"model": "single-path sizing bound; excludes shared board heating and transients",
"q1PowerW": 5.5,
"maxJunctionRiseC": 15,
"junctionCaseKPerW": 0.42,
"assumedCaseSinkKPerW": 0.7,
"requiredSinkAmbientAtMostKPerW": 1.6072727272727272,
"assumedStillSinkAmbientKPerW": 8,
"assumedMovingSinkAmbientKPerW": 1.2,
"stillPowerAt15CRiseW": 1.6447368421052633,
"movingPowerAt15CRiseW": 6.4655172413793105,
"coupledScenario": {
"chipRisePolicy": "maximum of board terminal region, case and junction; never hide a hot external node",
"definition": {
"boardLinks": [
{
"at": [
130.0,
82.0
],
"layer": "F.Cu",
"pad": "1",
"resistanceKPerW": 100.0
},
{
"at": [
127.46,
82.0
],
"layer": "F.Cu",
"pad": "2",
"resistanceKPerW": 100.0
},
{
"at": [
124.92,
82.0
],
"layer": "F.Cu",
"pad": "3",
"resistanceKPerW": 100.0
}
],
"caseSinkKPerW": 0.7,
"junctionCaseKPerW": 0.42,
"provenance": "R11 exploratory package-path scenario only. Rjc .42 from IXTP15N50L2 datasheet; interface .7 K/W, passive8 K/W and each lead100 K/W are explicit sensitivity parameters, not accepted assembly properties. Moving1.2 K/W is an ATS catalog ducted100LFM scenario, not measured installed airflow. No R10 qualification transfer. Does not qualify cooler, mounting, transient or prototype.",
"reference": "Q1",
"sinkAmbientMovingKPerW": 1.2,
"sinkAmbientStillKPerW": 8.0
},
"moving": {
"boardCouplingW": 0.006871121284866888,
"boardLinks": [
{
"boardRiseC": 10.146319592904206,
"caseToBoardW": 0.00290625276787317
},
{
"boardRiseC": 10.221565145171981,
"caseToBoardW": 0.0021537972451954168
},
{
"boardRiseC": 10.255837742511693,
"caseToBoardW": 0.0018110712717983013
}
],
"caseRiseC": 10.436944869691523,
"energyResidualW": -4.982787515928067e-10,
"junctionRiseC": 12.746944869559686,
"sinkRiseC": 6.591754655056094,
"sinkToAmbientW": 5.493128879213412,
"sourceW": 5.5
},
"status": "supplied-parameter-steady-state-screen",
"still": {
"boardCouplingW": 0.07016386813306633,
"boardLinks": [
{
"boardRiseC": 44.825678303643244,
"caseToBoardW": 0.02413896029174623
},
{
"boardRiseC": 44.91088448096702,
"caseToBoardW": 0.023286898518508466
},
{
"boardRiseC": 44.965773400536705,
"caseToBoardW": 0.02273800932281162
}
],
"caseRiseC": 47.23957433281787,
"energyResidualW": 1.7912391570007458e-09,
"junctionRiseC": 49.54957433281309,
"sinkRiseC": 43.43868904060555,
"sinkToAmbientW": 5.429836130075694,
"sourceW": 5.5
},
"transientQualified": false
},
"accepted": false,
"note": "Sizing calculation only. Do not change 5W output cap, 5.5W design case or 15C acceptance limit. Fan-off shutdown requires transient safety proof and does not waive the current still-air gate."
}