main
John Lauer
Record validated fan replay and failed unducted thermal sensitivity without changing limits
43dc79f
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629
{
"board": "Compact R11 packing candidate: 72 x 72 mm; unvalidated",
"copperUm": 35,
"clearance": 0.2,
"edgeClearance": 0.2,
"fixedRefs": [
"MP1",
"MP2",
"MP3",
"MP4",
"J1",
"J2",
"J3",
"J4",
"J5",
"J6",
"J7"
],
"wideNets": {
"DUT_POS": [
2.0,
1.5,
1.2
],
"DUT_FUSED": [
2.0,
1.5,
1.2
],
"LOAD_POS": [
2.0,
1.5,
1.2
],
"SHUNT_P": [
2.0,
1.5,
1.2
],
"GND": [
2.0,
1.5,
1.2
]
},
"midNets": {
"5V_AUX": [
0.5,
0.4
],
"V_GATE": [
0.3,
0.25
]
},
"kelvin": {
"U4.10": "RSH1.2",
"U4.9": "RSH1.3"
},
"chains": [
{
"refs": [
"R8",
"R9",
"R10"
],
"direction": "down"
},
{
"refs": [
"R18",
"R19"
],
"direction": "down"
},
{
"refs": [
"R22",
"R23"
],
"direction": "down"
},
{
"refs": [
"R27",
"R28"
],
"direction": "down"
},
{
"refs": [
"R35",
"R36",
"R37"
],
"direction": "down"
}
],
"loads": {
"DUT_POS": {
"amps": 3.000220385674931,
"maxRiseC": 10,
"terminals": [
{
"reference": "J1",
"pad": "1",
"amps": 3.000220385674931
},
{
"reference": "F1",
"pad": "1",
"amps": -3
},
{
"reference": "R24",
"pad": "1",
"amps": -0.00022038567493112948
},
{
"reference": "TP1",
"pad": "1",
"amps": 0
}
],
"currentModel": "resistive-branches"
},
"DUT_FUSED": {
"amps": 3,
"maxRiseC": 10,
"currentModel": "resistive-branches",
"terminals": [
{
"reference": "F1",
"pad": "2",
"amps": 3
},
{
"reference": "D1",
"pad": "2",
"at": [
117.638,
91.92
],
"amps": -1.5
},
{
"reference": "D1",
"pad": "2",
"at": [
117.638,
90.08
],
"amps": -1.5
}
]
},
"LOAD_POS": {
"amps": 3.0000289156626505,
"maxRiseC": 10,
"terminals": [
{
"reference": "D1",
"pad": "1",
"amps": 3.0000289156626505
},
{
"reference": "Q1",
"pad": "2",
"amps": -3
},
{
"reference": "U4",
"pad": "8",
"amps": -2.891566265060241e-05
}
]
},
"SHUNT_P": {
"amps": 3,
"maxRiseC": 10,
"terminals": [
{
"reference": "Q1",
"pad": "3",
"amps": 3
},
{
"reference": "RSH1",
"pad": "1",
"amps": -3
}
]
},
"GND": {
"amps": 3,
"maxRiseC": 10,
"terminals": [
{
"reference": "RSH1",
"pad": "4",
"amps": 3
},
{
"reference": "J2",
"pad": "1",
"amps": -3
}
]
},
"5V_AUX": {
"amps": 0.5,
"maxRiseC": 10,
"budgetNote": "Strengthened 0.5 A continuous conductor screening allowance: selected fan maximum0.24A, remaining0.26A reserved for logic/boost/control. This is a design budget, not measured startup current. No physical supply setting changed."
}
},
"hot": {
"D1": {
"watts": 0.5133333333333333,
"tabNet": "LOAD_POS"
},
"RSH1": {
"watts": 0.030025925925925928,
"tabNet": "SHUNT_P"
},
"Q1": {
"watts": 5.5,
"tabNet": "LOAD_POS",
"maxRiseC": 15,
"note": "Compact cooler path not yet qualified or supplied. Do not reuse Board34/R10 packageCooling."
}
},
"hotMaxRiseC": 35,
"pours": [
{
"name": "Top return and shield",
"net": "GND",
"layers": [
"F.Cu"
],
"polygon": [
[
96.3,
32.2
],
[
167.7,
32.2
],
[
167.7,
103.7
],
[
96.3,
103.7
]
],
"priority": 0,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "Shunt positive spread front",
"net": "SHUNT_P",
"layers": [
"F.Cu"
],
"polygon": [
[
134.5,
84.7
],
[
138.0,
84.7
],
[
138.0,
88.0
],
[
134.5,
88.0
]
],
"priority": 3,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "D1 relocated heat spread front",
"net": "LOAD_POS",
"layers": [
"F.Cu"
],
"polygon": [
[
114.0,
82.0
],
[
132.0,
82.0
],
[
132.0,
99.0
],
[
104.0,
99.0
],
[
104.0,
89.4
],
[
114.0,
89.4
]
],
"priority": 3,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "Shunt positive spread back",
"net": "SHUNT_P",
"layers": [
"B.Cu"
],
"polygon": [
[
134.5,
84.7
],
[
138.0,
84.7
],
[
138.0,
88.0
],
[
134.5,
88.0
]
],
"priority": 3,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "Power return and signal reference",
"net": "GND",
"layers": [
"B.Cu"
],
"polygon": [
[
96.3,
32.2
],
[
167.7,
32.2
],
[
167.7,
103.7
],
[
96.3,
103.7
]
],
"priority": 0,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "D1 relocated heat spread back",
"net": "LOAD_POS",
"layers": [
"B.Cu"
],
"polygon": [
[
118.8,
70.0
],
[
132.0,
70.0
],
[
132.0,
99.0
],
[
104.0,
99.0
],
[
104.0,
89.4
],
[
114.0,
89.4
],
[
114.0,
84.0
],
[
118.8,
84.0
]
],
"priority": 3,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
},
{
"name": "Q1 source to shunt current spread back",
"net": "SHUNT_P",
"layers": [
"B.Cu"
],
"polygon": [
[
124.2,
82.8
],
[
125.6,
82.4
],
[
127.0,
82.8
],
[
133.8,
82.8
],
[
135.4,
84.8
],
[
135.4,
85.4
],
[
133.5,
85.2
],
[
126.0,
85.2
],
[
124.2,
83.6
]
],
"priority": 4,
"connection": "solid",
"clearance": 0.2,
"minThickness": 0.25
}
],
"notPoured": [
"BOOST_SW",
"SERVO_FB",
"SHUNT_P_SENSE",
"SHUNT_N_SENSE",
"I_SET",
"DAC_OUT",
"SET_DIV"
],
"fab": {
"rules": "fab",
"target": "fab"
},
"sourcing": {
"profile": "fab"
},
"molecule": {
"pin": "large",
"gridMm": 2,
"edgeMarginMm": 2,
"cornerPinsNet": "GND",
"mediumContactPitchMm": 8,
"fixed": {
"J1": [
8.0,
0.0
],
"J2": [
12.0,
0.0
],
"J3": [
20.0,
0.0
],
"J4": [
24.0,
0.0
],
"J5": [
36.0,
0.0
],
"J6": [
40.0,
0.0
],
"J7": [
40,
10
],
"MP1": [
0.0,
0.0
],
"MP2": [
64.0,
0.0
],
"MP3": [
0,
64
],
"MP4": [
64,
64
]
},
"interfaceRevision": {
"status": "unvalidated R11 candidate",
"reason": "Compact R11 large pins plus probe-driven J7 ground relocation on original 2 mm grid; no power/thermal limits changed"
}
},
"requireEvidence": [
"calcs",
"simulation"
],
"qualificationNote": "R11: all acceptance gates must be rerun. Historical R10 cooler parameters intentionally excluded.",
"planes": {
"GND": "B.Cu"
},
"netClearance": {
"USB_VBUS": 0.27
},
"stackupMm": [
1.53
],
"dcMaxIterations": 60000,
"diagnosticNote": "R11 compact cooler path remains unresolved. Do not reuse R10 package cooling. The board-only Q1 solve is a diagnostic failure screen, not the external case-to-sink path.",
"branchAssumptions": {
"DUT_POS": "24 V across a 100k/10k series divider, both -1 percent; full 3 A F1 path retained. ADC input leakage is not included.",
"LOAD_POS": "INA226 VBUS nominal 830 kohm (typical, no max specified here) gives 28.916 uA at 24 V. Nominal-only boundary, not guaranteed maximum."
},
"branchCurrentModel": {
"boardThicknessMm": 1.6,
"barrelPlatingUm": 25,
"maxBarrelDensityAperMm2": 60
},
"placement": {
"edgeConnectors": {
"J8": {
"footprint": "Connector_USB:USB_C_Receptacle_GCT_USB4105-xx-A_16P_TopMnt_Horizontal",
"edge": "maxX",
"maxCourtyardOverhangMm": 0.55,
"reason": "User requires USB-C at board edge. Board34 measured courtyard projects0.505mm; electrical pads and holes remain inside. Exact native placement DRC and saved/live identity stay mandatory. Mechanical cable/carrier clearance reviewed separately."
}
}
},
"packageCooling": [
{
"reference": "Q1",
"junctionCaseKPerW": 0.42,
"caseSinkKPerW": 0.7,
"sinkAmbientStillKPerW": 8,
"sinkAmbientMovingKPerW": 5.8,
"boardLinks": [
{
"pad": "1",
"at": [
130,
82
],
"layer": "F.Cu",
"resistanceKPerW": 100
},
{
"pad": "2",
"at": [
127.46,
82
],
"layer": "F.Cu",
"resistanceKPerW": 100
},
{
"pad": "3",
"at": [
124.92,
82
],
"layer": "F.Cu",
"resistanceKPerW": 100
}
],
"provenance": "R11 exploratory package-path scenario only. Rjc .42 from IXTP15N50L2 datasheet; interface .7 K/W, passive8 K/W and each lead100 K/W are explicit sensitivity parameters, not accepted assembly properties. Moving1.2 K/W is an ATS catalog ducted100LFM scenario, not measured installed airflow. No R10 qualification transfer. Does not qualify cooler, mounting, transient or prototype. Unducted sensitivity uses exact C2 datasheet 5.80 K/W at100 LFM, https://www.qats.com/DataSheet/ATS-FPX040040035-66-C2-R0, checked2026-10-16. Installed velocity and small Q1 contact spreading remain unqualified."
}
]
}