253cc27
Q1 heat flow through FR4 and the cooler
This is a separate reduced Q1-only steady-state model, not a validated whole-board simulation. It joins a72x72x1.6mm FR4 body, three simplified bent leads/local pads, Q1 contact, insulation, base and fins. Q1 supplies5.5W. Exact copper pours, vias, package internals, D1/shunt/Joule losses, radiation and actual airflow are omitted. FR4 conductivity is scalar0.3W/mK. Lead geometry and material are assumptions.
Fan off/on prescribe sink convection5/50W/m²K and board10/25W/m²K. These are sensitivity parameters, not measured fan performance. Surface colours show temperature on a common40–90°C scale. Moving internal markers follow sampled signed conductive-face heat flux in W/m²; their speed and display length are illustrative. They remain visible through solids. Switching cases is not a time-dependent cooldown.
An initial trial injected D1 heat directly into bare FR4 without its copper spreader and yielded a misleading hotspot. That trial was rejected rather than presented as the actual board. The displayed model explicitly limits its source to Q1.
The2mm model gives case82.17°C/49.24°C and FR4 maxima60.01°C/43.74°C for off/on at40°C ambient. These are reduced-model outputs, not actual product temperatures or fabrication acceptance. Neither thermal gate nor power limit changes. comparison.json contains numerical convergence and energy-balance checks; mesh refinement and experimental validation remain required.
# Q1 heat flow through FR4 and the cooler
This is a separate **reduced Q1-only steady-state model**, not a validated whole-board simulation. It joins a72x72x1.6mm FR4 body, three simplified bent leads/local pads, Q1 contact, insulation, base and fins. Q1 supplies5.5W. Exact copper pours, vias, package internals, D1/shunt/Joule losses, radiation and actual airflow are omitted. FR4 conductivity is scalar0.3W/mK. Lead geometry and material are assumptions.
Fan off/on prescribe sink convection5/50W/m²K and board10/25W/m²K. These are sensitivity parameters, not measured fan performance. Surface colours show temperature on a common40–90°C scale. Moving internal markers follow sampled signed conductive-face heat flux in W/m²; their speed and display length are illustrative. They remain visible through solids. Switching cases is not a time-dependent cooldown.
An initial trial injected D1 heat directly into bare FR4 without its copper spreader and yielded a misleading hotspot. That trial was rejected rather than presented as the actual board. The displayed model explicitly limits its source to Q1.
The2mm model gives case82.17°C/49.24°C and FR4 maxima60.01°C/43.74°C for off/on at40°C ambient. These are reduced-model outputs, not actual product temperatures or fabrication acceptance. Neither thermal gate nor power limit changes. `comparison.json` contains numerical convergence and energy-balance checks; mesh refinement and experimental validation remain required.