John Lauer
Integrate output-locked I2C diagnostics and conservative measurement age; retain mounting qualification limits
26c2c4b
{
"status": "nominal-centering-sensitivity-only",
"acceptance": false,
"washer": "7721-7PPSG",
"assumptions": {
"tabMaxMm": 1.4,
"stemLengthMm": 0.81,
"boreMm": 2.95,
"stemODMm": 3.43,
"screwDiameters": "2.8448 mm is nominal #4 diameter; smaller values are sensitivity inputs, not sourced thread tolerances"
},
"model": "Rigid straight cylindrical screw in a straight concentric sleeve; sleeve translates to tab-hole wall; full angular fit includes screw diameter / cos(theta).",
"rows": [
{
"screwDiameterMm": 2.8448,
"maximumTiltDegrees": 6.223737950440215,
"remainingRadialMarginMm": 0.17565815293782633
},
{
"screwDiameterMm": 2.75,
"maximumTiltDegrees": 10.62817441998488,
"remainingRadialMarginMm": 0.12928418797722285
},
{
"screwDiameterMm": 2.6,
"maximumTiltDegrees": 16.445511453185023,
"remainingRadialMarginMm": 0.06584419059654684
}
],
"limitations": [
"Thread roots and discontinuous crests are not a solid cylinder",
"No washer tolerances, deformation, wear, molding flash or eccentricity",
"No flange/tool access, pad insulation, pressure or torque verification"
]
}