John Lauer Publish input-bound R11 prototype bundle and completed CLI clearance review 7007e93
20 measurements: 19 ok, 0 on a component pad, 1 near, 0 proposed, 0 missing (0 required)
  OK       power-in     5V_AUX     panel   via J3
  OK       rail-3v3     3V3        probe   at TP7
  OK       rail-5v-aux  5V_AUX     probe   at TP14
  OK       rail-vref-2v5 VREF_2V5   probe   at TP15
  OK       vout         5V_AUX     probe   at TP14
  OK       sw           BOOST_SW   probe   at TP16
  NEAR     l-out        5V_AUX     probe   at TP14  (L1 itself cannot be probed; TP14 on the same net is the nearest landing)
  OK       tp-tp13      SHUNT_N_SENSE probe   at TP13
  OK       tp-tp6       V_GATE     probe   at TP6
  OK       tp-tp4       I_SET      probe   at TP4
  OK       tp-tp3       SHUNT_P_SENSE probe   at TP3
  OK       tp-tp17      FAN_PWM    probe   at TP17
  OK       tp-tp2       LOAD_POS   probe   at TP2
  OK       tp-tp1       DUT_POS    probe   at TP1
  OK       tp-tp9       HW_OK      probe   at TP9
  OK       tp-tp5       GATE       probe   at TP5
  OK       tp-tp10      LATCH_Q    probe   at TP10
  OK       tp-tp8       TEMP_SENSE probe   at TP8
  OK       tp-tp12      FAN_TACH   probe   at TP12
  OK       ground       GND        ground  at J11
OK: coverage.json written: the board can be probed
Hint: l-out (recommended): L1 itself cannot be probed; TP14 on the same net is the nearest landing
Hint: workcell fact: coverage: prove the board can be probed BEFORE it is ordered; every gap found now is a board change in adom-aiflow (add a test point, move a part), not a bench workaround
Hint: workcell fact: coverage: a power board needs at least VIN on the board (not just at the supply), VOUT, the switch node at the inductor's input, the inductor's output side, feedback, the biggest bulk capacitor, every indicator LED (camera) and a free GND contact for the probe's ground pin
Hint: workcell fact: coverage: VIN comes from a Control Panel supply (PS1, current-limited) through a wired machine contact; that contact holds the wire's pin, so VIN is probed somewhere else on the board
Hint: workcell fact: coverage: an LED is a camera check (the overhead camera, probe parked clear), not a probe point
Hint: workcell fact: coverage: the probe tip (0.3 mm, +-0.15 mm XY) can land on a test point or the outer half of a component pad; the body (4 mm radius) must clear every part taller than the needle's 6 mm free length (assumed until Stephen's P250BR3 CAD)
Hint: Use the landings in coverage.json when you write plan.json (test, probe point per measurement); `plan check` cross-checks them.
Hint: next step refs: Run `adom-aiflow-probing refs` (re-runs the design's switching netlist at each VIN and reads any vendor-model CSDF). Check the printed metrics match the numbers the design reported; if they do not, stop and find out why before planning against them.