main
John Lauer
Review insulated temperature sensor, route its harness and record clearance study
bbcae78
{
"status": "candidate-not-adopted",
"sensor": "NTCLE428E3103H400A",
"housing": "M20-1060200",
"contacts": "2 x M20-1180046 (not modeled)",
"boardSha256": "1681eb90e49f4f229afe89bb75ff1738b7503907a52cd174e8b3d64b120082f4",
"routes": [
{
"circuit": 1,
"pathLengthMm": 48.72671365390632,
"minimumSampledRadiusMm": 0.5483013883766715,
"requiredMinimumRadiusMm": 4.25,
"rootStraightMm": 4.5,
"minimumFactoryLeadMm": 35,
"terminationAllowanceMm": 4,
"minimumSlackMm": 5,
"shortLeadFits": false
},
{
"circuit": 2,
"pathLengthMm": 47.93678550572911,
"minimumSampledRadiusMm": 0.7427120206056765,
"requiredMinimumRadiusMm": 4.25,
"rootStraightMm": 4.5,
"minimumFactoryLeadMm": 35,
"terminationAllowanceMm": 4,
"minimumSlackMm": 5,
"shortLeadFits": false
}
],
"bodyConflicts": [],
"probeConflicts": [
{
"part": "Sensor.Lead.1",
"reference": "TP12"
},
{
"part": "Sensor.Lead.2",
"reference": "TP13"
}
],
"sensorCaseNominalSideGapMm": 0.1,
"sensorTopToSinkEnvelopeGapMm": 0.14,
"limits": [
"Maximum cylindrical body envelope is not exact manufacturer CAD.",
"Case edge contact and adhesive are unqualified; sensor must track metal case rather than airflow or plastic temperature.",
"Sensor coating must not be compressed; compatibility/strain relief remain unresolved.",
"Short 40 +/-5 mm leads may fail required route plus slack; do not splice or trim without a reviewed harness design.",
"No checks against detailed heatsink relief, clamp, mating tool or existing fan wires.",
"No change to formal board, BOM, firmware, calibration or acceptance."
]
}