"ref": "C5",
"original": "0603B103J250CT",
"candidate": "0603B103J500CT",
"lcsc": "C128615",
"verdict": "PASS",
"checks": [
{
"check": "C_uF",
"pass": true,
"detail": "0.01 vs 0.01 (original +/-5 %)",
"info": false
},
{
"check": "tolerance",
"pass": true,
"detail": "5 % vs 5 %",
"info": false
},
{
"check": "voltage_V",
"pass": true,
"detail": "50 vs original 25 (needs >=)",
"info": false
},
{
"check": "dielectric",
"pass": true,
"detail": "X7R vs X7R",
"info": false
},
{
"check": "temperature range",
"pass": true,
"detail": "[-55, 125] covers [-55, 125]",
"info": false
},
{
"check": "height",
"pass": true,
"detail": "0.95 mm vs 0.95 mm",
"info": false
},
{
"check": "land fit pad 1",
"pass": true,
"detail": "100 % of the terminal on pad 1 (0.90 x 0.95 at -0.78, 0.00)",
"info": false
},
{
"check": "land fit pad 2",
"pass": true,
"detail": "100 % of the terminal on pad 2 (0.90 x 0.95 at 0.78, 0.00)",
"info": false
},
{
"check": "original availability",
"pass": true,
"detail": "searched 0603B103J250CT on 2026-10-19: not found (stock None, required None)",
"info": false
}
],
"checkedAt": "2026-10-19T02:46:22Z",
"facts": "quotes/jlc-five-smt/swaps/C5.json",
"notes": "Same0603 10nF5percentX7R, voltage upgraded25Vto50V; no dielectric change; nominal terminal geometry.",
"bomRows": []
}