHUNT_P in `wideNets`, or give it a patch pour there.
ERROR: current analysis not passed:
5V_AUX pass: the narrowest listed track carries the full specified load within 10 C
DUT_FUSED pass: branch currents give 5.34 C maximum track estimate against 10.00 C; barrel density 0.00 against 60.00 A/mm2; all through-terminal layer extremes checked
DUT_POS pass: branch currents give 3.96 C maximum track estimate against 10.00 C; barrel density 47.45 against 60.00 A/mm2; all through-terminal layer extremes checked
GND pass: pour on B.Cu+F.Cu (5789 mm2 filled) carries the load; tracks are 1.50 mm at most; the GND pour covers every piece too narrow for 3.0 A on its own layer (66 pieces)
LOAD_POS pass: pour on B.Cu+F.Cu (389 mm2 filled) carries the load; tracks are 1.75 mm at most; one B.Cu+F.Cu pour reaches all 2 LOAD_POS terminals, so the narrow tracks run beside it
SHUNT_P pass: pour on B.Cu+F.Cu (39 mm2 filled) carries the load; tracks are 2.30 mm at most; one B.Cu+F.Cu pour reaches all 2 SHUNT_P terminals, so the narrow tracks run beside it
(field screen: Fields SHUNT_P peak current density exceeds the 60 A/mm2 screen (128.3 A/mm2 at (126.05, 82.75) on B.Cu; a reviewed part-limited peak takes `analyze current --ack [email protected] --why ...`))
Hint: Fix what the failing lines say (pours, vias, widths, or placement), land it, measure again, then analyze again.
Hint: Now do the analysis yourself, not only this table: draw the current density on the copper (amps per square millimetre on every loaded net's pours and tracks; a Laplace solve on the filled copper between the source pads and the sink pads is enough, the board file has the filled polygons) as a 1920x1080 PNG with a colour scale, then `artifact --kind analysis-image --file <png> --caption "..."`. It becomes a fullscreen shot in the final video and a figure on the run page.
Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets GND,LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).
Hint: Input of `analyze current` (skill aiflow-power-layout): read /home/adom/.claude/skills/aiflow-power-layout/SKILL.md or /home/adom/project/adom_modules/adom/adom-aiflow/skills/aiflow-power-layout/SKILL.md, section "Input schemas"; also /home/adom/project/adom_modules/adom/adom-aiflow/docs/plan-schema.md.