main
John Lauer
Prepare five-board JLC SMT quote alternatives and native package; record upload success and unresolved sign-in/rotation…
6dfd908
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879
{
"ref": "R13",
"original": "CR0402-FX-4701GLF",
"candidate": "ERJ2RKF4701X",
"lcsc": "C400631",
"verdict": "PASS",
"checks": [
{
"check": "R_ohm",
"pass": true,
"detail": "4700 vs 4700 (original +/-1 %)",
"info": false
},
{
"check": "tolerance",
"pass": true,
"detail": "1 % vs 1 %",
"info": false
},
{
"check": "voltage_V",
"pass": true,
"detail": "50 vs original 50 (needs >=)",
"info": false
},
{
"check": "power_W",
"pass": true,
"detail": "0.1 vs original 0.063 (needs >=)",
"info": false
},
{
"check": "tcr_ppm",
"pass": true,
"detail": "100 vs original 100 (needs <=)",
"info": false
},
{
"check": "temperature range",
"pass": true,
"detail": "[-55, 155] covers [-55, 155]",
"info": false
},
{
"check": "height",
"pass": true,
"detail": "0.4 mm vs 0.37 mm",
"info": false
},
{
"check": "land fit pad 1",
"pass": true,
"detail": "100 % of the terminal on pad 1 (0.50 x 0.50 at -0.50, 0.00)",
"info": false
},
{
"check": "land fit pad 2",
"pass": true,
"detail": "100 % of the terminal on pad 2 (0.50 x 0.50 at 0.50, 0.00)",
"info": false
},
{
"check": "original availability",
"pass": true,
"detail": "searched CR0402-FX-4701GLF on 2026-10-19: not found (stock None, required None)",
"info": false
}
],
"checkedAt": "2026-10-19T02:44:30Z",
"facts": "quotes/jlc-five-smt/swaps/R13.json",
"notes": "Same resistance, tolerance, TCR and voltage; higher rated power. Nominal underside terminal dimensions used for overlap; final JLC footprint-fit remains required. All same-MPN refs included.",
"bomRows": [
"R13",
"R14",
"R29",
"R30",
"R41"
]
}